You are here:

M2A-XL Stand Alone Transmitter, Explosion Proof

Get A Quote

The RKI M2A-XL is a state-of-the-art transmitter that can operate as an independent, stand-alone monitor or as part of an integrated system.

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or email sales@afcintl.com

Description

Description

The RKI M2A-XL is a state of the art transmitter that can operate as an independent, stand-alone monitor or as part of an integrated system. The M2A-XL connects with an analog or digital signal to virtually any controller, PLC, or DCS. Setup procedures are simplified with user friendly push buttons and OLED menus. It utilizes a magnetic wand technique for performing non-intrusive calibration. The M2A-XL provides an automatic zero drift correction feature, which results in more stable readings and reduces the need for adjustments due to sensor aging.

The housing of the M2A-XL does not need to be opened for zeroing or calibration, making it unnecessary to declassify the area for routine maintenance. It is designed so that a complete field calibration can be performed by one person. Sensor construction is rated Class I, Div 1 Groups B, C, D for flammables, CO, H2S, O2, and CO2, and Class I, Div 2 for all other toxic gases.

The transmitter provides a 4-20 mA output in addition to a Modbus digital output. It also has two levels of alarms with relays, plus a fail alarm with relay. A digital display of the gas concentration, as well as alarm and status lights, can be viewed through the front window.

The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in Class I, Div 2 hazardous locations. Sensors available for Ammonia (NH3), Arsine (AsH3), Chlorine (Cl2), Chlorine Dioxide (ClO2), Hydrogen Cyanide (HCN), Phosphine (PH3), Nitrogen Dioxide (NO2), and Sulfur Dioxide (SO2).

The M2A-XL Stand Alone Transmitter represents the latest leading edge technology in sensor / transmitters today.

 

 

Features

  • Operates with or without a controller
  • Direct digital readout with OLED cold temperature display
  • Available gases include
    â—¦ LEL, O2, H2S, CO, CO2, and 100% Vol CH4
    â—¦ Toxic gases include NH3, AsH3, Cl2, ClO2, HCN, NO2, & SO2
  • Infrared sensor for combustibles and CO2
  • 4-20 mA & digital Modbus outputs standard
  • 2 fully programmable alarm relays & fail relay
  • Non-intrusive calibration via magnetic wand
  • Explosion proof construction
  • Patented water repellent sensor cover
  • User friendly setup, push buttons & OLED menus
  • Long-life sensors (2 + years typical)

Specifications

Range Sensor dependent
Response Time Sensor dependent
Accuracy Generally ±10% of value, but limited by available calibration gas accuracy
Electronic Repeatability ±1% of full scale
Electronic Linearity ±5-10% of full scale, depends on sensor
Alarm Settings Two fully programmable alarm set points, increasing, decreasing, latching, self-resetting on delays, off delays, normally energized or de-energized
Alarms Visual LEDs, Alarm 1: amber, Alarm 2: red, Fail: red
Relays 5 Amp form ‘C’ contacts for alarm 1, 2 and fail
Power 10 VDC – 30VDC
Outputs Analog: Linear 4-20 mA signal, into 1000 ohms impedance max (24 DC), 0-500 ohms max (12 VDC) corresponding to 0-full scale
Digital: Modbus RTU output std, fully configurable, 2-wire RS-485, 1200 to 19.2 k Baud
Display OLED display, 8 characters per line, 2 lines for gas concentration readout, plus user-friendly calibration and set up
Housing NEMA 4X, explosion proof, watertight, cast aluminum with o-ring seal and epoxy powder coating
Controls Magnet used for calibration functions, calibrates without opening the housing, internal push-button controls also available
Enclosure Explosion Proof: Class 1, Div 1, Groups B, C, D
Non-Explosion Proof: Class I, Div 2, Groups B, C, D
Size 6.2″ x 5.66″ x 4.86″
Operating Temperature -4°F to 104°F up to 122°F, Sensor dependant
Warranty 1 year

Sensor Specifications

Gas
Range
Resolution
Ammonia
0-75.0 ppm
0.1 ppm
0-100 ppm
1 ppm
0-200 ppm
1 ppm
0-500 ppm
1 ppm
Arsine
0-1.50 ppm
0.1 ppm
Carbon Monoxide
0-300 ppm
1 ppm
Chlorine 0-3.00 ppm 0.01 ppm
0-5.00 ppm
0.01 ppm
0-10.0 ppm 0.1 ppm
Chlorine Dioxide
0-1.00 ppm
0.01 ppm
0-1.00 ppm
0.01 ppm
0-3.00 ppm
0.01 ppm
0-5.00 ppm
0.01 ppm
Combustibles* 0-100% LEL 1% LEL
0-9,000 ppm
20 ppm
Hydrocarbons*
0-100% LEL
1% LEL
Hydrogen Cyanide
0-15.0 ppm
0.1 ppm
Hydrogen Sulfide
0-100 ppm
1 ppm
Methane*
0-100% LEL
1% LEL
Nitrogen Dioxide 0-15.0 ppm
0.1 ppm
Oxygen
0-15% Vol
0.1% Vol
Phosphine
0-1.00 ppm
0.01 ppm
Sulfur Dioxide
0-6.00ppm
0.01 ppm

(*) Explosion Proof Enclosure