IAQ Monitors


IAQ Monitors

Poor indoor air quality is said to effect over 20% of all commercial buildings. Indoor air pollution has been listed as the number one environmental risk. Typical problems include carbon dioxide, formaldehyde, temperature, high humidity, particulates, volatiles organics, microbiological materials or tobacco smoke.

4
Yes
None
1
60
Search...
/gas-detection-instruments/gas-detectors/iaq-monitors/
Thumbnail
Sort By:

Categories:

Tags:

Manufacturer:

Model:

Short Description:

' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series D12 gas transmitter product line has been expanded. Now available in this versatile package is an LEL transmitter utilizing an Infrared sensor that resists the poisoning problems inherent in catalytic bead sensors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series PQ45 is the answer to the need for a rugged field deployed package capable of measuring and recording water quality data in a variety of operating environments.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Allegro's Air Filtration Panels convert shop air used for pneumatic tools and equipment to clean breathable air.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Area monitoring reinvented. That's what Draeger's X-zone 5500 brings to a worksite: a safer, more effective way to monitor for hazardous gases. In combination with the Draeger X-am 5000, 5100 or 5600 gas detection instruments, the X-zone 5500 can be used for the measurement of up to six gases and extends the range of your portable gas detection technology.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Breathe cool, stay safe: Draeger X-plore 1750 and 1760 is Draeger's new generation particle filtering face piece respirators, coming with distinct improvements in comfort and protection.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Combining versatility, ease of use and the latest breathing apparatus design, Draeger's PAS Micro is among the most technologically advanced, short duration emergency escape units available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Draeger's PAS Colt combines versatility, ease of use and the latest in breathing apparatus design. It is among the most technologically advanced, short duration emergency escape unit available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ER2000 Escape Respirator is a hood style full face respirator that provides respiratory protection from Nuclear, Biological and Chemical (NBC) warfare agents as well as Toxic Industrial Materials (TIM's).

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

FMC 2000 is a multi-channel controller with built in modem designed for integration with Rae Systems' wireless mesh network products. It is simple to install and operate, versatile, and dependable.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

For qualitative fit testing of air purifying respirators this Smoke Test Kit offers everything needed for meeting OSHA's protocol for fit testing with smoke.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Perfect for storing APR's cartridges and other respirator accessories such as fit testing kits, storage bags and cleaning supplies.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' Hand pump if for use with Rae's line of gas detection tubes.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' MultiRae Lite is a perfect wireless monitoring solution for personal protection. It can monitor up to six gases and thrives in confined space entry situations. This tool comes in either with an internal pump or diffusion monitor and is compatible with more than 30 sensor options allowing it to fully meet the monitoring requirements of any application.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' large selection of colorimetric gas detection tubes offer quick, on the spot measurements of a wide range of toxic and combustible gases and vapors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' ppbRae 3000 is a state of the art VOC gas detector for monitoring at the parts per billion (ppb) level. This device uses a new generation of photo ionization detector (PID) and features both temperature and humidity compensation for improved accuracy. It includes built in correction factors for over 200 compounds and is suitable for use in any hazardous environment.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Casella dBadge2 Noise Dosimeter keeps all the great attributes of the original dBadge but adds incredible features you won't want to do without!

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Draeger single cartridge system keeps cartridges and filters out of the wearer's line of vision without sacrificing service life or breathing comfort. the threaded adapter on the cartridges makes change out simple, quick and sure.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The GfG G460 combustible gas detector is the world's most advanced multi-sensor atmospheric monitor. The durable G460 continuously measures and displays readings for up to six gases at the same time.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae 2000 is no longer available. The MiniRae 3000+ has replaced the MiniRae 2000. The MiniRae 3000+ is Rae Systems most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae Lite from Rae Systems is the most reliable handheld portable volatile organic compound (VOC) monitor on the market. Its photo ionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for application ranging from environmental to construction.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Rae Systems MultiRae Pro is the industry's first wireless multi threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs), toxic, combustible gases and oxygen with Man Down Alarm functionality in one highly portable instrument.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The ToxiRae Pro is the world's first wireless personal monitor for toxic gases and oxygen. The Rae Systems ToxiRae Pro takes worker protection to the next level by providing safety professionals wireless access to real time instrument readings and alarm status (including man down alarm) from any location for better visibility and faster response.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The use of ozone gas is increasing rapidly in a wide variety of applications, such as water treatment, odor control and food processing. ATI's Model A23-14 is a portable generator designed to produce an ozone gas concentration below 1 ppm.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This Point of Attachment (POA) Air Control System connects to any breathing air source. It's housed in a Pelican carry case that can be wall mounted and includes an adjustable pressure regulator, pressure gauge and a pressure relief valve.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This heat stress meter features bright multi-color LCD backlights corresponding to OSHA's heat stress alert levels.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This unique sound meter enables remote sound level readings using a detachable probe. It features an RS232 computer interface, AC output and a coiled probe that extends to 9'.

' class='jquery-prod-cf-value' />
G110 CO2 Analyzer with 0-100% CO2 Range
The G110 infrared portable CO2 gas analyzer has been designed to monitor carbon dioxide for multiple applications including the brewing industry. This unit has been developed to incorporate the latest technology and specification requirements, that provide the user with a fast, simple to use analyzer. In addition to CO2 infrared based detection and measurement, each model offers optional sensors including oxygen, temperature and relative humidity. Infrared sensor technology is ideal for carbon dioxide detection as it offers accurate, reliable measurement with low maintenance costs.

Features

  • Available in 4 versions, CO2 only, CO2 with oxygen, CO2 rH probe and CO2, O2 with rH probe
  • Optional add on are a temperature probe and data download kit
  • Improved menu driven software with intuitive operation and interactive screen prompts
  • Large data storage – 1,000 data set capacity with optional USB download software kit
  • High capacity lithium-ion battery for up to 10 hours of runtime
  • Ergonomically designed case with integral stand and rubber sides for robustness
  • Stable infrared (IR) CO2 sensor provides better accuracy
  • Internal pump draws 100 cc/minute for fast response
  • Large backlit LCD display with graphic icons is easy to read in any lighting condition
  • User adjustable settings for alarm and calibration setpoints via keypad (no PC required)
  • User ID code setting for security and record keeping
  • Large data storage or 1,000 readings and 270 events viewable on screen
  • User friendly software and USB data download for data graphing and trend analysis (optional kit)
  • Integrated Nafion tube for humidity reduction of sample gas ensures stable readings
  • All models have 2 temperature probe ports for T1-T2 calculation

Specifications

Range CO2: 0-100% O2, optional: 0-100%
Resolution 0.01% increments
Response Time CO2: T90<20 seconds O2: T90<60 seconds
Accuracy CO2: ±1% of range O2: ±1.0% of range
Temperature, Optional Up to 2 readings using optional probes 32°F to 122%
Humidity, Optional rH probe 0-100% rH, non-condensing
Pump Flow 100 cc/min typically
Data Storage 1,000 reading + 270 events
Data Download USB type B mini connector, HD device class
Power Source Lithium-Ion rechargeable battery
Charger Universal AC charger, 120-240 VAC
Battery Life 10 hours, 8 hours with pump
Charge Time 3 hours
Alternative Power USB connector to PC
Operating Temperature 41°F to 104°F
Relative Humidity 0 to 95%
Dimensions 6.5″L x 4″W x 2.2″H
Weight 18 ounces
Construction High impact ABS Case

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
G110 Infrared CO2 Monitor includes Pump
G110-00N
G110 Infrared CO2 Monitor with Oxygen Sensor and Pump
G110-10N
G110 Infrared CO2 Monitor with Oxygen Sensor , rH Sensor and Pump
G110-11N
G110 Infrared CO2 Monitor with rH Sensor & Pump
G110-01N
Temperature Probe, 5mm tip G-TP5
Temperature Probe, 100mm SS tip G-TP100
Download Software for Managing Data G-SW
Relative Humidity Probe, 15mm diameter G-RH15
Relative Humidity Probe, 4mm diameter G-RH4
Soda Lime Kit for Zeroing, tubing plus 3 filters G-SLKIT
Hard Sided Case G-HCASE
Filter, pk/10 G-PTFE
Sample Tube Kit with Filter G-TKIT
USB Communication Cable G-USB
Calibration Kit includes regulator, tubing & filter, no gas G-CALKIT
Moisture Trap, pk/2 G-MT

Downloads

G110 Infrared CO2 Literature Viasensor was acquired by QED Environmental Systems.
G150 CO2 Infrared Portable Gas Detector

The G150 CO2 gas detector is ideal for indoor air quality measurements, ventilation verification and process operations. The G150 infrared portable CO2 gas analyzer has improved software, the latest battery technology, USB data communications and flexible sensor options.In addition to carbon dioxide infrared based detection and measurement, each model offers optional sensors including oxygen, temperature and relative humidity. Infrared sensor technology is ideal for carbon dioxide detection as it offers accurate, reliable measurement with low maintenance costs.

Features

  • Available in 4 versions, CO2 only, CO2 with oxygen, CO2 with oxygen and rH and CO2 and rH
  • Optional add on are a temperature probe and data download kit
  • Improved menu driven software with intuitive operation and interactive screen prompts
  • Large data storage – 1,000 data set capacity with optional USB download software kit
  • High capacity lithium-ion battery for up to 10 hours of runtime
  • Ergonomically designed case with integral stand and rubber sides for robustness
  • Stable infrared (IR) CO2 sensor provides better accuracy
  • Internal pump draws 100 cc/minute for fast response
  • Large backlit LCD display with graphic icons is easy to read in any lighting condition
  • User adjustable settings for alarm and calibration setpoints via keypad (no PC required)
  • User ID code setting for security and record keeping
  • Large data storage or 1,000 readings and 270 events viewable on screen
  • User friendly software and USB data download for data graphing and trend analysis (optional kit)
  • Integrated Nafion tube for humidity reduction of sample gas ensures stable readings
  • All models have 2 temperature probe ports for T1-T2 calculation

Specifications

Range CO2: 0-10,000 ppm
O2, Optional: 0-100%
Resolution CO2: 5 ppm increments
O2: 0.1% increments
Response Time CO2: T90<20 seconds
O2: T90<60 seconds
Accuracy CO2: ±1% of range, +2% of reading
O2: ±1.0% full scale at constant temperature & pressure
Temperature, Optional Up to 2 readings using optional probes
32ºF to 122º
Humidity, Optional rH probe 0-100% rH, non-condensing
Pump Flow 100 cc/min typically
Data Storage 1000 reading + 270 events
Data Download USB type B mini connector, HD device class
Power Source Lithium-Ion rechargeable battery
Charger Universal AC charger, 120-240 VAC
Battery Life 10 hours, 8 hours with pump
Charge Time 3 hours
Alternative Power USB connector to PC
Operating Temperature 41°F to 104°F
Relative Humidity 0 to 95%
Dimensions 6.5″L x 4″W x 2.5″H
Weight 18 ounces
Construction High impact ABS Case

Ordering Information

Each G150 Infrared carbon dioxide monitor includes battery, charger, sample tubing, dust filter, operating instructions. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
G150 Infrared CO2 Monitor includes Pump, 0-10,000 ppm CO2
G150-00N
G150 Infrared CO2 Monitor with Oxygen Sensor and Pump, 0-10,000 ppm CO2
G150-10N
G150 Infrared CO2 Monitor with Oxygen, rH Sensor and Pump, 0-10,000% CO2
G150-11N
G150 Infrared CO2 Monitor with rH/T Probe & Pump, 0-10,000% CO2
G150-01N

Accessory Ordering Information

Description
Catalog No.
Temperature Probe, 5mm tip G-TP5
Temperature Probe, 100mm SS tip G-TP100
Download Software for Managing Data G-SW
Relative Humidity Probe, 15mm diameter G-RH15
Relative Humidity Probe, 4mm diameter G-RH4
Soda Lime Kit for Zeroing, tubing plus 3 filters G-SLKIT
Hard Sided Case G-HCASE
Filter, pk/10 G-PTFE
Sample Tube Kit with Filter G-TKIT
USB Communication Cable G-USB
Calibration Kit includes regulator, tubing & filter, no gas G-CALKIT
Moisture Trap, pk/2 G-MT

Downloads

G150 Infrared CO2 Literature
Viasensor was acquired by QED Environmental Systems.

G100 CO2 Infrared Portable Gas Analyzer
The G100 CO2 Infrared Portable Gas Analyzer was specifically designed to monitor carbon dioxide for the verification of incubators in IVF, medical, research and other pharmaceutical markets. This unit has been developed to incorporate the latest technology and specification requirements. This provides the user with a fast, simple to use and accurate piece of laboratory equipment. In addition to CO2 infrared based detection and measurement, each portable model offers optional sensors including oxygen, temperature and relative humidity. Infrared sensor technology is ideal for carbon dioxide detection as it offers accurate, reliable measurement with low maintenance costs.

Features

  • Available in 4 versions, CO2 only, CO2 with oxygen and CO2 with rH probe and CO2 with oxygen and rH probe
  • Optional add on are a temperature probe and data download kit. Improved menu driven software with intuitive operation and interactive screen prompts
  • Built in gas moisture removal
  • Large data storage – 1,000 data set capacity with optional USB download software kit
  • High capacity lithium-ion battery for up to 10 hours of runtime
  • Ergonomically designed case with integral stand and rubber sides for robustness
  • Stable infrared (IR) CO2 sensor provides better accuracy
  • Internal pump draws 100 cc/minute for fast response
  • Large backlit LCD display with graphic icons is easy to read in any lighting condition
  • User adjustable settings for alarm and calibration setpoints via keypad (no PC required)
  • User ID code setting for security and record keeping
  • Large data storage or 1,000 readings and 270 events viewable on screen
  • User friendly software and USB data download for data graphing and trend analysis (optional kit)
  • Integrated Nafion tube for humidity reduction of sample gas ensures stable readings
  • All models have 2 temperature probe ports for T1-T2 calculation

Specifications

Range CO2: 0-20% O2, optional: 0-100%
Resolution 0.01% increments
Response Time CO2: T90<20 seconds O2: T90<60 seconds
Accuracy CO2: ±1% of range O2: ± 1% of range
Temperature, Optional Up to 2 readings using optional probe, 32°F to 122%
Humidity, Optional rH probe 0-100% rH, non-condensing
Pump Flow 100 cc/min typically
Data Storage 1000 reading + 270 events
Data Download USB type B mini connector, HD device class
Power Source Lithium-Ion rechargeable battery
Charger Universal AC charger, 120-240 VAC
Battery Life 10 hours, 8 hours with pump
Charge Time 3 hours
Alternative Power USB connector to PC
Operating Temperature 32°F to 122°F
Relative Humidity 0 to 95%
Dimensions 6.5″L x 4″W x 2.2″H
Weight 18 ounces
Construction High impact ABS Case

Ordering Information

Each G100 CO2 monitor includes battery, charger, sample tubing, dust filter, operating instructions. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
G100 Kit includes detector, sample tube, manual, battery charger, case and temperature probe, 5mm tip G100-00PKG
G100 Kit includes detector with O2 sensor, sample tube, manual, battery charger and temperature probe, 5mm tip G100-10PKG
G100 Infrared CO2 Monitor includes Pump G100-00N
G100 Infrared CO2 Monitor with Oxygen and Pump
G100-10N
G100 Infrared CO2 Monitor with Oxygen, RH Sensor and Pump
G100-11N
G100 Infrared CO2 Monitor with RH Sensor & Pump
G100-01N
Temperature Probe, 5mm tip G-TP5
Temperature Probe, 100mm SS tip G-TP100
Download Software for Data Management G-SW
Relative Humidity Probe, 15mm diameter G-RH15
Relative Humidity Probe, 4mm diameter G-RH4
Soda Lime Kit for Zeroing, tubing plus 3 filters G-SLKIT
Hard Sided Carrying Case G-HCASE
Filter, pk/10 G-PTFE
Sample Tube Kit with Filter G-TKIT
USB Communication Cable G-USB
Calibration Kit includes regulator, tubing and filter, no gas G-CALKIT
Moisture Trap Filter, pk/2 G-MT

Downloads

G100 CO2 Gas Analyzer Literature Viasensor was acquired by QED Environmental Systems.
Indoor Air Quality Wall Monitor
Poor air quality may cause tiredness, inability to concentrate and even illness (i.e. Sick Building Syndrome) This Indoor Air Quality Wall Monitor is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of carbon dioxide such as offices, factories, classrooms, hospitals and hotels. This monitors displays readings on a bright green LED display with 2½” high CO2 digits. It also indicates general CO2 levels with green (good), yellow( fair and red (poor) LED lights. The user may set a maximum CO2 audible alarm and adjust temperature and RH readings to match any standard. The Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long term accuracy, stability and reliability. Each unit includes an AC adapter and will stand on a desk top or can be wall mounted. 12″ x 8½” x 2″, 2.9 pounds

Measures

  • Carbon dioxide
  • Humidity
  • Air Temperature

Specifications

Carbon Dioxide Sensor
Measuring Range 0 to 9,999 ppm
Resolution 1 ppm
Accuracy ±30 ppm, ± 3% of reading
Relative Humidity Sensor
Measuring Range 0 to 99.9% RH
Resolution 0.1
Accuracy at +25°C ±3% @ 25°C & 10-90% rH, otherwise ±5%
Temperature Sensor
Measuring Range -40 – 85°C, 32-122°F
Resolution 0.1
Accuracy 0.6°C

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Datalogging Indoor Air Quality Monitor
800051
Indoor Air Quality Monitor

This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. Poor air quality may cause tiredness, inability to concentrate, and even illness (ie Sick Building Syndrome). This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. The same measurement parameters can also be used to test air from HVAC equipment. Backlit simultaneous display of CO2 level, humidly and air temperature or the user may choose a rotating display of dew point and wet bulb temperature instead of air temperature. This detector also calculates TWA (Time Weighted Average) and STEL (Short Term Exposure Limit). Features simple user calibration of carbon dioxide and humidity. This meter includes an audible CO2 threshold alarms, min/max, ave, hold and a computer interface. The NDIR sensor technology ensures long term accuracy, stability and reliability. Each unit includes a hard carrying case with 4AA batteries.

Features

  • Carbon dioxide
  • Humidity
  • Dew Point
  • Air Temperature
  • Wet Bulb Temperature

Specifications

Carbon Dioxide Sensor
Measuring Range 0 to 5,000 ppm
Resolution 1 ppm
Accuracy ±30 ppm, ± 5% of reading
Relative Humidity Sensor
Measuring Range 0 to 100% RH
Resolution 0.1
Accuracy at +25°C ±3% (10-90%)
±5% otherwise
Temperature Sensor
Measuring Range -10 – 60°C,
14-140°F
Resolution 0.1
Accuracy 0.6°C,
0.9°F
Dew Point
Measuring Range -13.3-60°C,
8-140°F
Resolution 0.1
Wet Bulb
Measuring Range -73.4 – 60°C,
-100 – 140°F
Resolution 0.1

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Sper IAQ Monitor
800046
AC Adapter
840027
Data Acquisition Software
840052
RS232 Cable
840054
Water Resistant Instrument Pouch
840090
75% Calibration Salt Solution
860029
33% Calibration Salt Solution
860019

Downloads

IAQ Detector literature

Large Display Indoor Air Quality Wall Monitor
Poor air quality may cause tiredness, inability to concentrate and even illness (i.e. Sick Building Syndrome). This IAQ Wall Monitor is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of carbon dioxide such as offices, factories, classrooms, hospitals and hotels. This unit recalls min/max CO2 levels and provides visual alarms for maximum CO2 threshold. The Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long term accuracy, stability and reliability. Each unit includes an AC adapter and will stand on a desk top or can be wall mounted. The datalogging version also records up to 32,000 data points that can downloaded using the USB cable and software included. 12″ x 8½” x 2″, 2.9 pounds

Measures

  • Carbon dioxide
  • Humidity
  • Air Temperature

Specifications

Carbon Dioxide Sensor
Measuring Range 0 to 9,999 ppm
Resolution 1 ppm
Accuracy ±75 ppm, ± 5% of reading
Relative Humidity Sensor
Measuring Range 10 to 90% RH
Resolution 0.1
Accuracy at +25°C ±5% @ 25°C & 10-90% rH, otherwise ±7%
Temperature Sensor
Measuring Range -10 – 50°C, -14-122°F
Resolution 0.1
Accuracy 0.6°C

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
IAQ Wall Monitor
800048
Datalogging IAQ Monitor 800049
Datalogging Indoor Air Quality Monitor
This Datalogging Indoor Air Quality Monitor is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. Poor air quality may cause tiredness, inability to concentrate, and even illness (ie Sick Building Syndrome). The same measurement parameters can also be used to test air from HVAC equipment. Recalls the maximum and minimum CO2 readings and has a user selectable audible maximum alarm. Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long term accuracy, stability and reliability. Calibrates to air and has a hold function. Records up to 32,000 data points of temperature RH and CO2 that can be downloaded using a a USB cable and software (included). Each detector includes a tripod screw, soft carrying case, 6 x AAA batteries, AC adapter, USB computer cable and software.

Measures

  • Carbon dioxide
  • Humidity
  • Dew Point
  • Air Temperature
  • Wet Bulb Temperature

Specifications

Carbon Dioxide Sensor
Measuring Range 0 to 9,999 ppm
Resolution 1 ppm
Accuracy ±75 ppm, ± 5% of reading
Relative Humidity Sensor
Measuring Range 10 to 90% RH
Resolution 0.1
Accuracy at +25°C ±5%
Temperature Sensor
Measuring Range -10 – 50°C, 14-122°F
Resolution 0.1
Accuracy 0.1°C
Dew Point
Measuring Range -13.3-60°C, 8-140°F
Resolution 0.1
Wet Bulb
Measuring Range -73.4 – 60°C, -100 – 140°F
Resolution 0.1

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Datalogging Indoor Air Quality Monitor
800050
G110 CO2 Analyzer with 0-100% CO2 Range
The G110 infrared portable CO2 gas analyzer has been designed to monitor carbon dioxide for multiple applications including the brewing industry. This unit has been developed to incorporate the latest technology and specification requirements, that provide the user with a fast, simple to use analyzer. In addition to CO2 infrared based detection and measurement, each model offers optional sensors including oxygen, temperature and relative humidity. Infrared sensor technology is ideal for carbon dioxide detection as it offers accurate, reliable measurement with low maintenance costs. Features Available in 4 versions, CO2 only, CO2 with oxygen, CO2 rH probe and CO2, O2 with rH probe Optional add on are a temperature probe and data download kit Improved menu driven software with intuitive operation and interactive screen prompts Large data storage – 1,000 data set capacity with optional USB download software kit High capacity lithium-ion battery for up to 10 hours of runtime Ergonomically designed case with integral stand and rubber sides for robustness Stable infrared (IR) CO2 sensor provides better accuracy Internal pump draws 100 cc/minute for fast response Large backlit LCD display with graphic icons is easy to read in any lighting condition User adjustable settings for alarm and calibration setpoints via keypad (no PC required) User ID code setting for security and record keeping Large data storage or 1,000 readings and 270 events viewable on screen User friendly software and USB data download for data graphing and trend analysis (optional kit) Integrated Nafion tube for humidity reduction of sample gas ensures stable readings All models have 2 temperature probe ports for T1-T2 calculation Specifications Range CO2: 0-100% O2, optional: 0-100% Resolution 0.01% increments Response Time CO2: T90<20 seconds O2: T90<60 seconds Accuracy CO2: ±1% of range O2: ±1.0% of range Temperature, Optional Up to 2 readings using optional probes 32°F to 122% Humidity, Optional rH probe 0-100% rH, non-condensing Pump Flow 100 cc/min typically Data Storage 1,000 reading + 270 events Data Download USB type B mini connector, HD device class Power Source Lithium-Ion rechargeable battery Charger Universal AC charger, 120-240 VAC Battery Life 10 hours, 8 hours with pump Charge Time 3 hours Alternative Power USB connector to PC Operating Temperature 41°F to 104°F Relative Humidity 0 to 95% Dimensions 6.5″L x 4″W x 2.2″H Weight 18 ounces Construction High impact ABS Case Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com Description Catalog No. G110 Infrared CO2 Monitor includes Pump G110-00N G110 Infrared CO2 Monitor with Oxygen Sensor and Pump G110-10N G110 Infrared CO2 Monitor with Oxygen Sensor , rH Sensor and Pump G110-11N G110 Infrared CO2 Monitor with rH Sensor & Pump G110-01N Temperature Probe, 5mm tip G-TP5 Temperature Probe, 100mm SS tip G-TP100 Download Software for Managing Data G-SW Relative Humidity Probe, 15mm diameter G-RH15 Relative Humidity Probe, 4mm diameter G-RH4 Soda Lime Kit for Zeroing, tubing plus 3 filters G-SLKIT Hard Sided Case G-HCASE Filter, pk/10 G-PTFE Sample Tube Kit with Filter G-TKIT USB Communication Cable G-USB Calibration Kit includes regulator, tubing & filter, no gas G-CALKIT Moisture Trap, pk/2 G-MT Downloads G110 Infrared CO2 Literature Viasensor was acquired by QED Environmental Systems.
Manufacturer:
Brand:
Model:
Short Description:
G150 CO2 Infrared Portable Gas Detector
The G150 CO2 gas detector is ideal for indoor air quality measurements, ventilation verification and process operations. The G150 infrared portable CO2 gas analyzer has improved software, the latest battery technology, USB data communications and flexible sensor options.In addition to carbon dioxide infrared based detection and measurement, each model offers optional sensors including oxygen, temperature and relative humidity. Infrared sensor technology is ideal for carbon dioxide detection as it offers accurate, reliable measurement with low maintenance costs. Features Available in 4 versions, CO2 only, CO2 with oxygen, CO2 with oxygen and rH and CO2 and rH Optional add on are a temperature probe and data download kit Improved menu driven software with intuitive operation and interactive screen prompts Large data storage – 1,000 data set capacity with optional USB download software kit High capacity lithium-ion battery for up to 10 hours of runtime Ergonomically designed case with integral stand and rubber sides for robustness Stable infrared (IR) CO2 sensor provides better accuracy Internal pump draws 100 cc/minute for fast response Large backlit LCD display with graphic icons is easy to read in any lighting condition User adjustable settings for alarm and calibration setpoints via keypad (no PC required) User ID code setting for security and record keeping Large data storage or 1,000 readings and 270 events viewable on screen User friendly software and USB data download for data graphing and trend analysis (optional kit) Integrated Nafion tube for humidity reduction of sample gas ensures stable readings All models have 2 temperature probe ports for T1-T2 calculation Specifications Range CO2: 0-10,000 ppm O2, Optional: 0-100% Resolution CO2: 5 ppm increments O2: 0.1% increments Response Time CO2: T90<20 seconds O2: T90<60 seconds Accuracy CO2: ±1% of range, +2% of reading O2: ±1.0% full scale at constant temperature & pressure Temperature, Optional Up to 2 readings using optional probes 32ºF to 122º Humidity, Optional rH probe 0-100% rH, non-condensing Pump Flow 100 cc/min typically Data Storage 1000 reading + 270 events Data Download USB type B mini connector, HD device class Power Source Lithium-Ion rechargeable battery Charger Universal AC charger, 120-240 VAC Battery Life 10 hours, 8 hours with pump Charge Time 3 hours Alternative Power USB connector to PC Operating Temperature 41°F to 104°F Relative Humidity 0 to 95% Dimensions 6.5″L x 4″W x 2.5″H Weight 18 ounces Construction High impact ABS Case Ordering Information Each G150 Infrared carbon dioxide monitor includes battery, charger, sample tubing, dust filter, operating instructions. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com Description Catalog No. G150 Infrared CO2 Monitor includes Pump, 0-10,000 ppm CO2 G150-00N G150 Infrared CO2 Monitor with Oxygen Sensor and Pump, 0-10,000 ppm CO2 G150-10N G150 Infrared CO2 Monitor with Oxygen, rH Sensor and Pump, 0-10,000% CO2 G150-11N G150 Infrared CO2 Monitor with rH/T Probe & Pump, 0-10,000% CO2 G150-01N Accessory Ordering Information Description Catalog No. Temperature Probe, 5mm tip G-TP5 Temperature Probe, 100mm SS tip G-TP100 Download Software for Managing Data G-SW Relative Humidity Probe, 15mm diameter G-RH15 Relative Humidity Probe, 4mm diameter G-RH4 Soda Lime Kit for Zeroing, tubing plus 3 filters G-SLKIT Hard Sided Case G-HCASE Filter, pk/10 G-PTFE Sample Tube Kit with Filter G-TKIT USB Communication Cable G-USB Calibration Kit includes regulator, tubing & filter, no gas G-CALKIT Moisture Trap, pk/2 G-MT Downloads G150 Infrared CO2 Literature Viasensor was acquired by QED Environmental Systems.
Manufacturer: Viasensor-A QED Company
Brand: G150
Model: CO2 Single Gas Detector
Short Description:

The G150 CO2 gas detector is ideal for indoor air quality measurements, ventilation verification and process operations. The G150 infrared portable CO2 gas analyzer has improved software, the latest battery technology, USB data communications and flexible sensor options.

G100 CO2 Infrared Portable Gas Analyzer
The G100 CO2 Infrared Portable Gas Analyzer was specifically designed to monitor carbon dioxide for the verification of incubators in IVF, medical, research and other pharmaceutical markets. This unit has been developed to incorporate the latest technology and specification requirements. This provides the user with a fast, simple to use and accurate piece of laboratory equipment. In addition to CO2 infrared based detection and measurement, each portable model offers optional sensors including oxygen, temperature and relative humidity. Infrared sensor technology is ideal for carbon dioxide detection as it offers accurate, reliable measurement with low maintenance costs. Features Available in 4 versions, CO2 only, CO2 with oxygen and CO2 with rH probe and CO2 with oxygen and rH probe Optional add on are a temperature probe and data download kit. Improved menu driven software with intuitive operation and interactive screen prompts Built in gas moisture removal Large data storage – 1,000 data set capacity with optional USB download software kit High capacity lithium-ion battery for up to 10 hours of runtime Ergonomically designed case with integral stand and rubber sides for robustness Stable infrared (IR) CO2 sensor provides better accuracy Internal pump draws 100 cc/minute for fast response Large backlit LCD display with graphic icons is easy to read in any lighting condition User adjustable settings for alarm and calibration setpoints via keypad (no PC required) User ID code setting for security and record keeping Large data storage or 1,000 readings and 270 events viewable on screen User friendly software and USB data download for data graphing and trend analysis (optional kit) Integrated Nafion tube for humidity reduction of sample gas ensures stable readings All models have 2 temperature probe ports for T1-T2 calculation Specifications Range CO2: 0-20% O2, optional: 0-100% Resolution 0.01% increments Response Time CO2: T90<20 seconds O2: T90<60 seconds Accuracy CO2: ±1% of range O2: ± 1% of range Temperature, Optional Up to 2 readings using optional probe, 32°F to 122% Humidity, Optional rH probe 0-100% rH, non-condensing Pump Flow 100 cc/min typically Data Storage 1000 reading + 270 events Data Download USB type B mini connector, HD device class Power Source Lithium-Ion rechargeable battery Charger Universal AC charger, 120-240 VAC Battery Life 10 hours, 8 hours with pump Charge Time 3 hours Alternative Power USB connector to PC Operating Temperature 32°F to 122°F Relative Humidity 0 to 95% Dimensions 6.5″L x 4″W x 2.2″H Weight 18 ounces Construction High impact ABS Case Ordering Information Each G100 CO2 monitor includes battery, charger, sample tubing, dust filter, operating instructions. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com Description Catalog No. G100 Kit includes detector, sample tube, manual, battery charger, case and temperature probe, 5mm tip G100-00PKG G100 Kit includes detector with O2 sensor, sample tube, manual, battery charger and temperature probe, 5mm tip G100-10PKG G100 Infrared CO2 Monitor includes Pump G100-00N G100 Infrared CO2 Monitor with Oxygen and Pump G100-10N G100 Infrared CO2 Monitor with Oxygen, RH Sensor and Pump G100-11N G100 Infrared CO2 Monitor with RH Sensor & Pump G100-01N Temperature Probe, 5mm tip G-TP5 Temperature Probe, 100mm SS tip G-TP100 Download Software for Data Management G-SW Relative Humidity Probe, 15mm diameter G-RH15 Relative Humidity Probe, 4mm diameter G-RH4 Soda Lime Kit for Zeroing, tubing plus 3 filters G-SLKIT Hard Sided Carrying Case G-HCASE Filter, pk/10 G-PTFE Sample Tube Kit with Filter G-TKIT USB Communication Cable G-USB Calibration Kit includes regulator, tubing and filter, no gas G-CALKIT Moisture Trap Filter, pk/2 G-MT Downloads G100 CO2 Gas Analyzer Literature Viasensor was acquired by QED Environmental Systems.
Manufacturer:
Brand:
Model:
Short Description:
Indoor Air Quality Wall Monitor
Poor air quality may cause tiredness, inability to concentrate and even illness (i.e. Sick Building Syndrome) This Indoor Air Quality Wall Monitor is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of carbon dioxide such as offices, factories, classrooms, hospitals and hotels. This monitors displays readings on a bright green LED display with 2½” high CO2 digits. It also indicates general CO2 levels with green (good), yellow( fair and red (poor) LED lights. The user may set a maximum CO2 audible alarm and adjust temperature and RH readings to match any standard. The Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long term accuracy, stability and reliability. Each unit includes an AC adapter and will stand on a desk top or can be wall mounted. 12″ x 8½” x 2″, 2.9 pounds Measures Carbon dioxide Humidity Air Temperature Specifications Carbon Dioxide Sensor Measuring Range 0 to 9,999 ppm Resolution 1 ppm Accuracy ±30 ppm, ± 3% of reading Relative Humidity Sensor Measuring Range 0 to 99.9% RH Resolution 0.1 Accuracy at +25°C ±3% @ 25°C & 10-90% rH, otherwise ±5% Temperature Sensor Measuring Range -40 – 85°C, 32-122°F Resolution 0.1 Accuracy 0.6°C Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Datalogging Indoor Air Quality Monitor 800051
Manufacturer:
Brand:
Model:
Short Description:
Indoor Air Quality Monitor
This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. Poor air quality may cause tiredness, inability to concentrate, and even illness (ie Sick Building Syndrome). This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. The same measurement parameters can also be used to test air from HVAC equipment. Backlit simultaneous display of CO2 level, humidly and air temperature or the user may choose a rotating display of dew point and wet bulb temperature instead of air temperature. This detector also calculates TWA (Time Weighted Average) and STEL (Short Term Exposure Limit). Features simple user calibration of carbon dioxide and humidity. This meter includes an audible CO2 threshold alarms, min/max, ave, hold and a computer interface. The NDIR sensor technology ensures long term accuracy, stability and reliability. Each unit includes a hard carrying case with 4AA batteries. Features Carbon dioxide Humidity Dew Point Air Temperature Wet Bulb Temperature Specifications Carbon Dioxide Sensor Measuring Range 0 to 5,000 ppm Resolution 1 ppm Accuracy ±30 ppm, ± 5% of reading Relative Humidity Sensor Measuring Range 0 to 100% RH Resolution 0.1 Accuracy at +25°C ±3% (10-90%) ±5% otherwise Temperature Sensor Measuring Range -10 – 60°C, 14-140°F Resolution 0.1 Accuracy 0.6°C, 0.9°F Dew Point Measuring Range -13.3-60°C, 8-140°F Resolution 0.1 Wet Bulb Measuring Range -73.4 – 60°C, -100 – 140°F Resolution 0.1 Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Sper IAQ Monitor 800046 AC Adapter 840027 Data Acquisition Software 840052 RS232 Cable 840054 Water Resistant Instrument Pouch 840090 75% Calibration Salt Solution 860029 33% Calibration Salt Solution 860019 Downloads IAQ Detector literature
Manufacturer: Sper Scientific Ltd
Brand: Indoor Air Quality
Model: IAQ Detector
Short Description:

This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels.

Large Display Indoor Air Quality Wall Monitor
Poor air quality may cause tiredness, inability to concentrate and even illness (i.e. Sick Building Syndrome). This IAQ Wall Monitor is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of carbon dioxide such as offices, factories, classrooms, hospitals and hotels. This unit recalls min/max CO2 levels and provides visual alarms for maximum CO2 threshold. The Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long term accuracy, stability and reliability. Each unit includes an AC adapter and will stand on a desk top or can be wall mounted. The datalogging version also records up to 32,000 data points that can downloaded using the USB cable and software included. 12″ x 8½” x 2″, 2.9 pounds Measures Carbon dioxide Humidity Air Temperature Specifications Carbon Dioxide Sensor Measuring Range 0 to 9,999 ppm Resolution 1 ppm Accuracy ±75 ppm, ± 5% of reading Relative Humidity Sensor Measuring Range 10 to 90% RH Resolution 0.1 Accuracy at +25°C ±5% @ 25°C & 10-90% rH, otherwise ±7% Temperature Sensor Measuring Range -10 – 50°C, -14-122°F Resolution 0.1 Accuracy 0.6°C Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. IAQ Wall Monitor 800048 Datalogging IAQ Monitor 800049
Manufacturer:
Brand:
Model:
Short Description:
Datalogging Indoor Air Quality Monitor
This Datalogging Indoor Air Quality Monitor is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. Poor air quality may cause tiredness, inability to concentrate, and even illness (ie Sick Building Syndrome). The same measurement parameters can also be used to test air from HVAC equipment. Recalls the maximum and minimum CO2 readings and has a user selectable audible maximum alarm. Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long term accuracy, stability and reliability. Calibrates to air and has a hold function. Records up to 32,000 data points of temperature RH and CO2 that can be downloaded using a a USB cable and software (included). Each detector includes a tripod screw, soft carrying case, 6 x AAA batteries, AC adapter, USB computer cable and software. Measures Carbon dioxide Humidity Dew Point Air Temperature Wet Bulb Temperature Specifications Carbon Dioxide Sensor Measuring Range 0 to 9,999 ppm Resolution 1 ppm Accuracy ±75 ppm, ± 5% of reading Relative Humidity Sensor Measuring Range 10 to 90% RH Resolution 0.1 Accuracy at +25°C ±5% Temperature Sensor Measuring Range -10 – 50°C, 14-122°F Resolution 0.1 Accuracy 0.1°C Dew Point Measuring Range -13.3-60°C, 8-140°F Resolution 0.1 Wet Bulb Measuring Range -73.4 – 60°C, -100 – 140°F Resolution 0.1 Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Datalogging Indoor Air Quality Monitor 800050
Manufacturer:
Brand:
Model:
Short Description: