Monitoring Badges


Hazardous Gas Monitoring Badges

Badges are an inexpensive, lightweight method of testing for toxic gases and vapors. They operate by diffusion exposure and no pump or active elements are required. A new badge is issued to each employee at the beginning of the work day and then easily disposed of.

AFC International, Inc. offers many types of badges for many types of contaminants. The following types of badges are available including Organic Vapor Monitoring badges utilizing charcoal & non-charcoal styles and passive badges from Morphix Technologies (K&M Environmental).

4
Yes
None
1
60
Search...
/gas-detection-instruments/monitoring-badges/
Thumbnail
Sort By:

Categories:

Tags:

Manufacturer:

Model:

Short Description:

' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series D12 gas transmitter product line has been expanded. Now available in this versatile package is an LEL transmitter utilizing an Infrared sensor that resists the poisoning problems inherent in catalytic bead sensors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series PQ45 is the answer to the need for a rugged field deployed package capable of measuring and recording water quality data in a variety of operating environments.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Allegro's Air Filtration Panels convert shop air used for pneumatic tools and equipment to clean breathable air.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Area monitoring reinvented. That's what Draeger's X-zone 5500 brings to a worksite: a safer, more effective way to monitor for hazardous gases. In combination with the Draeger X-am 5000, 5100 or 5600 gas detection instruments, the X-zone 5500 can be used for the measurement of up to six gases and extends the range of your portable gas detection technology.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Breathe cool, stay safe: Draeger X-plore 1750 and 1760 is Draeger's new generation particle filtering face piece respirators, coming with distinct improvements in comfort and protection.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Combining versatility, ease of use and the latest breathing apparatus design, Draeger's PAS Micro is among the most technologically advanced, short duration emergency escape units available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Draeger's PAS Colt combines versatility, ease of use and the latest in breathing apparatus design. It is among the most technologically advanced, short duration emergency escape unit available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ER2000 Escape Respirator is a hood style full face respirator that provides respiratory protection from Nuclear, Biological and Chemical (NBC) warfare agents as well as Toxic Industrial Materials (TIM's).

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

FMC 2000 is a multi-channel controller with built in modem designed for integration with Rae Systems' wireless mesh network products. It is simple to install and operate, versatile, and dependable.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

For qualitative fit testing of air purifying respirators this Smoke Test Kit offers everything needed for meeting OSHA's protocol for fit testing with smoke.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Perfect for storing APR's cartridges and other respirator accessories such as fit testing kits, storage bags and cleaning supplies.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' Hand pump if for use with Rae's line of gas detection tubes.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' MultiRae Lite is a perfect wireless monitoring solution for personal protection. It can monitor up to six gases and thrives in confined space entry situations. This tool comes in either with an internal pump or diffusion monitor and is compatible with more than 30 sensor options allowing it to fully meet the monitoring requirements of any application.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' large selection of colorimetric gas detection tubes offer quick, on the spot measurements of a wide range of toxic and combustible gases and vapors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' ppbRae 3000 is a state of the art VOC gas detector for monitoring at the parts per billion (ppb) level. This device uses a new generation of photo ionization detector (PID) and features both temperature and humidity compensation for improved accuracy. It includes built in correction factors for over 200 compounds and is suitable for use in any hazardous environment.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Casella dBadge2 Noise Dosimeter keeps all the great attributes of the original dBadge but adds incredible features you won't want to do without!

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Draeger single cartridge system keeps cartridges and filters out of the wearer's line of vision without sacrificing service life or breathing comfort. the threaded adapter on the cartridges makes change out simple, quick and sure.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The GfG G460 combustible gas detector is the world's most advanced multi-sensor atmospheric monitor. The durable G460 continuously measures and displays readings for up to six gases at the same time.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae 2000 is no longer available. The MiniRae 3000+ has replaced the MiniRae 2000. The MiniRae 3000+ is Rae Systems most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae Lite from Rae Systems is the most reliable handheld portable volatile organic compound (VOC) monitor on the market. Its photo ionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for application ranging from environmental to construction.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Rae Systems MultiRae Pro is the industry's first wireless multi threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs), toxic, combustible gases and oxygen with Man Down Alarm functionality in one highly portable instrument.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The ToxiRae Pro is the world's first wireless personal monitor for toxic gases and oxygen. The Rae Systems ToxiRae Pro takes worker protection to the next level by providing safety professionals wireless access to real time instrument readings and alarm status (including man down alarm) from any location for better visibility and faster response.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The use of ozone gas is increasing rapidly in a wide variety of applications, such as water treatment, odor control and food processing. ATI's Model A23-14 is a portable generator designed to produce an ozone gas concentration below 1 ppm.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This Point of Attachment (POA) Air Control System connects to any breathing air source. It's housed in a Pelican carry case that can be wall mounted and includes an adjustable pressure regulator, pressure gauge and a pressure relief valve.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This heat stress meter features bright multi-color LCD backlights corresponding to OSHA's heat stress alert levels.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This unique sound meter enables remote sound level readings using a detachable probe. It features an RS232 computer interface, AC output and a coiled probe that extends to 9'.

' class='jquery-prod-cf-value' />
Non-Charcoal Organic Vapor Monitoring Badges

Features

  • US Patented badges are analyzed using OSHA and NIOSH validated methods
  • Analyzed by an AIHA accredited lab
  • The lab is rated proficient in the NIOSH Proficiency Analysis Testing Program (PAT) for Analytes Tested.
  • All compounds listed for full analysis badge (OV-OOFull) will be tested for and reported if found
  • The same badge can be used for either TWA or STEL sampling
  • All inclusive price for badge, analysis and report
  • Report by fax, if requested, always by phone for high results
  • Summary reports available
  • Now ISO 9001:2015 certified

Compounds Detachable with the OV-OO Full Analysis Badge

Acetone 1,2-Dichloroethane Methyl Methacrylate
Acetonitrile 1,2-Dichloropropane Methyl-t butyl Ether
Acrylonitrile Dimethyl Formamide Methyl Styrene
Allyl Chloride Dimethyl Sulfoxide Methylene Chloride
Benzene Dioxane Nonane
1-Chloro-4-Benzene Ethyl Acetate Pentane
Benzyl Chloride Ethyl Alcohol Pentane Acetate
1,3-Butadiene Ethyl Benzene n-Pentanone
2-Butanone (MEK) Ethyl Ether Perchloroethylene
Butyl Acetate Ethyl Methacrylate n-Propyl Acetate
Butyl Cellosolve 4-Ethyltoluene Propyl Benzene
1-Butyl Alcohol Heptane n-Propyl Bromide
2-Butyl Alcohol 2-Heptanone Propylene Oxide
Carbon Tetrachloride Hexane Pyridine
Cellosolve 1-Hexanol Sytrene
Chlorobenzene Hexone (MIBK) Tetrahydrofuran
Chloroform Isopropyl Alcohol Toluene
Cyclohexane Isooctane 1,1,1-Trichloroethane
Cyclohexene d-Limonene Trichloroethylene
Cyclohexanol Methyl Acetate 1,2,4-Trimethylbenzene
Cyclohexanone Methyl Acrylate Vinyl Acetate
Dibromochloromethane Methyl Chloroform Vinyl Chloride
1,4-Dichlorobenzene 5-Methyl-2-Hexanone Xylene

Specifications

Accuracy Better than +25% at the 95% confidence interval
Limits of Detection Lower: Generally better than 1/10 of the PEL
Upper: At least 2 times PEL
Shelf Life 1 year at room temperature

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Badge
Catalog No.
Organic Vapor Badge, Full Analysis
OVF-00
a-Methyl Styrene OV-771
1,1,2-Trichloroethane OV-104
1,2,4-Trimethyl Benzene OV-107
1,3-Butadiene OV-12
2-Butanol OV-152
2-Butoxyethanol OV-16
2-Butoxyethytl Acetate OV-412
2-Mercaptoehtanol OV-579
2-Methoxyethylacetate OV-58
2-Phenoxyethanol OV-413
2-Propanol OV-86
Acetaldehydes OV-004
Acetic Acid OV-005
Acetone V OV-01
Acetonitrile OV-5
Acetophenone OV-052
Acrolein OV-055
Acrylamide OV-557
Acrylonitrile OV-06
Allyl Alcohol OV-07
Ammonia K-10
Amyl acetate OV-076
Aniline OV-077
BTEX OV-09
Benzene OV-08
Benzoic Acid OV-085
Benzyl Chloride V OV-10
Beta Mercaptoethanol OV-585
Biphenyl OV-11
BTEX + Saturated Hydrocarbons OV-095
Butyl Acetate OV-14
Butyl Alcohol OV-15
Butyl Cellosolve Acetate OV-15
Butylene Oxide OV-165
Carbon Disulfide OV-195
Carbon Tetrachloride OV-20
Cellosolve OV-22
Chlorobenzene OV-25
Chloroform OV-30
Collodion OV-31
Cumene OV-311
Cylcohexane OV-313
Cyclohexanol OV-314
Desflurane H-10-D
Dibromomethane OV-778
Dichloroethane OV-318
Dihloromethane OV-317
Diesel Fuel OV-33
Diethylaminoethanol OV-309
Diethylene Glycol OV-320
Dimethyl Formamide OV-326
Dimethyl Fumarate OV-330
Dimethyl Sulfoxide OV-325
Dimethylacetamide OV-328
Dioxane OV-319
Dipropylene Glycol Methyl Ether OV-333
Enflurane H-10-E
Epichlorohydrin OV-335
Ethyl Acetate OV-34
Ethyl Alcohol OV-35
Ethyl Benzene OV-37
Ethyl Ether OV-40
Ethyl Methacryalate OV-406
Ethylene Glycol OV-41
Ethylene Oxide E-50
Formaldehyde F-50
Formaldehyde & Glutaraldehyde FG-50
Formaldehyde & o-Phthalaldehyde FOP-50
Formaldehyde IAQ F-50I
Formaldehyde, Glutaraldehydel & o-Phthalaldehyde FGOP-50
Formamide OV-415
Full Scan Organic IAQ OVFI-00
Gasoline OV-45
Glutaraldehyde G-10
Glutaraldehyde & o-Phthalaldehyde GOP-10
Halogenated Anesthetic H-10-3
Halothane H-10-H
Heptane OV-50
Hexane OV-55
Hexylene Glycol OV-555
Hydrogen Peroxide HP-10
Hydrogen Sulfide HS-10
Hydroquinone OV-56
Isobutyl Alcohol OV-561
Isoflurane H-10-I
ISophorone OV-575
Isopropyl Alcohol OV-57
Jet Fuel OV-576
Kerosene OV-578
Limonene OV-577
m-Cresol OV-312
Mercury HG-10
Methyl (n-Amyl) Ketone OV-615
Methyl Alcohol OV-60
Methyl Bromide OV-595
Methyl Chloride OV-63
Methyl Chloroform OV-65
Methyl Ethyl Ketone OV-71
Methyl Ethyl Ketoxime OV-72
Methyl Iodide OV-755
Methyl Isobutyl Ketone OV-76
Methyl Methacrylate M-10
Methyl t-Butyl Ether OV-62
Methyelene Chloride OV-70
Metofane H-10-M
Mineral Spirits OV-77
Morpholine OV-772
n-Butyl Glycidal Ether OV-157
n-Butyl Mercapatan OV-166
n-Propyl Bromide OV-88
Naphtha OV-776
Naphthalene OV-775
Nitrilotriacetonitrile OV-779
Nitrobenzene OV-777
Nitrogen Dioxide NO-10
Nitromethane OV-780
Nitrous Oxide N-10
o-Phthalaldehyde OP-10
p-Dichlorobenzene OV-361
Pentane OV-78
Perchloroethylene OV-80
Petroleum Distillates OV-81
Phenol OV-85
Propargyl Alcohol OV-87
Propionic Acid OV-875
Propoxur OV-876
Propylene Glycol OV-885
Pyridine OV-91
Sevoflurane H-10-S
Stoddard Solvent OV-93
Styrene OV-95
Sulfur Dioxide SD-10
Tetrahydrofuran OV-96
Toluene OV-100
Total Aldehydes AL-50
Total Saturated Hydrocarbons OV-102
Trichloroethylene OV-105
Trifluoroacetic Acid OV-1066
Vinyl Acetate OV-109
Vinyl Chloride OV-100
VOC OV-00
Xylene OV-115
521 Organic Vapor Badges from Assay Technologies
521 Organic Vapor Badges are the perfect badge for testing for organic vapors. There are covers on each side of the monitor that can be removed to double the sampling rate. Even with only one cover removed the monitor samples approximately at 30 mL/min, depending on the chemical. Use this badge for monitoring of chemicals with a low PEL (10 ppm or less), STEL monitoring or for Indoor Air Quality situations. Note: There are a few chemicals that have PELs at 10 or below but are too volatile to be reliably collected by this fast sampling diffusive monitor.

List of Analytes Detected with the 521 Badge

Acetone Acetonitrile Acrylonitrile
Allyl chloride Amyl acetate Benzene
Benzyl chloride Bromofom 1,3-Butadiene
n-Butanol 2-Butoxyethanol 2-Butoxyethyl acetate
iso-Butyl acetate n-Butyl acetate t-Butyl acetate
Butyl acrylate iso=Butyl alcohol Butyl carbitol
tert-Butyl methyl ether Carbon tetrachloride Chlorobenzene
Chloroform 2-Chlorotoluene Cresol
Cumene Cyclohexane Cyclohexanol
Cyclohexanone Decane Diacetone alcohol
Diacetyl Cichloroifluoromethane 1,2-Dichlorobenzene
1,4-Dichlorobenzene 1,1-Dichloroethane 1,2-Dicholorethane
1,2-Dichloroethylene 1,2-Dimethyloxyethane 2,6-Dimethyl-4-Heptanone
n,n-Dimethylflormamide Dimethylsulfide Dimethyldisulfide
1,4-Dioxane Dipropylene Glycol Methyl Ether Epichlorohydrin
2-Ethoxyethanol Ethyl acetate Ethyl alcohol
Ethyl ether Ethyl lactate Ethylbenzene
Ethylene dibromide n-Heptane 2-Heptanone
2-Hexane 2-Hexanone Isobutyl acetate
Isooctane Isophorone Isopropyl acetate
Isopropyl alcohol Isopropyl ether d-Limonene
2-Methoxyethanol 2-Methoxyethyl acetate Methyl acrylate
Methyl alcohol Methyl cyclohexane Methyl ethyl ketone
Methyl methacrylate 2-Methyl pentane 3-Methyl pentane
1-Methyl-2-pyrrolidnone Methylcyclopentane Methylene chloride
alpha-Methylstyrene v,m&p-Naphtha Naphthalene
Nitromethane 1-Nitropropane 2-Nitropropane
Nonane n-Octane Pentane
2-Pentanone Perchloroethylene alpha-Pinene
beta-Pinene 4-Phenyl clyclohexene 1-Propanal
n-Propyl alcohol iso-Propyl alcohol n-Propyl bromide
Propylene dichloride Propylene glycol methyl ether Propylene glycol methyl ether acetate
Propylene oxide Pyridine Stoddard solvent
Styrene 1,1,2,2-Tetrachlorothane Tetrahydrofuran
Toluene 1,1,1-Trichloroethane 1,1,2-Trichloroethane
Trichloroethylene 1,1,2-Trichloro-1,2,2-trifluroethane 1,2,3-Trimethylbenzene
1,2,4-Trimethylbenzene 1,3,5-Trimethylbenzene Vinyl acetate
Vinyl bromide 4-Vinyl cyclohexane Vinyl methyl ether
n-Vinyl-2-pyrrolidinone Vinyl toluene Vinylidene chloride
Xylenes

Specifications

Sampling Medium Activated carbon, 300 mg, PTFE binder
Temperature Range 32 to 122°F
Relative Humidity Range 10 to 80%
Analytical Method Modified OSHA 7: Description in carbon disulfide with appropriate cosolvent analysis by GC/FID
Sampling Time 15 Minutes to 2 hours, 2 covers removed 2-12 hours, 1 cover removed
Sampling Rate Typically 30-90 LPM
Accuracy Meets or exceeds OSHA requirement for accuracy: Maximum total error ≤25% at PEL
Storage Store a controlled room temperature. Do not use after expiration date.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
Charcoal Badge, pk/5, for one chemical
X521-1
Charcoal Badge, pk/5, for 4 chemicals X521-4
Charcoal Badge, pk/5 Organic Solvent Panel X521-25

Downloads

Technical literature for 521 Organic Vapor Charcoal Badges Instructions for use  TraceAir Field Validation 1993 Benzene, Toluene, Ethyl Benzene, Xylenes
ORSA Passive Organic Vapor Samping Badges

The ORSA is a diffusion sampler for monitoring organic compounds. The contaminant molecules from the ambient air are adsorbed by the activated charcoal which is later analyzer using laboratory methods.

ORSA is used to determine average concentrations from 1 to 8 hours and for the investigation of lower concentration ranges over prolonged periods of time (e.g. 168 hours for the sampling of perchloroethylene). The ORSA includes 5 samplers, holders and shipping vials. The ORSA 25 includes 25 samplers, 10 holders and 25 shipping vials.

Ordering Information

Badge Catalog No.
ORSA, pk/5
6728891

Downloads

ORSA Organic Vapor Monitoring Badge Literature

Morphix Technologies TraceX Explosives Kit
The TraceX Explosives Detection Kit is designed to help identify bombers, bomb-makers and their bomb-making facilities. It detects the most common explosive materials and their precursors at trace levels in a single test. Explosives remain the weapon of choice for terrorists around the world. Improvised Explosive Devices (IEDs) are a threat from international terrorist organizations and local, home-grown terrorists as well. Sadly, Home Made Explosives (HMEs) and IEDs have become a fact of modern life. Military, law enforcement and intelligence personnel have a dual-role: uncovering the bomb networks and systems before the bombers do harm, and investigating an incident after it occurs. In many cases, detecting just a trace of explosive material can make all the difference. A traditional portable electronic explosive detection device requires a great deal of specialized training, a large budget and regular maintenance. While there is a need for these electronic portable trace explosive detectors and larger trace explosive detection systems, there is a growing demand for colorimetric explosive detection kits for use in the field. A number of these kits have existed for some time; however they often require the user to mix chemicals, perform serial analyses, conduct multiple swabs or tests, and then use a chart to interpret the results. Said plainly, existing colorimetric explosive detection kits are difficult to use, especially in stressful situations. Even worse, many colorimetric explosive detection kits can expose the user to dangerous chemicals, and expose the kit to contamination from the environment or the user, leading to unreliable results. Some colorimetric explosive detection kits can only be used for bulk detection; however explosive trace detection is critical in many real-world applications. The TraceX explosives detection kit is much more convenient. Simple to use and low cost, it is an explosive detector that can be used by every warfighter or law enforcement officer. With a single swab, the TraceX explosives kit detects all the major families of explosive materials and their precursors. Thanks to the TraceX’s simple color-change alert system, a single color indicates the presence of a particular family of explosive material. No longer does the user have to conduct serial tests, and then try to interpret the results. The TraceX explosives detection kit was developed by Morphix Technologies under contract from the US Department of Defense, so you know it’s tough. It is small enough to fit in a cargo pocket, lightweight and rugged. Each detection kit comes in its own disposable protective plastic case, so it will be ready to use when needed. No more broken ampules from rough handling, as can happen with other explosive detectors. And, the innovative collection system protects the sample from user contamination, so you can have confidence in the result. As the name implies, TraceX is sensitive enough to be used for explosive trace detection.  It detects bulk explosives too.

Chemicals Detected

  • Nitroaromatics including TNT, DNT, Tetryl
  • Nitramines & Nitrate Esters including RDX, HMX, PETN, EGDN & NG
  • Inorganics Nitrates such as urea nitrate, ammonium nitrate & black powder
  • Chlorates & Bromates – potassium chlorate, potassium bromate
  • Peroxides – TATP & HMTD
  • Acids – nitric acid, sulfuric acid, citric acid
  • Bases – potassium hydroxide & sodium hydroxide

Competitive Comparisons

TraceX Wipes Pens
# of Explosive Families Detected in 1 Test Cycle 9 1-41 1-31
Trace Detection Yes Yes Yes & No1
Bulk Detection Yes Yes Yes
Ease of Use Single swab & crush Multiple swab & crush cycles, until a positive indication occurs Multiple swab & crush cycles, until a positive indication occurs
Interpretation of Results Results clearly indicated User interprets results based on color formed after serial analyses User interprets patterns from multiple pens
User Safety All chemicals contained inside plastic case Possible user exposure to chemicals Possible user exposure to chemicals
Potential for Sample Contamination Low3 High3 Medium3
Ruggedness Each kit encased in protective plastic case Fragile ampules are minimally protected Fragile ampules have limited protection provided by pen casing
Heat Source Required No Yes and No1 No
Time for Results ≤ 3 minutes total 2-12 minutes2 2-12 minutes2
1 Depends on specific product 2 Each test can takes about 2 minutes; total time depends on number of tests run in series 3 For TraceX Explosive Kit, sampling site is protected by cover and user swabs with handle. For Wipes, user touches sampling site when swabbing, in some kits, reuse of dropper may introduce contamination. For Pens, user must avoid touching of pen.

Specifications

Operating Temperature 2°C to 50°C
Operating Humidity 10% to 95% RH
Sensitivity Trace level, can also detect bulk levels
Time for Color Change Less than 3 minutes
Kit Size 5 ¼” x 3 ¾” x ¾”
Shelf Life 12 months*
*Store at room temperature. Short term excursions up to 50°C are acceptable

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
TraceX Explosives Detector Kit, pk/5 510100-05
TraceX Explosives Training Kit, pk/5 510110-05

Downloads

Morphix TraceX Explosive Detector Kit Literature TraceX Operating Instructions TraceX User Guide
Chameleon WMD & ClanLab Badges from Morphix-NEW Cassettes Available

The Chameleon is the most innovative hazardous chemical detection device on the market today! Morphix Technologies has revolutionized simple color change technology and made it rugged to meet the needs of First Responders and military personnel. The Chameleon easily attaches to the forearm for hands free detection of gases and vapors in the air – no need for a liquid sample. The design also eliminates interferences from smoke or particulates. The Chameleon armband is field configurable, allowing you to decide which chemical threats you need to detect. The Chameleon armband is designed for easy on/off to fit any forearm; even over turn out gear. It can be used for one cassette or as many as ten.

The Chameleon was developed under a grant from the United States Marine Corps to provide low cost, disposable chemical detection. The Chameleon armband and cassettes have been designed to meet the stringent requirements of the Marine Corps, including use under harsh environmental conditions and immersion in salt and fresh water.

Chemical detection has never been easier. If half of the viewing window changes color – the chemical is present; it really is that simple. No power, no calibration.

The Chameleon’s rugged design allows for use in extreme heat and extreme cold conditions and in wet or dry environments. Even after immersion in water, just shake off the residual water and detect the invisible threats.

Sensors Available

  • Low pH (acid)
  • High pH (base)
  • Chlorine/Fluorine
  • Hydrogen Cyanide
  • Nitrogen Dioxide
  • Ammonia
  • Diborane
  • Phosgene
  • Hydrogen Sulfide
  • Hydrogen Fluoride
  • Hydrazine
  • Iodine
  • Phosphine
  • Sulfur Dioxide

Specifications

Cassette Shelf Life 24 months at room temperature*
Cassette Service Life 24 hours
Temperature -22°F to 122°F
Humidity Range 20 to 100% RH
Immersion 1 hour
Sensitivity at PEL Concentration Color change in < 30 minutes
Sensitivity at One Half IDLH Concentration Color change in <5 minutes

*Phosphine cassette has a 6 month shelf life if stored at room temperature

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
HazMat Detection Kit includes 2 armbands, 10 cassette holder 10 pouches containing one cassette of each of the following: chlorine/fluorine, hydrogen fluoride, diborane, high pH (base), hydrazine, hydrogen sulfide, iodine, low pH (acid), phosgene, phopshine and sulfur dioxide in a carrying case
085110
HazMat Detection Kit includes 2 extra long armbands, 10 cassette holder 10 pouches containing one cassette of each of the following: chlorine/fluorine, hydrogen fluoride, diborane, high pH (base), hydrazine, hydrogen sulfide, iodine, low pH (acid), phosgene, phosphine and sulfur dioxide in a carrying case
085110XL
HazMat Refill Kit includes 10 cassettes each of acid, base, chlorine/fluorine, hydrogen fluoride, diborane, hydrazine, hydrogen sulfide, iodine, phosgene, phosphine, sulfur dioxide
085111
Methamphetamine Lab Detection Kit includes 2 Chameleon armbands, and 10 cassettes each of ammonia, hydrogen sulfide, iodine, low pH (acid) and phosphine in a carrying case
085120
Methamphetamine Lab Detection Kit includes 2 extra long Chameleon armbands, and 10 cassettes each of ammonia, hydrogen sulfide, iodine, low pH (acid) and phosphine & carrying case
085120XL
Clan-Meth Lab Detection Cassette Refill Kit includes 10 cassettes each of low pH (acid), ammonia, iodine, phosphine and hydrogen sulfide
085121
Chemical Suicide Detection Cassette Refill Kit includes 10 cassettes each of high pH (base), low pH (acid), sulfur dioxide, phosphine and hydrogen sulfide
085141
Chemical Suicide Detection Kit includes 2 armbands, and 10 cassettes of high pH (acid), hydrogen sulfide, low pH (base), phosgene, sulfur dioxide & carrying case 085140
Chemical Suicide Detection Kit includes 2 extra long armbands, and 10 cassettes of high pH (acid), hydrogen sulfide, low pH (base), phosgene, sulfur dioxide & carrying case 085140XL
Arson Investigation Kit includes 2 Chameleon armbands and 10 cassettes each of ammonia, low pH, hydrogen cyanide, hydrogen fluoride, hydrogen sulfide, nitrogen dioxide, phosgene and sulfur dioxide and carrying case 085190
Arson Investigation Kit includes 2 Chameleon XL armbands and 10 cassettes each of ammonia, low pH, hydrogen cyanide, hydrogen fluoride, hydrogen sulfide, nitrogen dioxide, phosgene and sulfur dioxide and carrying case 085190XL
Arson Investigation Cassette Refill Kit includes 10 cassettes each of ammonia, low pH, hydrogen cyanide, hydrogen fluoride, hydrogen sulfide, nitrogen dioxide, phosgene and sulfur dioxide 085191
Training Kit includes 1 armband with 10 inactive cassettes, 50 training cassettes and 50 ampules
085130
Training Kit replacement includes 50 training cassettes and 50 ampules
085131
Chameleon Armband, 10 cassette holder, pk/5
085000
Chameleon Armband, 10 cassette holder, pk/5, extra long
085000XL
Acid Cassette, pk/50
084005-50
Ammonia Cassette, pk/50
084015-50
Base Cassette, pk/50
084020-50
Hydrogen Sulfide Cassette, pk/50
084030-50
Iodine Cassette, pk/50
084052-50
Chlorine/Fluorine Cassette, pk/50
084035-50
Phosgene Cassette, pk/50
084060-50
Phosphine Cassette, pk/50
084061-50
Sulfur Dioxide Cassette, pk/50
084065-10
Diborane Cassette, pk/50
084040-50
Hydrazine Cassette, pk/50
084045-50
Hydrogen Cyanide 084048-50
Hydrogen Fluoride 084049-50
Nitrogen Dioxide 084054-50

Downloads

Chameleon Technical literature

Chameleon Colorimetric Badge literature

Meth Lab literature

Acid Cassette instructions

Base Cassette instructions

Hydrogen Sulfide Cassette instructions

Chlorine/Fluorine Cassette instructions

Phosgene Cassette instructions

Ammonia Cassette instructions

Diborane Cassette instructions

Hydrazine Cassette instructions

Iodine Cassette instructions

Phosphine Cassette instructions

Sulfur Dioxide Cassette instructions

Hydrogen Cyanide instructions

Hydrogen Fluoride instructions

Nitrogen Dioxide instructions

ChromAir Direct Read Colorimetric Badges from Morphix Technologies

The ChromAir badge is a colorimetric direct read monitor and a color comparison chart. It relies on the principle of diffusion, therefore it requires no pump to operate. Unlike traditional diffusion tubes, the patented design of the ChromAir badge provides a short and constant diffusion path irrespective of the sampling time or concentration of the contaminant. This unique feature provides accurate results immediately and throughout the sampling period.

The ChromAir monitor provides the user with six exposure levels*. Most ChromAir badges indicate from 1/10 to 2 times the time weighted average for an eight hour work period. The scale** printed on the badges and color comparators is based on exposure dose (parts per million time hour (ppm x hr). To determine the average concentration, the user locates the highest cell with a color changes and divides the corresponding dose level (ppm x hr) by the sampling time in hours (hrs). If the sampling time is 2 hours and badge reads 40 ppm x hr, the average concentration is 20 ppm.

For higher resolution and wider range, the ChromAir badge may be used in conjunction with the ChromAir color comparator. The color scales on the color comparators identically match the colors formed on the ChromAir badges.

Features

  • Immediate on-site results
  • Easy to read color change
  • Highly sensitive and selective
  • Exposure data read directly from badge
  • Immediate response for short term exposure measurements
  • Measures TWA exposures
  • No laboratory analysis needed
  • Lightweight and cost effective for personnel and area monitoring

*The ChromAir mercury and glutaraldehyde badges have five levels.

**The ChromAir mercury badge scale is mg/m3 x hr. The glutaraldehyde STEL badge is in ppm.

Ordering Information

For more information on each individual badge, click on the catalog number for a pdf. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Analyte
Range
(ppm x hr)
Min. Detectable Concentration
in 8 hours***
Interferences
Catalog No.
Acetone
20-24,000
2.5 ppm
NH3, MEK, MIBK, MPK
380020-10
Ammonia
4-300
0.5 ppm
RNH2
380003-10
Carbon Monoxide
10-525
1.25 ppm
Alkenes, H2, H2S
380008-10
Chlorine
0.4-13
0.05 ppm
Br2, I2
380004-10
Formaldehyde
0.3-12
0.04 ppm
None Known
380007-10
Glutaraldehyde
STEL (15 min)
0.04-0.95 ppm
None Known
380017-10
Mercury
0.125-1.6 mg/m3 x hr
0.02 mg/m3
Strong Oxidizers
380018-10
Methyl Ethyl Ketone
18-21,600
2.25 ppm
NH3, acetone, MIBK, MPK
380020-10
Methyl Isobutyl Ketone
16-19,200
2.0 ppm
NH3, MEK, Acetone, MPK
380020-10
Ozone
0.08-1.6
0.01 ppm
H2O2, NO2**
380010-10

*3 ppm H2S causes color development in cell 1, 10 ppm H2S causes color development in cell 2.

**Ozone monitor is ten times more sensitive to ozone than to nitrogen dioxide.

***Coefficient must be applied to scale printed on badge.

Color Comparators

Description
Catalog No.
Carbon Monoxide Color Comparator
348006
Formaldehyde Color Comparator
384001

Downloads

Chromair Badge Literature

Response Time and Interchangeability Effects on the Tube-Like and the Badge-Like Passive Direct-Read Monitors

Direct-Read Monitoring System for Carbon Monoxide

Personal Monitoring in the Workplace

SafeAir Direct Read Colorimetric Badges from Morphix Technologies

The SafeAir Badge provides an immediate visual indication when a specific chemical hazard is present. The sensor in the SafeAir badge is constructed from a coated indicator layer rather than impregnated paper. This provides a homogeneous and stable color formation. The indicator layers are highly sensitive and selective to the targeted chemicals. A color change, in the form of an “exclamation point”, warns the presence of the targeted hazard. SafeAir is a low cost chemical detector badge allowing companies to perform daily exposure screening. The badge requires minimal training. There is no calibration, extra equipment or laboratory analysis required.

Features

  • Provides immediate visual indication when specific chemical is present. Homogeneous and stable color formation due to coated indicator layer
  • Highly sensitive and selective
  • Ideal for leak detection and daily exposure screening
  • No laboratory analysis required

The dual purpose badge is available for chlorine and chlorine dioxide which often coexist in the same environment. This badge selectively indicates the presence of chlorine on the front side of the badge and chlorine dioxide on the back side. Indications may appear on both sides if both chemicals are present.

The mercury and 1,1-dimethyl hydrazine badges provide the user with two independent threshold levels. The front of the badge indicates one threshold level while the back provides a second level. This unique feature allows the badge to be used as an inexpensive range finder.

For higher resolution and wider range, the SafeAir badge may be used in conjunction with the SafeAir Color Comparator. The color scales on the color comparators identically match the colors formed on the SafeAir badges.

Specifications

For more information on each individual badge, click on the catalog number for a pdf.

Analyte
Threshold Level
Min Detectable Conc in 8 Hrs (ppm)
MRST* (Hrs)
SRST** (Mins)
Cross Sensitivity
Ammonia
4 ppm x hr
0.5 ppm
48
15
Aliphatic amines
Carbon Monoxide
7 ppm x hr
0.9 ppm
10
15
Alkenes, H2, H2S
Chlorine
0.18 ppm x hr
0.023 ppm
48
15
Br2, HCl, I2
Chlorine/
Chlorine dioxide
Cl2: 0.18 ppm x hr
Cl2: 0.025 ppm
10
15
Cl2: Br2, HCl, I2
ClO2: 0.2 ppm x hr
ClO2: 0.025 ppm
ClO2: NO2,
high conc O3
Formaldehyde
0.2 ppm x hr
0.05 ppm
16
15
Acrolein
Hydrazine
8 ppb x hr
1 ppb
48
5
MMH, Aromatic Amines
Hydrogen Chloride
2 ppm
15 min
15
None Known
Hydrogen Sulfide
2 ppm x hr
0.25 ppm
48
15
None Known
Mercury/Dual Level
Front: 0.25 mg/m3 x hr
Front: 0.031 mg/m3
48
15
Strong oxidizers
Back: 0.08 mg/m3 x hr
Back: 0.01 mg/m3
MDI
3.5 ppb x hr
0.4 ppb
24
15
Aromatic Diisocyantes,
Hydrazines
Ozone
0.05 ppm x hr
0.006 ppm
48
15
H2O2 above 1 ppm NO2
Phosgene
8.3 ppb x hr
0.001 ppm
72
1
Caronyl bromide, Chloroformates
Phosgene Dura 20 ppb x hr 120 1 Caronyl bromide,
Chloroformates
Phosgene Medi 166.7 ppb x hr 120 1 Caronyl bromide,
Chloroformates
Sulfur Dioxide
0.2 ppm x hr
0.025 ppm
48
15
None Known
TDI
5.0 ppb x hr
0.6 ppb
24
15
Aromatic Diisocyanate
Hydrazine

*Maximum recommended sampling time

**Shortest recommended sampling time

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Ammonia SafeAir Badges, pk/50 382010-50
Carbon Monoxide SafeAir Badges, pk/50
Chlorine SafeAir Badges, pk/50
Chlorine/Chlorine Dioxide SafeAir Badges, pk/50
Formaldehyde SafeAir Badges, pk/50
Hydrazine SafeAir Badges, pk/50
Hydrogen Chloride SafeAir Badges, pk/50
Hydrogen Sulfide SafeAir Badges, pk/50
Mercury/Dual Level SafeAir Badges, pk/50
Aromatic Isocyanates SafeAir Badges, pk/50
Ozone SafeAir Badges, pk/50
Phosgene SafeAir Badges, pk/50
Phosgene SafeAir Dura Badge, pk/50 382065-50
Phosgene SafeAir Medi Badge, pk/50 382060-50
Sulfur Dioxide SafeAir Badges, pk/50

Color Comparators

Description
Catalog No.
Chlorine Color Comparator
383010
Hydrazine Color Comparator
383001
Hydrogen Chloride Color Comparator
383008
Phosgene Color Comparator
383016
Phosgene Dura Color Comparator 383022
Phosgene Medi Color Comparator 383020
TDI Color Comparator
383005

Downloads

Safeair Colorimetric Badge Literature

Response Time and Interchangeability Effects on the Tube-Like and the Badge-Like Passive Direct-Read Monitors

Direct-Read Monitoring System for Carbon Monoxide

Personal Monitoring in the Workplace

Non-Charcoal Organic Vapor Monitoring Badges
Features US Patented badges are analyzed using OSHA and NIOSH validated methods Analyzed by an AIHA accredited lab The lab is rated proficient in the NIOSH Proficiency Analysis Testing Program (PAT) for Analytes Tested. All compounds listed for full analysis badge (OV-OOFull) will be tested for and reported if found The same badge can be used for either TWA or STEL sampling All inclusive price for badge, analysis and report Report by fax, if requested, always by phone for high results Summary reports available Now ISO 9001:2015 certified Compounds Detachable with the OV-OO Full Analysis Badge Acetone 1,2-Dichloroethane Methyl Methacrylate Acetonitrile 1,2-Dichloropropane Methyl-t butyl Ether Acrylonitrile Dimethyl Formamide Methyl Styrene Allyl Chloride Dimethyl Sulfoxide Methylene Chloride Benzene Dioxane Nonane 1-Chloro-4-Benzene Ethyl Acetate Pentane Benzyl Chloride Ethyl Alcohol Pentane Acetate 1,3-Butadiene Ethyl Benzene n-Pentanone 2-Butanone (MEK) Ethyl Ether Perchloroethylene Butyl Acetate Ethyl Methacrylate n-Propyl Acetate Butyl Cellosolve 4-Ethyltoluene Propyl Benzene 1-Butyl Alcohol Heptane n-Propyl Bromide 2-Butyl Alcohol 2-Heptanone Propylene Oxide Carbon Tetrachloride Hexane Pyridine Cellosolve 1-Hexanol Sytrene Chlorobenzene Hexone (MIBK) Tetrahydrofuran Chloroform Isopropyl Alcohol Toluene Cyclohexane Isooctane 1,1,1-Trichloroethane Cyclohexene d-Limonene Trichloroethylene Cyclohexanol Methyl Acetate 1,2,4-Trimethylbenzene Cyclohexanone Methyl Acrylate Vinyl Acetate Dibromochloromethane Methyl Chloroform Vinyl Chloride 1,4-Dichlorobenzene 5-Methyl-2-Hexanone Xylene Specifications Accuracy Better than +25% at the 95% confidence interval Limits of Detection Lower: Generally better than 1/10 of the PEL Upper: At least 2 times PEL Shelf Life 1 year at room temperature Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Badge Catalog No. Organic Vapor Badge, Full Analysis OVF-00 a-Methyl Styrene OV-771 1,1,2-Trichloroethane OV-104 1,2,4-Trimethyl Benzene OV-107 1,3-Butadiene OV-12 2-Butanol OV-152 2-Butoxyethanol OV-16 2-Butoxyethytl Acetate OV-412 2-Mercaptoehtanol OV-579 2-Methoxyethylacetate OV-58 2-Phenoxyethanol OV-413 2-Propanol OV-86 Acetaldehydes OV-004 Acetic Acid OV-005 Acetone V OV-01 Acetonitrile OV-5 Acetophenone OV-052 Acrolein OV-055 Acrylamide OV-557 Acrylonitrile OV-06 Allyl Alcohol OV-07 Ammonia K-10 Amyl acetate OV-076 Aniline OV-077 BTEX OV-09 Benzene OV-08 Benzoic Acid OV-085 Benzyl Chloride V OV-10 Beta Mercaptoethanol OV-585 Biphenyl OV-11 BTEX + Saturated Hydrocarbons OV-095 Butyl Acetate OV-14 Butyl Alcohol OV-15 Butyl Cellosolve Acetate OV-15 Butylene Oxide OV-165 Carbon Disulfide OV-195 Carbon Tetrachloride OV-20 Cellosolve OV-22 Chlorobenzene OV-25 Chloroform OV-30 Collodion OV-31 Cumene OV-311 Cylcohexane OV-313 Cyclohexanol OV-314 Desflurane H-10-D Dibromomethane OV-778 Dichloroethane OV-318 Dihloromethane OV-317 Diesel Fuel OV-33 Diethylaminoethanol OV-309 Diethylene Glycol OV-320 Dimethyl Formamide OV-326 Dimethyl Fumarate OV-330 Dimethyl Sulfoxide OV-325 Dimethylacetamide OV-328 Dioxane OV-319 Dipropylene Glycol Methyl Ether OV-333 Enflurane H-10-E Epichlorohydrin OV-335 Ethyl Acetate OV-34 Ethyl Alcohol OV-35 Ethyl Benzene OV-37 Ethyl Ether OV-40 Ethyl Methacryalate OV-406 Ethylene Glycol OV-41 Ethylene Oxide E-50 Formaldehyde F-50 Formaldehyde & Glutaraldehyde FG-50 Formaldehyde & o-Phthalaldehyde FOP-50 Formaldehyde IAQ F-50I Formaldehyde, Glutaraldehydel & o-Phthalaldehyde FGOP-50 Formamide OV-415 Full Scan Organic IAQ OVFI-00 Gasoline OV-45 Glutaraldehyde G-10 Glutaraldehyde & o-Phthalaldehyde GOP-10 Halogenated Anesthetic H-10-3 Halothane H-10-H Heptane OV-50 Hexane OV-55 Hexylene Glycol OV-555 Hydrogen Peroxide HP-10 Hydrogen Sulfide HS-10 Hydroquinone OV-56 Isobutyl Alcohol OV-561 Isoflurane H-10-I ISophorone OV-575 Isopropyl Alcohol OV-57 Jet Fuel OV-576 Kerosene OV-578 Limonene OV-577 m-Cresol OV-312 Mercury HG-10 Methyl (n-Amyl) Ketone OV-615 Methyl Alcohol OV-60 Methyl Bromide OV-595 Methyl Chloride OV-63 Methyl Chloroform OV-65 Methyl Ethyl Ketone OV-71 Methyl Ethyl Ketoxime OV-72 Methyl Iodide OV-755 Methyl Isobutyl Ketone OV-76 Methyl Methacrylate M-10 Methyl t-Butyl Ether OV-62 Methyelene Chloride OV-70 Metofane H-10-M Mineral Spirits OV-77 Morpholine OV-772 n-Butyl Glycidal Ether OV-157 n-Butyl Mercapatan OV-166 n-Propyl Bromide OV-88 Naphtha OV-776 Naphthalene OV-775 Nitrilotriacetonitrile OV-779 Nitrobenzene OV-777 Nitrogen Dioxide NO-10 Nitromethane OV-780 Nitrous Oxide N-10 o-Phthalaldehyde OP-10 p-Dichlorobenzene OV-361 Pentane OV-78 Perchloroethylene OV-80 Petroleum Distillates OV-81 Phenol OV-85 Propargyl Alcohol OV-87 Propionic Acid OV-875 Propoxur OV-876 Propylene Glycol OV-885 Pyridine OV-91 Sevoflurane H-10-S Stoddard Solvent OV-93 Styrene OV-95 Sulfur Dioxide SD-10 Tetrahydrofuran OV-96 Toluene OV-100 Total Aldehydes AL-50 Total Saturated Hydrocarbons OV-102 Trichloroethylene OV-105 Trifluoroacetic Acid OV-1066 Vinyl Acetate OV-109 Vinyl Chloride OV-100 VOC OV-00 Xylene OV-115
Manufacturer: Advanced Chemical Sensors Inc
Brand: Organic Vapor Badges
Model: OVM
Short Description:
521 Organic Vapor Badges from Assay Technologies
521 Organic Vapor Badges are the perfect badge for testing for organic vapors. There are covers on each side of the monitor that can be removed to double the sampling rate. Even with only one cover removed the monitor samples approximately at 30 mL/min, depending on the chemical. Use this badge for monitoring of chemicals with a low PEL (10 ppm or less), STEL monitoring or for Indoor Air Quality situations. Note: There are a few chemicals that have PELs at 10 or below but are too volatile to be reliably collected by this fast sampling diffusive monitor. List of Analytes Detected with the 521 Badge Acetone Acetonitrile Acrylonitrile Allyl chloride Amyl acetate Benzene Benzyl chloride Bromofom 1,3-Butadiene n-Butanol 2-Butoxyethanol 2-Butoxyethyl acetate iso-Butyl acetate n-Butyl acetate t-Butyl acetate Butyl acrylate iso=Butyl alcohol Butyl carbitol tert-Butyl methyl ether Carbon tetrachloride Chlorobenzene Chloroform 2-Chlorotoluene Cresol Cumene Cyclohexane Cyclohexanol Cyclohexanone Decane Diacetone alcohol Diacetyl Cichloroifluoromethane 1,2-Dichlorobenzene 1,4-Dichlorobenzene 1,1-Dichloroethane 1,2-Dicholorethane 1,2-Dichloroethylene 1,2-Dimethyloxyethane 2,6-Dimethyl-4-Heptanone n,n-Dimethylflormamide Dimethylsulfide Dimethyldisulfide 1,4-Dioxane Dipropylene Glycol Methyl Ether Epichlorohydrin 2-Ethoxyethanol Ethyl acetate Ethyl alcohol Ethyl ether Ethyl lactate Ethylbenzene Ethylene dibromide n-Heptane 2-Heptanone 2-Hexane 2-Hexanone Isobutyl acetate Isooctane Isophorone Isopropyl acetate Isopropyl alcohol Isopropyl ether d-Limonene 2-Methoxyethanol 2-Methoxyethyl acetate Methyl acrylate Methyl alcohol Methyl cyclohexane Methyl ethyl ketone Methyl methacrylate 2-Methyl pentane 3-Methyl pentane 1-Methyl-2-pyrrolidnone Methylcyclopentane Methylene chloride alpha-Methylstyrene v,m&p-Naphtha Naphthalene Nitromethane 1-Nitropropane 2-Nitropropane Nonane n-Octane Pentane 2-Pentanone Perchloroethylene alpha-Pinene beta-Pinene 4-Phenyl clyclohexene 1-Propanal n-Propyl alcohol iso-Propyl alcohol n-Propyl bromide Propylene dichloride Propylene glycol methyl ether Propylene glycol methyl ether acetate Propylene oxide Pyridine Stoddard solvent Styrene 1,1,2,2-Tetrachlorothane Tetrahydrofuran Toluene 1,1,1-Trichloroethane 1,1,2-Trichloroethane Trichloroethylene 1,1,2-Trichloro-1,2,2-trifluroethane 1,2,3-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3,5-Trimethylbenzene Vinyl acetate Vinyl bromide 4-Vinyl cyclohexane Vinyl methyl ether n-Vinyl-2-pyrrolidinone Vinyl toluene Vinylidene chloride Xylenes Specifications Sampling Medium Activated carbon, 300 mg, PTFE binder Temperature Range 32 to 122°F Relative Humidity Range 10 to 80% Analytical Method Modified OSHA 7: Description in carbon disulfide with appropriate cosolvent analysis by GC/FID Sampling Time 15 Minutes to 2 hours, 2 covers removed 2-12 hours, 1 cover removed Sampling Rate Typically 30-90 LPM Accuracy Meets or exceeds OSHA requirement for accuracy: Maximum total error ≤25% at PEL Storage Store a controlled room temperature. Do not use after expiration date. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com Description Catalog No. Charcoal Badge, pk/5, for one chemical X521-1 Charcoal Badge, pk/5, for 4 chemicals X521-4 Charcoal Badge, pk/5 Organic Solvent Panel X521-25 Downloads Technical literature for 521 Organic Vapor Charcoal Badges Instructions for use  TraceAir Field Validation 1993 Benzene, Toluene, Ethyl Benzene, Xylenes
Manufacturer:
Brand:
Model:
Short Description:
ORSA Passive Organic Vapor Samping Badges
The ORSA is a diffusion sampler for monitoring organic compounds. The contaminant molecules from the ambient air are adsorbed by the activated charcoal which is later analyzer using laboratory methods. ORSA is used to determine average concentrations from 1 to 8 hours and for the investigation of lower concentration ranges over prolonged periods of time (e.g. 168 hours for the sampling of perchloroethylene). The ORSA includes 5 samplers, holders and shipping vials. The ORSA 25 includes 25 samplers, 10 holders and 25 shipping vials. Ordering Information Badge Catalog No. ORSA, pk/5 6728891 Downloads ORSA Organic Vapor Monitoring Badge Literature
Manufacturer: Draeger Safety Inc
Brand: Organic Vapor Badges
Model: ORSA
Short Description:

The ORSA is a diffusion sampler for monitoring organic compounds. The contaminant molecules from the ambient air are adsorbed by the activated charcoal which is later analyzer using laboratory methods.

Morphix Technologies TraceX Explosives Kit
The TraceX Explosives Detection Kit is designed to help identify bombers, bomb-makers and their bomb-making facilities. It detects the most common explosive materials and their precursors at trace levels in a single test. Explosives remain the weapon of choice for terrorists around the world. Improvised Explosive Devices (IEDs) are a threat from international terrorist organizations and local, home-grown terrorists as well. Sadly, Home Made Explosives (HMEs) and IEDs have become a fact of modern life. Military, law enforcement and intelligence personnel have a dual-role: uncovering the bomb networks and systems before the bombers do harm, and investigating an incident after it occurs. In many cases, detecting just a trace of explosive material can make all the difference. A traditional portable electronic explosive detection device requires a great deal of specialized training, a large budget and regular maintenance. While there is a need for these electronic portable trace explosive detectors and larger trace explosive detection systems, there is a growing demand for colorimetric explosive detection kits for use in the field. A number of these kits have existed for some time; however they often require the user to mix chemicals, perform serial analyses, conduct multiple swabs or tests, and then use a chart to interpret the results. Said plainly, existing colorimetric explosive detection kits are difficult to use, especially in stressful situations. Even worse, many colorimetric explosive detection kits can expose the user to dangerous chemicals, and expose the kit to contamination from the environment or the user, leading to unreliable results. Some colorimetric explosive detection kits can only be used for bulk detection; however explosive trace detection is critical in many real-world applications. The TraceX explosives detection kit is much more convenient. Simple to use and low cost, it is an explosive detector that can be used by every warfighter or law enforcement officer. With a single swab, the TraceX explosives kit detects all the major families of explosive materials and their precursors. Thanks to the TraceX’s simple color-change alert system, a single color indicates the presence of a particular family of explosive material. No longer does the user have to conduct serial tests, and then try to interpret the results. The TraceX explosives detection kit was developed by Morphix Technologies under contract from the US Department of Defense, so you know it’s tough. It is small enough to fit in a cargo pocket, lightweight and rugged. Each detection kit comes in its own disposable protective plastic case, so it will be ready to use when needed. No more broken ampules from rough handling, as can happen with other explosive detectors. And, the innovative collection system protects the sample from user contamination, so you can have confidence in the result. As the name implies, TraceX is sensitive enough to be used for explosive trace detection.  It detects bulk explosives too. Chemicals Detected Nitroaromatics including TNT, DNT, Tetryl Nitramines & Nitrate Esters including RDX, HMX, PETN, EGDN & NG Inorganics Nitrates such as urea nitrate, ammonium nitrate & black powder Chlorates & Bromates – potassium chlorate, potassium bromate Peroxides – TATP & HMTD Acids – nitric acid, sulfuric acid, citric acid Bases – potassium hydroxide & sodium hydroxide Competitive Comparisons TraceX Wipes Pens # of Explosive Families Detected in 1 Test Cycle 9 1-41 1-31 Trace Detection Yes Yes Yes & No1 Bulk Detection Yes Yes Yes Ease of Use Single swab & crush Multiple swab & crush cycles, until a positive indication occurs Multiple swab & crush cycles, until a positive indication occurs Interpretation of Results Results clearly indicated User interprets results based on color formed after serial analyses User interprets patterns from multiple pens User Safety All chemicals contained inside plastic case Possible user exposure to chemicals Possible user exposure to chemicals Potential for Sample Contamination Low3 High3 Medium3 Ruggedness Each kit encased in protective plastic case Fragile ampules are minimally protected Fragile ampules have limited protection provided by pen casing Heat Source Required No Yes and No1 No Time for Results ≤ 3 minutes total 2-12 minutes2 2-12 minutes2 1 Depends on specific product 2 Each test can takes about 2 minutes; total time depends on number of tests run in series 3 For TraceX Explosive Kit, sampling site is protected by cover and user swabs with handle. For Wipes, user touches sampling site when swabbing, in some kits, reuse of dropper may introduce contamination. For Pens, user must avoid touching of pen. Specifications Operating Temperature 2°C to 50°C Operating Humidity 10% to 95% RH Sensitivity Trace level, can also detect bulk levels Time for Color Change Less than 3 minutes Kit Size 5 ¼” x 3 ¾” x ¾” Shelf Life 12 months* *Store at room temperature. Short term excursions up to 50°C are acceptable Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. TraceX Explosives Detector Kit, pk/5 510100-05 TraceX Explosives Training Kit, pk/5 510110-05 Downloads Morphix TraceX Explosive Detector Kit Literature TraceX Operating Instructions TraceX User Guide
Manufacturer:
Brand:
Model:
Short Description:
Chameleon WMD & ClanLab Badges from Morphix-NEW Cassettes Available
The Chameleon is the most innovative hazardous chemical detection device on the market today! Morphix Technologies has revolutionized simple color change technology and made it rugged to meet the needs of First Responders and military personnel. The Chameleon easily attaches to the forearm for hands free detection of gases and vapors in the air – no need for a liquid sample. The design also eliminates interferences from smoke or particulates. The Chameleon armband is field configurable, allowing you to decide which chemical threats you need to detect. The Chameleon armband is designed for easy on/off to fit any forearm; even over turn out gear. It can be used for one cassette or as many as ten. The Chameleon was developed under a grant from the United States Marine Corps to provide low cost, disposable chemical detection. The Chameleon armband and cassettes have been designed to meet the stringent requirements of the Marine Corps, including use under harsh environmental conditions and immersion in salt and fresh water. Chemical detection has never been easier. If half of the viewing window changes color – the chemical is present; it really is that simple. No power, no calibration. The Chameleon’s rugged design allows for use in extreme heat and extreme cold conditions and in wet or dry environments. Even after immersion in water, just shake off the residual water and detect the invisible threats. Sensors Available Low pH (acid) High pH (base) Chlorine/Fluorine Hydrogen Cyanide Nitrogen Dioxide Ammonia Diborane Phosgene Hydrogen Sulfide Hydrogen Fluoride Hydrazine Iodine Phosphine Sulfur Dioxide Specifications Cassette Shelf Life 24 months at room temperature* Cassette Service Life 24 hours Temperature -22°F to 122°F Humidity Range 20 to 100% RH Immersion 1 hour Sensitivity at PEL Concentration Color change in < 30 minutes Sensitivity at One Half IDLH Concentration Color change in <5 minutes *Phosphine cassette has a 6 month shelf life if stored at room temperature Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. HazMat Detection Kit includes 2 armbands, 10 cassette holder 10 pouches containing one cassette of each of the following: chlorine/fluorine, hydrogen fluoride, diborane, high pH (base), hydrazine, hydrogen sulfide, iodine, low pH (acid), phosgene, phopshine and sulfur dioxide in a carrying case 085110 HazMat Detection Kit includes 2 extra long armbands, 10 cassette holder 10 pouches containing one cassette of each of the following: chlorine/fluorine, hydrogen fluoride, diborane, high pH (base), hydrazine, hydrogen sulfide, iodine, low pH (acid), phosgene, phosphine and sulfur dioxide in a carrying case 085110XL HazMat Refill Kit includes 10 cassettes each of acid, base, chlorine/fluorine, hydrogen fluoride, diborane, hydrazine, hydrogen sulfide, iodine, phosgene, phosphine, sulfur dioxide 085111 Methamphetamine Lab Detection Kit includes 2 Chameleon armbands, and 10 cassettes each of ammonia, hydrogen sulfide, iodine, low pH (acid) and phosphine in a carrying case 085120 Methamphetamine Lab Detection Kit includes 2 extra long Chameleon armbands, and 10 cassettes each of ammonia, hydrogen sulfide, iodine, low pH (acid) and phosphine & carrying case 085120XL Clan-Meth Lab Detection Cassette Refill Kit includes 10 cassettes each of low pH (acid), ammonia, iodine, phosphine and hydrogen sulfide 085121 Chemical Suicide Detection Cassette Refill Kit includes 10 cassettes each of high pH (base), low pH (acid), sulfur dioxide, phosphine and hydrogen sulfide 085141 Chemical Suicide Detection Kit includes 2 armbands, and 10 cassettes of high pH (acid), hydrogen sulfide, low pH (base), phosgene, sulfur dioxide & carrying case 085140 Chemical Suicide Detection Kit includes 2 extra long armbands, and 10 cassettes of high pH (acid), hydrogen sulfide, low pH (base), phosgene, sulfur dioxide & carrying case 085140XL Arson Investigation Kit includes 2 Chameleon armbands and 10 cassettes each of ammonia, low pH, hydrogen cyanide, hydrogen fluoride, hydrogen sulfide, nitrogen dioxide, phosgene and sulfur dioxide and carrying case 085190 Arson Investigation Kit includes 2 Chameleon XL armbands and 10 cassettes each of ammonia, low pH, hydrogen cyanide, hydrogen fluoride, hydrogen sulfide, nitrogen dioxide, phosgene and sulfur dioxide and carrying case 085190XL Arson Investigation Cassette Refill Kit includes 10 cassettes each of ammonia, low pH, hydrogen cyanide, hydrogen fluoride, hydrogen sulfide, nitrogen dioxide, phosgene and sulfur dioxide 085191 Training Kit includes 1 armband with 10 inactive cassettes, 50 training cassettes and 50 ampules 085130 Training Kit replacement includes 50 training cassettes and 50 ampules 085131 Chameleon Armband, 10 cassette holder, pk/5 085000 Chameleon Armband, 10 cassette holder, pk/5, extra long 085000XL Acid Cassette, pk/50 084005-50 Ammonia Cassette, pk/50 084015-50 Base Cassette, pk/50 084020-50 Hydrogen Sulfide Cassette, pk/50 084030-50 Iodine Cassette, pk/50 084052-50 Chlorine/Fluorine Cassette, pk/50 084035-50 Phosgene Cassette, pk/50 084060-50 Phosphine Cassette, pk/50 084061-50 Sulfur Dioxide Cassette, pk/50 084065-10 Diborane Cassette, pk/50 084040-50 Hydrazine Cassette, pk/50 084045-50 Hydrogen Cyanide 084048-50 Hydrogen Fluoride 084049-50 Nitrogen Dioxide 084054-50 Downloads Chameleon Technical literature Chameleon Colorimetric Badge literature Meth Lab literature Acid Cassette instructions Base Cassette instructions Hydrogen Sulfide Cassette instructions Chlorine/Fluorine Cassette instructions Phosgene Cassette instructions Ammonia Cassette instructions Diborane Cassette instructions Hydrazine Cassette instructions Iodine Cassette instructions Phosphine Cassette instructions Sulfur Dioxide Cassette instructions Hydrogen Cyanide instructions Hydrogen Fluoride instructions Nitrogen Dioxide instructions
Manufacturer: Morphix Technologies
Brand: Colorimetric Badges
Model: Chameleon
Short Description:

The Chameleon is the most innovative hazardous chemical detection device on the market today! Morphix Technologies has revolutionized simple color change technology and made it rugged to meet the needs of First Responders and military personnel.

ChromAir Direct Read Colorimetric Badges from Morphix Technologies
The ChromAir badge is a colorimetric direct read monitor and a color comparison chart. It relies on the principle of diffusion, therefore it requires no pump to operate. Unlike traditional diffusion tubes, the patented design of the ChromAir badge provides a short and constant diffusion path irrespective of the sampling time or concentration of the contaminant. This unique feature provides accurate results immediately and throughout the sampling period. The ChromAir monitor provides the user with six exposure levels*. Most ChromAir badges indicate from 1/10 to 2 times the time weighted average for an eight hour work period. The scale** printed on the badges and color comparators is based on exposure dose (parts per million time hour (ppm x hr). To determine the average concentration, the user locates the highest cell with a color changes and divides the corresponding dose level (ppm x hr) by the sampling time in hours (hrs). If the sampling time is 2 hours and badge reads 40 ppm x hr, the average concentration is 20 ppm. For higher resolution and wider range, the ChromAir badge may be used in conjunction with the ChromAir color comparator. The color scales on the color comparators identically match the colors formed on the ChromAir badges. Features Immediate on-site results Easy to read color change Highly sensitive and selective Exposure data read directly from badge Immediate response for short term exposure measurements Measures TWA exposures No laboratory analysis needed Lightweight and cost effective for personnel and area monitoring *The ChromAir mercury and glutaraldehyde badges have five levels. **The ChromAir mercury badge scale is mg/m3 x hr. The glutaraldehyde STEL badge is in ppm. Ordering Information For more information on each individual badge, click on the catalog number for a pdf. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Analyte Range(ppm x hr) Min. Detectable Concentration in 8 hours*** Interferences Catalog No. Acetone 20-24,000 2.5 ppm NH3, MEK, MIBK, MPK 380020-10 Ammonia 4-300 0.5 ppm RNH2 380003-10 Carbon Monoxide 10-525 1.25 ppm Alkenes, H2, H2S 380008-10 Chlorine 0.4-13 0.05 ppm Br2, I2 380004-10 Formaldehyde 0.3-12 0.04 ppm None Known 380007-10 Glutaraldehyde STEL (15 min) 0.04-0.95 ppm None Known 380017-10 Mercury 0.125-1.6 mg/m3 x hr 0.02 mg/m3 Strong Oxidizers 380018-10 Methyl Ethyl Ketone 18-21,600 2.25 ppm NH3, acetone, MIBK, MPK 380020-10 Methyl Isobutyl Ketone 16-19,200 2.0 ppm NH3, MEK, Acetone, MPK 380020-10 Ozone 0.08-1.6 0.01 ppm H2O2, NO2** 380010-10 *3 ppm H2S causes color development in cell 1, 10 ppm H2S causes color development in cell 2. **Ozone monitor is ten times more sensitive to ozone than to nitrogen dioxide. ***Coefficient must be applied to scale printed on badge. Color Comparators Description Catalog No. Carbon Monoxide Color Comparator 348006 Formaldehyde Color Comparator 384001 Downloads Chromair Badge Literature Response Time and Interchangeability Effects on the Tube-Like and the Badge-Like Passive Direct-Read Monitors Direct-Read Monitoring System for Carbon Monoxide Personal Monitoring in the Workplace
Manufacturer: Morphix Technologies
Brand: Colorimetric Badges
Model: ChromAir
Short Description:

The ChromAir badge is a colorimetric direct read monitor and a color comparison chart. It relies on the principle of diffusion, therefore it requires no pump to operate.

SafeAir Direct Read Colorimetric Badges from Morphix Technologies
The SafeAir Badge provides an immediate visual indication when a specific chemical hazard is present. The sensor in the SafeAir badge is constructed from a coated indicator layer rather than impregnated paper. This provides a homogeneous and stable color formation. The indicator layers are highly sensitive and selective to the targeted chemicals. A color change, in the form of an “exclamation point”, warns the presence of the targeted hazard. SafeAir is a low cost chemical detector badge allowing companies to perform daily exposure screening. The badge requires minimal training. There is no calibration, extra equipment or laboratory analysis required. Features Provides immediate visual indication when specific chemical is present. Homogeneous and stable color formation due to coated indicator layer Highly sensitive and selective Ideal for leak detection and daily exposure screening No laboratory analysis required The dual purpose badge is available for chlorine and chlorine dioxide which often coexist in the same environment. This badge selectively indicates the presence of chlorine on the front side of the badge and chlorine dioxide on the back side. Indications may appear on both sides if both chemicals are present. The mercury and 1,1-dimethyl hydrazine badges provide the user with two independent threshold levels. The front of the badge indicates one threshold level while the back provides a second level. This unique feature allows the badge to be used as an inexpensive range finder. For higher resolution and wider range, the SafeAir badge may be used in conjunction with the SafeAir Color Comparator. The color scales on the color comparators identically match the colors formed on the SafeAir badges. Specifications For more information on each individual badge, click on the catalog number for a pdf. Analyte Threshold Level Min Detectable Conc in 8 Hrs (ppm) MRST* (Hrs) SRST** (Mins) Cross Sensitivity Ammonia 4 ppm x hr 0.5 ppm 48 15 Aliphatic amines Carbon Monoxide 7 ppm x hr 0.9 ppm 10 15 Alkenes, H2, H2S Chlorine 0.18 ppm x hr 0.023 ppm 48 15 Br2, HCl, I2 Chlorine/ Chlorine dioxide Cl2: 0.18 ppm x hr Cl2: 0.025 ppm 10 15 Cl2: Br2, HCl, I2 ClO2: 0.2 ppm x hr ClO2: 0.025 ppm ClO2: NO2, high conc O3 Formaldehyde 0.2 ppm x hr 0.05 ppm 16 15 Acrolein Hydrazine 8 ppb x hr 1 ppb 48 5 MMH, Aromatic Amines Hydrogen Chloride 2 ppm – 15 min 15 None Known Hydrogen Sulfide 2 ppm x hr 0.25 ppm 48 15 None Known Mercury/Dual Level Front: 0.25 mg/m3 x hr Front: 0.031 mg/m3 48 15 Strong oxidizers Back: 0.08 mg/m3 x hr Back: 0.01 mg/m3 MDI 3.5 ppb x hr 0.4 ppb 24 15 Aromatic Diisocyantes, Hydrazines Ozone 0.05 ppm x hr 0.006 ppm 48 15 H2O2 above 1 ppm NO2 Phosgene 8.3 ppb x hr 0.001 ppm 72 1 Caronyl bromide, Chloroformates Phosgene Dura 20 ppb x hr – 120 1 Caronyl bromide, Chloroformates Phosgene Medi 166.7 ppb x hr – 120 1 Caronyl bromide, Chloroformates Sulfur Dioxide 0.2 ppm x hr 0.025 ppm 48 15 None Known TDI 5.0 ppb x hr 0.6 ppb 24 15 Aromatic Diisocyanate Hydrazine *Maximum recommended sampling time **Shortest recommended sampling time Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Ammonia SafeAir Badges, pk/50 382010-50 Carbon Monoxide SafeAir Badges, pk/50 382012-50 Chlorine SafeAir Badges, pk/50 382009-50 Chlorine/Chlorine Dioxide SafeAir Badges, pk/50 382003-50 Formaldehyde SafeAir Badges, pk/50 382011-50 Hydrazine SafeAir Badges, pk/50 382002-50 Hydrogen Chloride SafeAir Badges, pk/50 382024-50 Hydrogen Sulfide SafeAir Badges, pk/50 382015-50 Mercury/Dual Level SafeAir Badges, pk/50 382005-50 Aromatic Isocyanates SafeAir Badges, pk/50 382001-50 Ozone SafeAir Badges, pk/50 382004-50 Phosgene SafeAir Badges, pk/50 382036-50 Phosgene SafeAir Dura Badge, pk/50 382065-50 Phosgene SafeAir Medi Badge, pk/50 382060-50 Sulfur Dioxide SafeAir Badges, pk/50 382014-50 Color Comparators Description Catalog No. Chlorine Color Comparator 383010 Hydrazine Color Comparator 383001 Hydrogen Chloride Color Comparator 383008 Phosgene Color Comparator 383016 Phosgene Dura Color Comparator 383022 Phosgene Medi Color Comparator 383020 TDI Color Comparator 383005 Downloads Safeair Colorimetric Badge Literature Response Time and Interchangeability Effects on the Tube-Like and the Badge-Like Passive Direct-Read Monitors Direct-Read Monitoring System for Carbon Monoxide Personal Monitoring in the Workplace
Manufacturer: Morphix Technologies
Brand: Colorimetric Badges
Model: SafeAir
Short Description:

The SafeAir Badge provides an immediate visual indication when a specific chemical hazard is present. The sensor in the SafeAir badge is constructed from a coated indicator layer rather than impregnated paper.