Personal Sample Pumps


Air Sample Pumps / Personal Sampling Pumps

Personal sampling pumps for particulates in the breathing zone.

4
Yes
None
1
60
Search...
/air-sampling-equipment/personal-sample-pumps/
Thumbnail
Sort By:

Categories:

Tags:

Manufacturer:

Model:

Short Description:

' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series D12 gas transmitter product line has been expanded. Now available in this versatile package is an LEL transmitter utilizing an Infrared sensor that resists the poisoning problems inherent in catalytic bead sensors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series PQ45 is the answer to the need for a rugged field deployed package capable of measuring and recording water quality data in a variety of operating environments.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Allegro's Air Filtration Panels convert shop air used for pneumatic tools and equipment to clean breathable air.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Area monitoring reinvented. That's what Draeger's X-zone 5500 brings to a worksite: a safer, more effective way to monitor for hazardous gases. In combination with the Draeger X-am 5000, 5100 or 5600 gas detection instruments, the X-zone 5500 can be used for the measurement of up to six gases and extends the range of your portable gas detection technology.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Breathe cool, stay safe: Draeger X-plore 1750 and 1760 is Draeger's new generation particle filtering face piece respirators, coming with distinct improvements in comfort and protection.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Combining versatility, ease of use and the latest breathing apparatus design, Draeger's PAS Micro is among the most technologically advanced, short duration emergency escape units available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Draeger's PAS Colt combines versatility, ease of use and the latest in breathing apparatus design. It is among the most technologically advanced, short duration emergency escape unit available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ER2000 Escape Respirator is a hood style full face respirator that provides respiratory protection from Nuclear, Biological and Chemical (NBC) warfare agents as well as Toxic Industrial Materials (TIM's).

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

FMC 2000 is a multi-channel controller with built in modem designed for integration with Rae Systems' wireless mesh network products. It is simple to install and operate, versatile, and dependable.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

For qualitative fit testing of air purifying respirators this Smoke Test Kit offers everything needed for meeting OSHA's protocol for fit testing with smoke.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Perfect for storing APR's cartridges and other respirator accessories such as fit testing kits, storage bags and cleaning supplies.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' Hand pump if for use with Rae's line of gas detection tubes.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' MultiRae Lite is a perfect wireless monitoring solution for personal protection. It can monitor up to six gases and thrives in confined space entry situations. This tool comes in either with an internal pump or diffusion monitor and is compatible with more than 30 sensor options allowing it to fully meet the monitoring requirements of any application.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' large selection of colorimetric gas detection tubes offer quick, on the spot measurements of a wide range of toxic and combustible gases and vapors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' ppbRae 3000 is a state of the art VOC gas detector for monitoring at the parts per billion (ppb) level. This device uses a new generation of photo ionization detector (PID) and features both temperature and humidity compensation for improved accuracy. It includes built in correction factors for over 200 compounds and is suitable for use in any hazardous environment.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Casella dBadge2 Noise Dosimeter keeps all the great attributes of the original dBadge but adds incredible features you won't want to do without!

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Draeger single cartridge system keeps cartridges and filters out of the wearer's line of vision without sacrificing service life or breathing comfort. the threaded adapter on the cartridges makes change out simple, quick and sure.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The GfG G460 combustible gas detector is the world's most advanced multi-sensor atmospheric monitor. The durable G460 continuously measures and displays readings for up to six gases at the same time.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae 2000 is no longer available. The MiniRae 3000+ has replaced the MiniRae 2000. The MiniRae 3000+ is Rae Systems most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae Lite from Rae Systems is the most reliable handheld portable volatile organic compound (VOC) monitor on the market. Its photo ionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for application ranging from environmental to construction.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Rae Systems MultiRae Pro is the industry's first wireless multi threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs), toxic, combustible gases and oxygen with Man Down Alarm functionality in one highly portable instrument.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The ToxiRae Pro is the world's first wireless personal monitor for toxic gases and oxygen. The Rae Systems ToxiRae Pro takes worker protection to the next level by providing safety professionals wireless access to real time instrument readings and alarm status (including man down alarm) from any location for better visibility and faster response.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The use of ozone gas is increasing rapidly in a wide variety of applications, such as water treatment, odor control and food processing. ATI's Model A23-14 is a portable generator designed to produce an ozone gas concentration below 1 ppm.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This Point of Attachment (POA) Air Control System connects to any breathing air source. It's housed in a Pelican carry case that can be wall mounted and includes an adjustable pressure regulator, pressure gauge and a pressure relief valve.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This heat stress meter features bright multi-color LCD backlights corresponding to OSHA's heat stress alert levels.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This unique sound meter enables remote sound level readings using a detachable probe. It features an RS232 computer interface, AC output and a coiled probe that extends to 9'.

' class='jquery-prod-cf-value' />
Flow Detective Digital Air Flow Meter
The Flow Detective Digital Air Flow Meter is designed with ruggedness an accuracy in mind. With Casella’s world renowned ease of use, calibration of air sampling pumps just got quicker and easier. The Flow Detective has been designed to be rugged, with no moving parts so it can be used in the field. Performing calibrations is quick and easy, with a simple user interface and color screen that can be easily viewed from a distance. With the longest battery life on the market, there is peace of mind that it is always ready to go. Within a few seconds of switching on the Flow Detective, is ready to measure, ensuring you can calibrate devices quickly. With it’s wide flow range, as well as calibrating dust sampling heads, it can be used to calibrate at low flows for sorbent tube sampling, ensuring you just need one device for all personal air sampling calibration. The Flow Detective calibrates within 2% accuracy, has a 70 hour battery life and flow ranges of 20ml/min to 5,00ml/min. As pumps generally use a moving diaphragm, this creates fluctuations in the flow rate on a pump. As sampling heads like cylcones rely on a steady flow to maintain a specific size cut, it is important for pulsation to be as small as possible. Thee flow Detective display a red indicator if pulsation is above 10% When calibrating any device, the Airwave App can be used to remotely control the Flow Detective and wirelessly receive calibration data. When used with an Apex2 pump closed loop calibration can be achieved so nothing has to be set manually on the pump which saves time. The Airwave App allows calibration data to be sent from you mobile device’s email client. This allows you to get calibration traceability data quickly, both before taking a sample run with a pump and after the sampling period to verify flow is within 5%. The Plus calibrator features low flow calibration, Bluetooth connectivity and closed loop calibration with the Apex2 pumps.

Features

  • High accuracy calibration
  • Pulsation detection
  • Simple operation
  • Rugged design
  • Long battery life
  • Wide flow measurement
  • Bluetooth connectivity
  • Closed loop, wireless calibration with Apex2 pumps

Specifications

Flow Range Normal: 500 to 5,000 ml/min Low: 20 to 500 ml/min
Accuracy <±2% from 500 to 5,000 ml/min ±0.8% of reading ±0.2% FSD from 20 to 500 ml/min
Pulsation Indicator Flashes when pulsation is >10%
Flow Modes Standard or Actual Fold
Volume Units ml/min, L/min, cF/min, cc/min
Temperature Units C, F, K
Pressure Units kPa, mmHg, H2O, cmH2O, mBar, PSI
Display Color OLED
Controls 4 buttons
Warm Up Time <1 second
Temperature 0-45°C
Humidity 30-95% rH
Barometric Pressure Auto-correcting
Battery Rechargeable li-Ion
Battery Level Indicator Yes
Battery Life >70 hours
Charge Time Typically <6 hours
Dimensions 4.41 x 1.46 x 4.02″
Weight 13 ounces

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Flow Detective Digital Flowmeter Kit includes calibrator, docking station, inhalable sampler adapter and case FlowDetective Kit
Flow Detective Plus Kit includes calibrator, docking station, inhalable sample adapter and case
FlowDetectivePlus Kit

Downloads

Flow Detective Digital Flowmeter Literature Flow Detective Field Guide
Nextteq Gastec Continuous Sampling Tubes
Gastec Continuous Sampling Tubes can measure very low concentrations of odorants when used in conjunction with an auto gas sampler. (Note: The S-Series detector tubes cannot be used with the Gastec GV100 or GV110 Sampling Pumps.) The instruction sheets represented here are examples of the typical instructions for each part number. The actual instruction sheet found in each box of Gastec detector tubes may vary slightly for each lot number of detector tubes from the typical instruction sheet found here. FOR PROPER PERFORMANCE, CONSULT THE ACTUAL INSTRUCTIONS IN EACH BOX OF DETECTOR TUBES.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Gases & Vapors
Measuring Range
Catalog No.
Ammonia 0.5 – 5 ppm 3S
Benzene 250 – 3,000 mg/m3 121P
Formaldehyde 0.01 – 1.75 ppm 91TP
0.01 – 0.8 ppm 91PL
0.02 – 1.44 ppm 91P
Hydrogen Sulfide 10 – 200 ppb 4S
p-Dichlorobenzene 100 – 3,000 mg/m3 127P
Styrene 0.2 – 4 ppm 124S
Tetrachloroethylene 20 – 720 mg/m3 133P
Toluene 100 – 7,000 mg/m3 122P
Trichloroethylene 20 – 1,200 mg/m3 132P
Vinyl Chloride 50 – 1,500 mg/m3 131P
 
Flow Detective Digital Air Flow Meter
The Flow Detective Digital Air Flow Meter is designed with ruggedness an accuracy in mind. With Casella’s world renowned ease of use, calibration of air sampling pumps just got quicker and easier. The Flow Detective has been designed to be rugged, with no moving parts so it can be used in the field. Performing calibrations is quick and easy, with a simple user interface and color screen that can be easily viewed from a distance. With the longest battery life on the market, there is peace of mind that it is always ready to go. Within a few seconds of switching on the Flow Detective, is ready to measure, ensuring you can calibrate devices quickly. With it’s wide flow range, as well as calibrating dust sampling heads, it can be used to calibrate at low flows for sorbent tube sampling, ensuring you just need one device for all personal air sampling calibration. The Flow Detective calibrates within 2% accuracy, has a 70 hour battery life and flow ranges of 20ml/min to 5,00ml/min. As pumps generally use a moving diaphragm, this creates fluctuations in the flow rate on a pump. As sampling heads like cylcones rely on a steady flow to maintain a specific size cut, it is important for pulsation to be as small as possible. Thee flow Detective display a red indicator if pulsation is above 10% When calibrating any device, the Airwave App can be used to remotely control the Flow Detective and wirelessly receive calibration data. When used with an Apex2 pump closed loop calibration can be achieved so nothing has to be set manually on the pump which saves time. The Airwave App allows calibration data to be sent from you mobile device’s email client. This allows you to get calibration traceability data quickly, both before taking a sample run with a pump and after the sampling period to verify flow is within 5%. The Plus calibrator features low flow calibration, Bluetooth connectivity and closed loop calibration with the Apex2 pumps. Features High accuracy calibration Pulsation detection Simple operation Rugged design Long battery life Wide flow measurement Bluetooth connectivity Closed loop, wireless calibration with Apex2 pumps Specifications Flow Range Normal: 500 to 5,000 ml/min Low: 20 to 500 ml/min Accuracy <±2% from 500 to 5,000 ml/min ±0.8% of reading ±0.2% FSD from 20 to 500 ml/min Pulsation Indicator Flashes when pulsation is >10% Flow Modes Standard or Actual Fold Volume Units ml/min, L/min, cF/min, cc/min Temperature Units C, F, K Pressure Units kPa, mmHg, H2O, cmH2O, mBar, PSI Display Color OLED Controls 4 buttons Warm Up Time <1 second Temperature 0-45°C Humidity 30-95% rH Barometric Pressure Auto-correcting Battery Rechargeable li-Ion Battery Level Indicator Yes Battery Life >70 hours Charge Time Typically <6 hours Dimensions 4.41 x 1.46 x 4.02″ Weight 13 ounces Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Flow Detective Digital Flowmeter Kit includes calibrator, docking station, inhalable sampler adapter and case FlowDetective Kit Flow Detective Plus Kit includes calibrator, docking station, inhalable sample adapter and case FlowDetectivePlus Kit Downloads Flow Detective Digital Flowmeter Literature Flow Detective Field Guide
Manufacturer:
Brand:
Model:
Short Description:
Nextteq Gastec Continuous Sampling Tubes
Gastec Continuous Sampling Tubes can measure very low concentrations of odorants when used in conjunction with an auto gas sampler. (Note: The S-Series detector tubes cannot be used with the Gastec GV100 or GV110 Sampling Pumps.) The instruction sheets represented here are examples of the typical instructions for each part number. The actual instruction sheet found in each box of Gastec detector tubes may vary slightly for each lot number of detector tubes from the typical instruction sheet found here. FOR PROPER PERFORMANCE, CONSULT THE ACTUAL INSTRUCTIONS IN EACH BOX OF DETECTOR TUBES. Ordering Information Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Gases & Vapors Measuring Range Catalog No. Ammonia 0.5 – 5 ppm 3S Benzene 250 – 3,000 mg/m3 121P Formaldehyde 0.01 – 1.75 ppm 91TP 0.01 – 0.8 ppm 91PL 0.02 – 1.44 ppm 91P Hydrogen Sulfide 10 – 200 ppb 4S p-Dichlorobenzene 100 – 3,000 mg/m3 127P Styrene 0.2 – 4 ppm 124S Tetrachloroethylene 20 – 720 mg/m3 133P Toluene 100 – 7,000 mg/m3 122P Trichloroethylene 20 – 1,200 mg/m3 132P Vinyl Chloride 50 – 1,500 mg/m3 131P  
Manufacturer:
Brand:
Model:
Short Description: