4
Yes
None
1
60
Search...
/gas-detection-instruments/detector-tubes/tube-pumps/
Thumbnail
Sort By:

Categories:

Tags:

Manufacturer:

Model:

Short Description:

' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series D12 gas transmitter product line has been expanded. Now available in this versatile package is an LEL transmitter utilizing an Infrared sensor that resists the poisoning problems inherent in catalytic bead sensors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series PQ45 is the answer to the need for a rugged field deployed package capable of measuring and recording water quality data in a variety of operating environments.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Allegro's Air Filtration Panels convert shop air used for pneumatic tools and equipment to clean breathable air.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Area monitoring reinvented. That's what Draeger's X-zone 5500 brings to a worksite: a safer, more effective way to monitor for hazardous gases. In combination with the Draeger X-am 5000, 5100 or 5600 gas detection instruments, the X-zone 5500 can be used for the measurement of up to six gases and extends the range of your portable gas detection technology.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Breathe cool, stay safe: Draeger X-plore 1750 and 1760 is Draeger's new generation particle filtering face piece respirators, coming with distinct improvements in comfort and protection.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Combining versatility, ease of use and the latest breathing apparatus design, Draeger's PAS Micro is among the most technologically advanced, short duration emergency escape units available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Draeger's PAS Colt combines versatility, ease of use and the latest in breathing apparatus design. It is among the most technologically advanced, short duration emergency escape unit available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ER2000 Escape Respirator is a hood style full face respirator that provides respiratory protection from Nuclear, Biological and Chemical (NBC) warfare agents as well as Toxic Industrial Materials (TIM's).

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

FMC 2000 is a multi-channel controller with built in modem designed for integration with Rae Systems' wireless mesh network products. It is simple to install and operate, versatile, and dependable.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

For qualitative fit testing of air purifying respirators this Smoke Test Kit offers everything needed for meeting OSHA's protocol for fit testing with smoke.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Perfect for storing APR's cartridges and other respirator accessories such as fit testing kits, storage bags and cleaning supplies.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' Hand pump if for use with Rae's line of gas detection tubes.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' MultiRae Lite is a perfect wireless monitoring solution for personal protection. It can monitor up to six gases and thrives in confined space entry situations. This tool comes in either with an internal pump or diffusion monitor and is compatible with more than 30 sensor options allowing it to fully meet the monitoring requirements of any application.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' large selection of colorimetric gas detection tubes offer quick, on the spot measurements of a wide range of toxic and combustible gases and vapors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' ppbRae 3000 is a state of the art VOC gas detector for monitoring at the parts per billion (ppb) level. This device uses a new generation of photo ionization detector (PID) and features both temperature and humidity compensation for improved accuracy. It includes built in correction factors for over 200 compounds and is suitable for use in any hazardous environment.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Casella dBadge2 Noise Dosimeter keeps all the great attributes of the original dBadge but adds incredible features you won't want to do without!

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Draeger single cartridge system keeps cartridges and filters out of the wearer's line of vision without sacrificing service life or breathing comfort. the threaded adapter on the cartridges makes change out simple, quick and sure.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The GfG G460 combustible gas detector is the world's most advanced multi-sensor atmospheric monitor. The durable G460 continuously measures and displays readings for up to six gases at the same time.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae 2000 is no longer available. The MiniRae 3000+ has replaced the MiniRae 2000. The MiniRae 3000+ is Rae Systems most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae Lite from Rae Systems is the most reliable handheld portable volatile organic compound (VOC) monitor on the market. Its photo ionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for application ranging from environmental to construction.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Rae Systems MultiRae Pro is the industry's first wireless multi threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs), toxic, combustible gases and oxygen with Man Down Alarm functionality in one highly portable instrument.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The ToxiRae Pro is the world's first wireless personal monitor for toxic gases and oxygen. The Rae Systems ToxiRae Pro takes worker protection to the next level by providing safety professionals wireless access to real time instrument readings and alarm status (including man down alarm) from any location for better visibility and faster response.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The use of ozone gas is increasing rapidly in a wide variety of applications, such as water treatment, odor control and food processing. ATI's Model A23-14 is a portable generator designed to produce an ozone gas concentration below 1 ppm.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This Point of Attachment (POA) Air Control System connects to any breathing air source. It's housed in a Pelican carry case that can be wall mounted and includes an adjustable pressure regulator, pressure gauge and a pressure relief valve.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This heat stress meter features bright multi-color LCD backlights corresponding to OSHA's heat stress alert levels.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This unique sound meter enables remote sound level readings using a detachable probe. It features an RS232 computer interface, AC output and a coiled probe that extends to 9'.

' class='jquery-prod-cf-value' />
X-act 5000 Automatic Tube Pump for Draeger Tubes
The automatic X-act 5000 tube pump is the first all in one solution designed for measurements with Draeger short term tubes and for sampling tubes and systems. Ease of operation and a high degree of reliability compliment the measurement and sampling of gases, vapors and aerosols. The automatic tube pump is compatible with Draeger short term tubes as well as sampling tubes and systems. The robust housing supports the use of  the pump to perform the daily measuring tasks under tough conditions. The components of the pump are corrosion resistant and the pump is additionally equipped with a user replaceable filter which traps sulfur trioxide aerosols protecting the pump for up to two years. The display is backlit to enable use of the pump under poor lighting conditions. All Draeger short term tubes and accessories can be used with the Draeger X-act 5000. The IS approved Draeger X-act 5000 can be used for confined space applications and in explosive gas atmospheres – always ready wherever fast and reliable on-site measurements are required. The key principle is the ability to provide the required flow characteristics of the Draeger short term tubes, while also providing the option to be used with sampling tubes and systems requiring constant flow. Compared to the Draeger accuro hand pump, this new concept reduces the average measurement time of the Draeger short term tubes in case of a high number of strokes. The internal pump is also designed to use extension hoses up to a length of 30 M. The handling of gases, vapors and aerosols has never been easier. The automatic tube pump directs the air to be measured through the appropriate Draeger Tubes effortlessly. It is comfortably carried with one hand or using the shoulder strap and is easily operated, even wearing protective gloves. A simple and intuitive menu structure provides the user efficient operation with just a few button presses. Using the password protected menu repetitive operating modes can be set. A barcode printed on the label on the backside of a Draeger short term tube box contains all relevant measurement parameters. Simply sliding the barcode over the barcode reader of the pump, automatically transfers the name of the substance to be measured, the number of strokes and the measuring range of the display. The required steps to carry out the measurement are simplified with the X-act 5000 and the possibility of making an error is reduced to a minimum. Draeger short term tubes are calibrated for measurement in ambient air. To evaluate measurements in technical gases, the properties of the technical gas must be taken into consideration. Technical gases have a different viscosity than ambient air. Therefor, the flow of the pump must be set accordingly. Following the operating steps in the mode, Measurement in Technical Gases, the X-act 5000 will automatically be adjusted to the require flow parameter and the measurement result can be read directly. Depending on the sampling tubes or systems, the required parameters for the test can be set directly without the need for an external flowmeter. The X-act 5000 automatically adjusts the flowrate. After setting the sampling time the pump can immediately be started. At the end of the measurement the pump will stop automatically. The set data, the elapsed time and the pumped volume will be indicated on the display.

Specifications

Number of Strokes Adjustable, 1 to 199 strokes
Stroke Volume 100 ml
Flow Rate Range 0.1 to 2.0 LPM Resolution 0.1 to 1.0 LPM: 0.1 LPM ±5% Resolution 1.0 to 2.0 LPM: 0.2 LPM ±5%
Sampling Time Adjustable, up to 12 hours, depending on flow rate, resolution in steps of 15 min (default) or 1 min
Display 2 Parts: segment and matrix
Use of Extension Hose Up to 30 Meters
Operating Temperature 41 to 104°F
Relative Humidity 0 to 95% non-condensing
Battery NiMH, Charge Time <4 hours Alkaline: 6 AA cells
Battery Capacity > 1,000 strokes, sample taking: up to 12 hours, depending on adjusted flow rate
Size 7″ x 9″ x 4.5″
Weight 3.5 pounds
Approvals ATEX: Ex ia IIC T4 Ga, Ex ia I Ma, I M 1 / II 1 G UL: Class I, Div 1, Groups A, B, C, D, Class II, Div 1 Groups F, G, +5°C ≤ Ta ≤ 40°C Temp Doe T4 Exia IP 64

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
X-act 5000 Tube Pump includes shoulder strap, NiMH battery, charger 4523617
Shoulder Strap 4523565
Car Charger 4523511
Extension Hose, 1M includes Adapters 6400561
Extension Hose, 3 M includes Adapters 6400077
Extension Hose, 10M includes Adapters 6400078
Extension Hose, 15M includes Adapters 6400079
Extension Hose, 30M includes Adapters 6401175
Plug for Tube Tip Reservoir 4523560
X-act 5000 Calibration Tube 8103651
X-act 5000 Dosage Tube for Tech Gas 6527562

Downloads

X-Act 5000 Tube Pump Datasheet
Gastec Gas Sampling Pump for Fumigation
For over 40 years, the Gastec Pump & Tube System has provided fast, simple and precise measurement of select fumigation applications. The Gastec GV100X Pump was designed exclusively for fumigation applications and is only available for sale to fumigation end users. With the majority of standard measuring ranges requiring a 100ml , full pump stroke, there is less sampling time, less chance of errors, no miscalculated strokes and no miscompressions. No other manufacturer offers a pump designed exclusively for fumigation applications. The Gastec Fumigation Probe connects directly to a Gastec Fumigation Detector Tube and can be inserted directly into the rubber seal of a cargo container to measure fumigants.

Ordering Information

Please Note: This tube pump is for use with the tubes listed below only. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Gastec Fumigant Detector Tube Pump GV100X
Fumigation Probe 380

Accessory Ordering Information

Description
Catalog No.
Chloropicrin Detector Tube, 2.5-60 ppm, 5 tubes & 5 pretubes 134
Cloropicrin Detector Tube, 0.1-7.5 ppm, 5 tubes & 5 pretubes 134L
Dichlorvos Detector Tube, 0.05-3.2 ppm 132LL
Ethylene Oxide, 0.05-3% 163
Ethylene Oxide, 0.4-350 ppm 163L
Ethylene Oxide, 0.1-10 ppm 163LL
Methyl Bromide, 10-600 ppm 136H
Methyl Bromide, 2.5-200 ppm 136L
Methyl Bromide, 1-36 ppm 136LA
Methyl Bromide, 0.1-3.0 ppm 136LL
Methyl Iodide, 0-5-108 ppm 230
Methyl Iodide, 100-34,800 ppm 230H
Methyl Isothiocyanate 141L
1,3-Dichloropropene, 0-5-10 ppm 131LA
Phosphine, 2.5-1,000 ppm 7J
Phosphine, 2.5-100 ppm 7
Phosphine, 0.15-5 ppm 7L
Phosphine, 0.05-9.8 ppm 7LA
Phosphine, 200-5,500 ppm 7H
Sulfuryl Fluoride 231

Downloads

GasTec Fumigation Tube Pump Literature Pump Accessories Literature
Gastec Gas Sampling Pump for Gastec Detector Tubes

Packed with features, the standard Gastec Gas Sampling Pump is the only pump you need for measuring gas and vapor concentrations quickly and accurately. Small, lightweight, and rugged, this pump is perfectly calibrated, displays ambient temperature, and includes a lifetime warranty. It is simple, always ready, and intrinsically safe. The Gastec Detector Tube and Pump System has been designed specifically with the end user in mind to allow for ease of use without compromising safety.

Weighing only 8 ounces, the intrinsically safe pump can easily be transported to any test site. The pump body is contoured and covered with a soft elastomer for a comfortable, secure grip. The exterior of the pump is composed of a durable and non-corrosive plastic and synthetic rubber compound, effectively eliminating any risk of sparks should the pump system be accidentally be dropped into an explosive environment. The pump incorporates a built-in detector tube tip breaker with a durable diamond cutting edge. Discarded tips are deposited in a storage bin for easy disposal.

The fail-safe handle can be locked into two positions: the full stroke position for a sample volume of 100 ml or the half stroke position for a sample volume of 50 ml. Both positions are marked by means of an unambiguous red line thereby eliminating the chance of taking an incomplete pump stroke. The flow finish indicator in the handle ensures precise sampling volumes.

The pumps are the first and only gas sampling pumps to provide on-the-spot measurement of ambient temperature. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of Gastec Gas Sampling Pumps and accurately displaying ambient temperature. The Thermal Ring reduces the risk of error and increases safety by enabling users to correct for temperature variances on the spot.

Gastec Gas Sampling Pumps can only be used with Gastec Detector Tubes. Gastec products are designed, manufactured, and calibrated to work together to ensure accurate readings. To maintain the highest level of quality, Gastec products are manufactured in ISO-9001 certified facilities.

The GV-100 pump is also available with a One-Hand Adapter. Gastec’s One-Hand Adapter converts the Gastec Gas Sampling Pump from one-stroke piston action to one-button operation. One-button/one-hand operation makes it perfect for sampling in awkward places, such as a confined space while standing on a ladder.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Gastec Detector Tube Pump includes thermal ring, case, spare parts kit, and handbook GV-100-S-TR
Gastec Detector Tube Pump with One Hand Adapter includes thermal ring, case, spare parts kit and handbook GV-100-SOHA-TR

Accessory Ordering Information

Description
Catalog No.
Hot Probe 340
Hot Probe Holder 345A
Extension Hose, 5M with rubber shroud tube holder 350A
Extension Hose, 10M with rubber shroud tube holder 350A-10
Telescoping Extension Pole 350BP
Extension Hose, 30M 351A-30
Gastec Deluxe Tube Tip Breaker 722

Downloads

Gastec Pump Literature

Pump Accessories Literature

Thermal Ring Literature

Gastec Gas Sampling Pump with Stroke Counter for Gastec Detector Tubes

Packed with features, the standard Gastec Gas Sampling Pump is the only pump you need for measuring gas and vapor concentrations quickly and accurately. Small, lightweight, and rugged, this pump is perfectly calibrated, displays ambient temperature, and includes a lifetime warranty. It is simple, always ready, and intrinsically safe.

Although over 85% of Gastec detector tubes require only 1 or 2 pump strokes, the GV-110’s built-in counter eliminates the risk of miscounting when using tubes that require additional strokes. The counter automatically tracks up to 10 pump strokes on an easy-to-read dial. For accurate gas measurements, it is important to complete the correct number of pump strokes. The GV-110 with stroke counter will automatically provide an accurate tally. After sampling, the counter can be reset to zero with a simple twist of the dial.

The Gastec Detector Tube and Pump System has been designed specifically with the end user in mind to allow for ease of use without compromising safety. Weighing only 9.4 ounces (266.5 grams), the intrinsically safe pump can easily be transported to any test site. The pump body is contoured and covered with a soft elastomer for a comfortable, secure grip. The exterior of the pump is composed of a durable and non-corrosive plastic and synthetic rubber compound, effectively eliminating any risk of sparks should the pump system be accidentally be dropped into an explosive environment.

The pump incorporates a built-in detector tube tip breaker with a durable diamond cutting edge. Discarded tips are safely deposited in a storage bin for easy disposal.

The fail-safe handle can be locked into two positions: the full stroke position for a sample volume of 100 ml or the half stroke position for a sample volume of 50 ml. Both positions are marked by means of an unambiguous red line thereby eliminating the chance of taking an incomplete pump stroke. The flow finish indicator in the handle ensures precise sampling volumes.

This pump is the first and only gas sampling pumps to provide on-the-spot measurement of ambient temperature. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of Gastec Gas Sampling Pumps and accurately displaying ambient temperature. The Thermal Ring reduces the risk of error and increases safety by enabling users to correct for temperature variances on the spot.

Gastec Gas Sampling Pumps can only be used with Gastec Detector Tubes. Gastec products are designed, manufactured, and calibrated to work together to ensure accurate readings. To maintain the highest level of quality, Gastec products are manufactured in ISO-9001 certified facilities.

The GV-110 pump is also available with a One-Hand Adapter. Gastec’s One-Hand Adapter converts the Gastec Gas Sampling Pump from one-stroke piston action to one-button operation. One-button/one-hand operation makes it perfect for sampling in awkward places, such as a confined space while standing on a ladder.

Small, lightweight, and easy-to-use, the One-Hand Adapter easily attaches to the end of the Gastec GV-110 pump and doesn’t interfere with normal functionality of the pump. To prepare for the sample, simply insert a detector tube, prime the gas sampling pump using two hands, and lock into place. To take a sample, just push the red button.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Gastec Detector Tube Pump with Stroke Counter includes thermal ring, case, spare parts kit, and handbook GV-110-S-TR
Gastec Detector Tube Pump with One Hand Adapter and Stroke Counter includes thermal ring, case, spare parts kit and handbook GV-110-SOHA-TR

Accessory Ordering Information

Description
Catalog No.
Hot Probe 340
Hot Probe Holder 345A
Extension Hose, 5M with rubber shroud tube holder 350A
Extension Hose, 10M with rubber shroud tube holder 350A-10
Telescoping Extension Pole 350BP
Extension Hose, 30M 351A-30
Gastec Deluxe Tube Tip Breaker 722

Downloads

Gastec Pump Literature

Pump Accessories Literature

Thermal Ring Literature

Piston Sample Pump from Rae Systems

Rae Systems’ by Honeywell Hand pump if for use with Rae’s line of gas detection tubes. The hand pump, along with the tubes, offers quick, on-the-spot measurements of many gases and vapors at low cost without the need for calibration.

Features

  • Solid metal construction with Rae Systems’ exclusive lifetime warranty
  • Spring-less piston design for accurate 50 and 100 cc volumes
  • Tube tip breaker and glass tip holder
  • Clear end-of-flow indicator
  • Tapered inlet design avoids leaks with different diameter tubes
  • Simple stroke counter
  • Additional accessories include remote sampling hoses with 15′ (5 m) or 35′ (11 m) lengths

Ordering Information

Each Piston Pump Kit includes the pump, spare inlet filters, spare rubber inlet, spare plunger gasket and case. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Piston Pump, only
010-0901-000
Piston Pump Kit
010-0001-000

Accessory Ordering Information

Description
Catalog No.
Remote Sampling Hose, 5M
010-3009-015
Remote Sampling Hose, 11M
010-3009-035
Colorimetric Tube Reader
010-2007-000
Tube Handbook
010-4003-000
Tube Breaker
010-2003-000

Downloads

Piston Pump Operation & Maintenance Instructions

X-act 5000 Automatic Tube Pump for Draeger Tubes
The automatic X-act 5000 tube pump is the first all in one solution designed for measurements with Draeger short term tubes and for sampling tubes and systems. Ease of operation and a high degree of reliability compliment the measurement and sampling of gases, vapors and aerosols. The automatic tube pump is compatible with Draeger short term tubes as well as sampling tubes and systems. The robust housing supports the use of  the pump to perform the daily measuring tasks under tough conditions. The components of the pump are corrosion resistant and the pump is additionally equipped with a user replaceable filter which traps sulfur trioxide aerosols protecting the pump for up to two years. The display is backlit to enable use of the pump under poor lighting conditions. All Draeger short term tubes and accessories can be used with the Draeger X-act 5000. The IS approved Draeger X-act 5000 can be used for confined space applications and in explosive gas atmospheres – always ready wherever fast and reliable on-site measurements are required. The key principle is the ability to provide the required flow characteristics of the Draeger short term tubes, while also providing the option to be used with sampling tubes and systems requiring constant flow. Compared to the Draeger accuro hand pump, this new concept reduces the average measurement time of the Draeger short term tubes in case of a high number of strokes. The internal pump is also designed to use extension hoses up to a length of 30 M. The handling of gases, vapors and aerosols has never been easier. The automatic tube pump directs the air to be measured through the appropriate Draeger Tubes effortlessly. It is comfortably carried with one hand or using the shoulder strap and is easily operated, even wearing protective gloves. A simple and intuitive menu structure provides the user efficient operation with just a few button presses. Using the password protected menu repetitive operating modes can be set. A barcode printed on the label on the backside of a Draeger short term tube box contains all relevant measurement parameters. Simply sliding the barcode over the barcode reader of the pump, automatically transfers the name of the substance to be measured, the number of strokes and the measuring range of the display. The required steps to carry out the measurement are simplified with the X-act 5000 and the possibility of making an error is reduced to a minimum. Draeger short term tubes are calibrated for measurement in ambient air. To evaluate measurements in technical gases, the properties of the technical gas must be taken into consideration. Technical gases have a different viscosity than ambient air. Therefor, the flow of the pump must be set accordingly. Following the operating steps in the mode, Measurement in Technical Gases, the X-act 5000 will automatically be adjusted to the require flow parameter and the measurement result can be read directly. Depending on the sampling tubes or systems, the required parameters for the test can be set directly without the need for an external flowmeter. The X-act 5000 automatically adjusts the flowrate. After setting the sampling time the pump can immediately be started. At the end of the measurement the pump will stop automatically. The set data, the elapsed time and the pumped volume will be indicated on the display. Specifications Number of Strokes Adjustable, 1 to 199 strokes Stroke Volume 100 ml Flow Rate Range 0.1 to 2.0 LPM Resolution 0.1 to 1.0 LPM: 0.1 LPM ±5% Resolution 1.0 to 2.0 LPM: 0.2 LPM ±5% Sampling Time Adjustable, up to 12 hours, depending on flow rate, resolution in steps of 15 min (default) or 1 min Display 2 Parts: segment and matrix Use of Extension Hose Up to 30 Meters Operating Temperature 41 to 104°F Relative Humidity 0 to 95% non-condensing Battery NiMH, Charge Time <4 hours Alkaline: 6 AA cells Battery Capacity > 1,000 strokes, sample taking: up to 12 hours, depending on adjusted flow rate Size 7″ x 9″ x 4.5″ Weight 3.5 pounds Approvals ATEX: Ex ia IIC T4 Ga, Ex ia I Ma, I M 1 / II 1 G UL: Class I, Div 1, Groups A, B, C, D, Class II, Div 1 Groups F, G, +5°C ≤ Ta ≤ 40°C Temp Doe T4 Exia IP 64 Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. X-act 5000 Tube Pump includes shoulder strap, NiMH battery, charger 4523617 Shoulder Strap 4523565 Car Charger 4523511 Extension Hose, 1M includes Adapters 6400561 Extension Hose, 3 M includes Adapters 6400077 Extension Hose, 10M includes Adapters 6400078 Extension Hose, 15M includes Adapters 6400079 Extension Hose, 30M includes Adapters 6401175 Plug for Tube Tip Reservoir 4523560 X-act 5000 Calibration Tube 8103651 X-act 5000 Dosage Tube for Tech Gas 6527562 Downloads X-Act 5000 Tube Pump Datasheet
Manufacturer:
Brand:
Model:
Short Description:
Gastec Gas Sampling Pump for Fumigation
For over 40 years, the Gastec Pump & Tube System has provided fast, simple and precise measurement of select fumigation applications. The Gastec GV100X Pump was designed exclusively for fumigation applications and is only available for sale to fumigation end users. With the majority of standard measuring ranges requiring a 100ml , full pump stroke, there is less sampling time, less chance of errors, no miscalculated strokes and no miscompressions. No other manufacturer offers a pump designed exclusively for fumigation applications. The Gastec Fumigation Probe connects directly to a Gastec Fumigation Detector Tube and can be inserted directly into the rubber seal of a cargo container to measure fumigants. Ordering Information Please Note: This tube pump is for use with the tubes listed below only. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Gastec Fumigant Detector Tube Pump GV100X Fumigation Probe 380 Accessory Ordering Information Description Catalog No. Chloropicrin Detector Tube, 2.5-60 ppm, 5 tubes & 5 pretubes 134 Cloropicrin Detector Tube, 0.1-7.5 ppm, 5 tubes & 5 pretubes 134L Dichlorvos Detector Tube, 0.05-3.2 ppm 132LL Ethylene Oxide, 0.05-3% 163 Ethylene Oxide, 0.4-350 ppm 163L Ethylene Oxide, 0.1-10 ppm 163LL Methyl Bromide, 10-600 ppm 136H Methyl Bromide, 2.5-200 ppm 136L Methyl Bromide, 1-36 ppm 136LA Methyl Bromide, 0.1-3.0 ppm 136LL Methyl Iodide, 0-5-108 ppm 230 Methyl Iodide, 100-34,800 ppm 230H Methyl Isothiocyanate 141L 1,3-Dichloropropene, 0-5-10 ppm 131LA Phosphine, 2.5-1,000 ppm 7J Phosphine, 2.5-100 ppm 7 Phosphine, 0.15-5 ppm 7L Phosphine, 0.05-9.8 ppm 7LA Phosphine, 200-5,500 ppm 7H Sulfuryl Fluoride 231 Downloads GasTec Fumigation Tube Pump Literature Pump Accessories Literature
Manufacturer:
Brand:
Model:
Short Description:
Gastec Gas Sampling Pump for Gastec Detector Tubes
Packed with features, the standard Gastec Gas Sampling Pump is the only pump you need for measuring gas and vapor concentrations quickly and accurately. Small, lightweight, and rugged, this pump is perfectly calibrated, displays ambient temperature, and includes a lifetime warranty. It is simple, always ready, and intrinsically safe. The Gastec Detector Tube and Pump System has been designed specifically with the end user in mind to allow for ease of use without compromising safety. Weighing only 8 ounces, the intrinsically safe pump can easily be transported to any test site. The pump body is contoured and covered with a soft elastomer for a comfortable, secure grip. The exterior of the pump is composed of a durable and non-corrosive plastic and synthetic rubber compound, effectively eliminating any risk of sparks should the pump system be accidentally be dropped into an explosive environment. The pump incorporates a built-in detector tube tip breaker with a durable diamond cutting edge. Discarded tips are deposited in a storage bin for easy disposal. The fail-safe handle can be locked into two positions: the full stroke position for a sample volume of 100 ml or the half stroke position for a sample volume of 50 ml. Both positions are marked by means of an unambiguous red line thereby eliminating the chance of taking an incomplete pump stroke. The flow finish indicator in the handle ensures precise sampling volumes. The pumps are the first and only gas sampling pumps to provide on-the-spot measurement of ambient temperature. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of Gastec Gas Sampling Pumps and accurately displaying ambient temperature. The Thermal Ring reduces the risk of error and increases safety by enabling users to correct for temperature variances on the spot. Gastec Gas Sampling Pumps can only be used with Gastec Detector Tubes. Gastec products are designed, manufactured, and calibrated to work together to ensure accurate readings. To maintain the highest level of quality, Gastec products are manufactured in ISO-9001 certified facilities. The GV-100 pump is also available with a One-Hand Adapter. Gastec’s One-Hand Adapter converts the Gastec Gas Sampling Pump from one-stroke piston action to one-button operation. One-button/one-hand operation makes it perfect for sampling in awkward places, such as a confined space while standing on a ladder. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Gastec Detector Tube Pump includes thermal ring, case, spare parts kit, and handbook GV-100-S-TR Gastec Detector Tube Pump with One Hand Adapter includes thermal ring, case, spare parts kit and handbook GV-100-SOHA-TR Accessory Ordering Information Description Catalog No. Hot Probe 340 Hot Probe Holder 345A Extension Hose, 5M with rubber shroud tube holder 350A Extension Hose, 10M with rubber shroud tube holder 350A-10 Telescoping Extension Pole 350BP Extension Hose, 30M 351A-30 Gastec Deluxe Tube Tip Breaker 722 Downloads Gastec Pump Literature Pump Accessories Literature Thermal Ring Literature
Manufacturer: Nextteq LLC
Brand: Gas Sampling Pump
Model: Gastec
Short Description:

Packed with features, the standard Gastec Gas Sampling Pump is the only pump you need for measuring gas and vapor concentrations quickly and accurately.

Gastec Gas Sampling Pump with Stroke Counter for Gastec Detector Tubes
Packed with features, the standard Gastec Gas Sampling Pump is the only pump you need for measuring gas and vapor concentrations quickly and accurately. Small, lightweight, and rugged, this pump is perfectly calibrated, displays ambient temperature, and includes a lifetime warranty. It is simple, always ready, and intrinsically safe. Although over 85% of Gastec detector tubes require only 1 or 2 pump strokes, the GV-110’s built-in counter eliminates the risk of miscounting when using tubes that require additional strokes. The counter automatically tracks up to 10 pump strokes on an easy-to-read dial. For accurate gas measurements, it is important to complete the correct number of pump strokes. The GV-110 with stroke counter will automatically provide an accurate tally. After sampling, the counter can be reset to zero with a simple twist of the dial. The Gastec Detector Tube and Pump System has been designed specifically with the end user in mind to allow for ease of use without compromising safety. Weighing only 9.4 ounces (266.5 grams), the intrinsically safe pump can easily be transported to any test site. The pump body is contoured and covered with a soft elastomer for a comfortable, secure grip. The exterior of the pump is composed of a durable and non-corrosive plastic and synthetic rubber compound, effectively eliminating any risk of sparks should the pump system be accidentally be dropped into an explosive environment. The pump incorporates a built-in detector tube tip breaker with a durable diamond cutting edge. Discarded tips are safely deposited in a storage bin for easy disposal. The fail-safe handle can be locked into two positions: the full stroke position for a sample volume of 100 ml or the half stroke position for a sample volume of 50 ml. Both positions are marked by means of an unambiguous red line thereby eliminating the chance of taking an incomplete pump stroke. The flow finish indicator in the handle ensures precise sampling volumes. This pump is the first and only gas sampling pumps to provide on-the-spot measurement of ambient temperature. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of Gastec Gas Sampling Pumps and accurately displaying ambient temperature. The Thermal Ring reduces the risk of error and increases safety by enabling users to correct for temperature variances on the spot. Gastec Gas Sampling Pumps can only be used with Gastec Detector Tubes. Gastec products are designed, manufactured, and calibrated to work together to ensure accurate readings. To maintain the highest level of quality, Gastec products are manufactured in ISO-9001 certified facilities. The GV-110 pump is also available with a One-Hand Adapter. Gastec’s One-Hand Adapter converts the Gastec Gas Sampling Pump from one-stroke piston action to one-button operation. One-button/one-hand operation makes it perfect for sampling in awkward places, such as a confined space while standing on a ladder. Small, lightweight, and easy-to-use, the One-Hand Adapter easily attaches to the end of the Gastec GV-110 pump and doesn’t interfere with normal functionality of the pump. To prepare for the sample, simply insert a detector tube, prime the gas sampling pump using two hands, and lock into place. To take a sample, just push the red button. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Gastec Detector Tube Pump with Stroke Counter includes thermal ring, case, spare parts kit, and handbook GV-110-S-TR Gastec Detector Tube Pump with One Hand Adapter and Stroke Counter includes thermal ring, case, spare parts kit and handbook GV-110-SOHA-TR Accessory Ordering Information Description Catalog No. Hot Probe 340 Hot Probe Holder 345A Extension Hose, 5M with rubber shroud tube holder 350A Extension Hose, 10M with rubber shroud tube holder 350A-10 Telescoping Extension Pole 350BP Extension Hose, 30M 351A-30 Gastec Deluxe Tube Tip Breaker 722 Downloads Gastec Pump Literature Pump Accessories Literature Thermal Ring Literature
Manufacturer: Nextteq LLC
Brand: Gas Sampling Pump
Model: Gastec with Stroke Counter
Short Description:

Packed with features, the standard Gastec Gas Sampling Pump is the only pump you need for measuring gas and vapor concentrations quickly and accurately.

Piston Sample Pump from Rae Systems
Rae Systems’ by Honeywell Hand pump if for use with Rae’s line of gas detection tubes. The hand pump, along with the tubes, offers quick, on-the-spot measurements of many gases and vapors at low cost without the need for calibration. Features Solid metal construction with Rae Systems’ exclusive lifetime warranty Spring-less piston design for accurate 50 and 100 cc volumes Tube tip breaker and glass tip holder Clear end-of-flow indicator Tapered inlet design avoids leaks with different diameter tubes Simple stroke counter Additional accessories include remote sampling hoses with 15′ (5 m) or 35′ (11 m) lengths Ordering Information Each Piston Pump Kit includes the pump, spare inlet filters, spare rubber inlet, spare plunger gasket and case. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Piston Pump, only 010-0901-000 Piston Pump Kit 010-0001-000 Accessory Ordering Information Description Catalog No. Remote Sampling Hose, 5M 010-3009-015 Remote Sampling Hose, 11M 010-3009-035 Colorimetric Tube Reader 010-2007-000 Tube Handbook 010-4003-000 Tube Breaker 010-2003-000 Downloads Piston Pump Operation & Maintenance Instructions
Manufacturer: Rae Systems Inc
Brand: Colorimetric Tube Pump
Model: LP-1200