Detector Tube Kits


Detector Tube Kits

Convenient tube kits designed for special applications include everything you need such as Draeger detector tubes and pumps.

4
Yes
None
1
60
Search...
/gas-detection-instruments/detector-tubes/detector-tube-kits/
Thumbnail
Sort By:

Categories:

Tags:

Manufacturer:

Model:

Short Description:

' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series D12 gas transmitter product line has been expanded. Now available in this versatile package is an LEL transmitter utilizing an Infrared sensor that resists the poisoning problems inherent in catalytic bead sensors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series PQ45 is the answer to the need for a rugged field deployed package capable of measuring and recording water quality data in a variety of operating environments.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Allegro's Air Filtration Panels convert shop air used for pneumatic tools and equipment to clean breathable air.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Area monitoring reinvented. That's what Draeger's X-zone 5500 brings to a worksite: a safer, more effective way to monitor for hazardous gases. In combination with the Draeger X-am 5000, 5100 or 5600 gas detection instruments, the X-zone 5500 can be used for the measurement of up to six gases and extends the range of your portable gas detection technology.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Breathe cool, stay safe: Draeger X-plore 1750 and 1760 is Draeger's new generation particle filtering face piece respirators, coming with distinct improvements in comfort and protection.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Combining versatility, ease of use and the latest breathing apparatus design, Draeger's PAS Micro is among the most technologically advanced, short duration emergency escape units available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Draeger's PAS Colt combines versatility, ease of use and the latest in breathing apparatus design. It is among the most technologically advanced, short duration emergency escape unit available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ER2000 Escape Respirator is a hood style full face respirator that provides respiratory protection from Nuclear, Biological and Chemical (NBC) warfare agents as well as Toxic Industrial Materials (TIM's).

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

FMC 2000 is a multi-channel controller with built in modem designed for integration with Rae Systems' wireless mesh network products. It is simple to install and operate, versatile, and dependable.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

For qualitative fit testing of air purifying respirators this Smoke Test Kit offers everything needed for meeting OSHA's protocol for fit testing with smoke.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Perfect for storing APR's cartridges and other respirator accessories such as fit testing kits, storage bags and cleaning supplies.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' Hand pump if for use with Rae's line of gas detection tubes.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' MultiRae Lite is a perfect wireless monitoring solution for personal protection. It can monitor up to six gases and thrives in confined space entry situations. This tool comes in either with an internal pump or diffusion monitor and is compatible with more than 30 sensor options allowing it to fully meet the monitoring requirements of any application.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' large selection of colorimetric gas detection tubes offer quick, on the spot measurements of a wide range of toxic and combustible gases and vapors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' ppbRae 3000 is a state of the art VOC gas detector for monitoring at the parts per billion (ppb) level. This device uses a new generation of photo ionization detector (PID) and features both temperature and humidity compensation for improved accuracy. It includes built in correction factors for over 200 compounds and is suitable for use in any hazardous environment.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Casella dBadge2 Noise Dosimeter keeps all the great attributes of the original dBadge but adds incredible features you won't want to do without!

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Draeger single cartridge system keeps cartridges and filters out of the wearer's line of vision without sacrificing service life or breathing comfort. the threaded adapter on the cartridges makes change out simple, quick and sure.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The GfG G460 combustible gas detector is the world's most advanced multi-sensor atmospheric monitor. The durable G460 continuously measures and displays readings for up to six gases at the same time.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae 2000 is no longer available. The MiniRae 3000+ has replaced the MiniRae 2000. The MiniRae 3000+ is Rae Systems most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae Lite from Rae Systems is the most reliable handheld portable volatile organic compound (VOC) monitor on the market. Its photo ionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for application ranging from environmental to construction.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Rae Systems MultiRae Pro is the industry's first wireless multi threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs), toxic, combustible gases and oxygen with Man Down Alarm functionality in one highly portable instrument.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The ToxiRae Pro is the world's first wireless personal monitor for toxic gases and oxygen. The Rae Systems ToxiRae Pro takes worker protection to the next level by providing safety professionals wireless access to real time instrument readings and alarm status (including man down alarm) from any location for better visibility and faster response.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The use of ozone gas is increasing rapidly in a wide variety of applications, such as water treatment, odor control and food processing. ATI's Model A23-14 is a portable generator designed to produce an ozone gas concentration below 1 ppm.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This Point of Attachment (POA) Air Control System connects to any breathing air source. It's housed in a Pelican carry case that can be wall mounted and includes an adjustable pressure regulator, pressure gauge and a pressure relief valve.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This heat stress meter features bright multi-color LCD backlights corresponding to OSHA's heat stress alert levels.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This unique sound meter enables remote sound level readings using a detachable probe. It features an RS232 computer interface, AC output and a coiled probe that extends to 9'.

' class='jquery-prod-cf-value' />
Aerotest Simultan Alpha for Measuring Grade D in Breathing Air

The quality of breathing air can be tested by this 4 gas detector in accordance to air purity standards according to ANSI specifications by means of quantitative measurements of the contaminants. Aerotest Simultan Alpha is suited for simultaneously examining the quality of air supplied by low pressure compressor or air supply lines. (50-300 psi)

Testing for CO, CO2, Oil and water content can be completed in as little as 5 minutes. The 4 gas detector can be connected to the low pressure compressed air supply systems via a barbed nipple connection. All components of the Aerotest Simultan Alpha are arranged in a carrying case and are ready to use.

Specifications

Medium Compressed air
Supply Pressure 50 psig to 300 psig
Connection Barbed nipple with ¼” NPT quick disconnect adapter
Flow 0.2 LPM & 4.0 LPM

Measuring Range

Tube
Measuring Range
Carbon Monoxide
5-50 ppm
Carbon Dioxide
100-3,000 ppm
Oil 0.1-10 mg/m3
Oil Impactor
0.1, 0.5, 1.0 mg/m3
Water Vapor
20-1,500 mg/m3

Ordering Information

Each Aerotest Simultan Alpha Kit, includes a deluxe carrying case, instructions, measuring device for tubes, quick-connect coupling and pressure reducer, deluxe tube opener, timer, oil impactor and impactor adapter and the tubes listed below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Aerotest Simultan Alpha Kit
6527150
Carbon Dioxide 100/a-P Tubes
6728521
Carbon Monoxide 5/a-P
6728511
Oil Impactor, pk/10 8103560
Oil 10/a-P 6728371
Water Vapor 20/a-P
8103061

Downloads

International Breathing Air Standards for Compressed A

Oil 10/a-P Tube Test Times datasheet

Oil Tube Detection limits datasheet

Dew point conversion table

Oil Tube Color Standard

Aerotest Simultan HP for High Pressure Grade D Air Testing

Aerotest Simultan HP is suited for examining the quality of air supplied by compressors or compressed air cylinders in the high pressure range. The quality of the breathing air can be tested in accordance to air purity standards (i.e. CGA Grade D or better or DIN 3188) according to ANSI specifications by means of quantitative measurements of the contaminants.

Measurements can be completed within 5 minutes.

The measuring device is provided with a DIN G 5/8″ connection. Adapters CGA 347 (male & female are provided for connection to US standard equipment. All components of the Aerotest Simultan are arranged in a transport case and ready for use.

Specifications

Medium Compressed air
Supply Pressure Maximum 4500 psi (200/300 bar)
Connection CGA 347 female connection to cylinder valve, CGA 347 male connection to compressor/filling station, G 5/8″ or INT
Flow 0.2 LPM & 4.0 LPM

Measuring Range

Tube Measuring Range
Carbon Monoxide
5-50 ppm
Carbon Dioxide
100-3,000 ppm
Oil
0.1, 0.5, 1.0 mg/m3
Water Vapor
20-1500 mg/m3

Ordering Information

The Aerotest Simultan HP Kit, includes a pressure reducer, measuring device for 4 tubes, timer, tube opener, CGA347 adapter, accuro pump, spare parts kit, instructions, case and 1 box of all tubes listed below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Aerotest Simultan HP Kit
6525990
Carbon Dioxide 100/a-P Tubes
6728521
Carbon Monoxide 5/a-P
6728511
Oil PN
8103111
Water Vapor 20/a-P
8103061

Downloads

International Breathing Air Standards for Compressed Air

Oil 10/a-P Tube Test Times datasheet

Oil Tube Detection limits datasheet

Dew point conversion table

Oil Tube Color Standard

Air Current Kit from Draeger Safety
The Draeger Air Current Kit is useful for the detection of air current to estimate their source, direction and speed. In some areas the detection of air current is of particular importance. Slight air currents must become visible to estimate their source, direction and speed. This is necessary
  • In mining for monitoring of firedamp in inaccessible places
  • In industry for the detection of leaks in pipelines, of air currents in rooms or for combustion plants and in laboratory stacks
  • In ventilation for control and setting up of air conditioning plants
In addition to this measurement, air currents are also helpful when estimating the distribution of toxic substances at workplaces. The knowledge of the air flow pattern permits objective selection of the right measuring points for any air analysis. The Draeger Air Current Kit consists of a porous carrier impregnated with fuming sulfuric acid. After opening the tube tips the air is pumped through the tube with the help of a rubber bulb. The white smoke emerging from the tube is carried along by the air flow and makes its direction visible. The air flow tester can be used repeatedly until smoke is finally exhausted. It the test is completed before the tube is exhausted, the tube should be sealed with the rubber caps provided.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
Air Current Kit includes carrying case, smoke tubes, tube opener, aspirator bulb, rubber caps, instructions & SDS sheet
CH00216
Smoke Tubes, pk/10
CH25301
Rubber Caps, pk/10 CH16631
Aspirator Bulb 4054382
Civil Defense Simultaneous Tube Kits

The Draeger CDS civil defense set utilizes colorimetric Draeger detector tubes, the same tube chemistry used by NATO for many years in single tube detectors. Are you prepared to respond to a terrorist attack involving chemical weapons? In today’s world, immediate and accurate detection of toxic chemical agents is crucial. Draeger has developed an important detection system not available from any other manufacturer – specialized sets that detect up to five different chemical agents simultaneously – in just 5 minutes.

The Draeger CDS Kit provides two CDS sets for detection of eight chemical substances, including nerve, blood, lung, nose and throat irritating agents. And, the complete CDS Kit is much less expensive than the typical $15,000 cost of spectroscopic devices.

Features/Benefits

  • Low cost compared to spectroscopic devices
  • No power supply required for manual pump
  • On the spot results in five minutes
  • No warm up time
  • No calibration
  • Minimal training
  • Simple operation
  • No filters to replace

Ordering Information, Single Sets

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Simultaneous Test CDS Set I includes Hydrocyanic Acid, Phosgene, Lewisite, N-Mustard & S-Mustard
8103140
Simultaneous Test CDS Set V includes Nerve Agent, Phosgene, Cyanogen Chloride, Chlorine, S-Mustard
8103200
CDS Training Set for Simultaneous Test Set I
8103230
CDS Training Set for Simultaneous Test Set V
8103240
Set Opener
6400095
CDS Laminated Matrix Card
4056371
Brief Instruction Flip Cards for CDS Set I 4057230
Brief Instruction Flip Cards for CDS Set V 4057231
Accuro Pump
6400000
Adapter with 1 M Extension Hose for Accuro Pump
6400561
Adapter with 1 M Extension Hose for X-Act 5000
6400561
Tube Warmer
8316130
Hot Packs for Tube Warmer
8316139

Ordering Information

Description
Catalog No.
CDS Kit for Domestic Preparedness, includes 5 each of CDS Set I, 5 each of CDS Set V, 2 each of Accuro Hand Pumps, 2 each of Simultest Extension Hoses, 2 each of Simultest Set Openers, Spare Parts Kit, Instructions and Case
4523130
CDS/HazMat Kit includes 3 each of CDS Set I, 3 each of CDS Set V, 3 Hazmat Simultest Set I, 3 each of HazMat Simultest II, 3 each of HazMat Simultest III, 2 Accuro Hand Pump, 2 each of Sumultest Set Extension Hoses, 2 each Simultest Set Openers, Spare Parts Kit, Instructions and Case
4000050
CDS Kit with X-Act 5000 includes 5 each of CDS Set I & V, Accuro Pump, 2 Extension Hoses for Simultaneous Test Sets, 2 Simultest Set Openers, Spare Parts Kit, X-act 5000 with NiMH Battery & Charger, X-act 5000 Alkaline Battery Pack, Instruction flip Card Set for Set I & V and Carrying Case  4000040
CDS/HazMat Kit with X-act 5000 includes 3 each of CDS Set I & V, Hazmat Simultest Test I, Set, II & Set III, Accuro Pump, Spare Parts Kit, 2 Extension Hoses, 2 Simultest Set Openers, X-act 5000 with NiMH Battery & Charger, X-act 5000 Alkaline Battery Pack, Instruction Flip Card for CDS Set I & V, Laminated Instruction Cards and Case  4000030

Downloads

Civil Defense literature
Technical information on the CDS kits

Clandestine Lab Investigation Kits from Draeger Safety

Various hazardous gases can be generated by clandestine drug manufacturing laboratories. The physiological effects of these gases can vary from mild irritation, choking, severe nausea or rendering investigating personnel unconscious. The Draeger Clandestine Lab Investigation Kit (CLIK) is a quick, simple and accurate method for detecting these toxic agents.

The Draeger Tube system consists of the hand held accuro sample pump that draws air through the glass detector tube. If the chemical agent is present, the Draeger Tube changes color. Higher concentrations of gas produce a longer length of color change. A graduated scale printed on the tube indicates gas concentrations.

The one handed operation of the accuro pump allows the other hand to be free for maneuvering into position or handling a weapon. The Draeger CLIK measure Ammonia, Phosphine and Hydrochloric Acid. Draeger tubes are available for measuring many other gases which be present in clandestine labs.

Ordering Information

The CLIK contains an accuro pump, tube opener, ammonia detector tubes, phosphine detector tubes, hydrochloric acid/nitric acid detector tubes, rigid carrying case, spare parts kit, allen wrench, and rubber caps. The Clan Lab Simultest Kit includes an accuro pump, simultest extension hose, simultest set opener, instructions, 5 Clan Lab Simultest Sets, instructions and case. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Clandestine Lab Investigation Kit
4520407
Clan Lab Simultest Kit
4056562

Accessory Ordering Information

Description
Catalog No.
3 Meter Extension Hose with Adapter
6400077
10 Meter Extension Hose with Adapter
6400078
15 Meter Extension Hose with Adapter
6400079
Ammonia Tubes
CH20501
Hydrochloric/Nitric Acid Tube
8101681
Phosphine Tubes
8103711
Clan Lab Simultest Set
8103310
Tube Warmer
8316130
Hot-Packs for Tube Warmer, pk/2 8316139
Molded Plastic Transport Case 4056442
Simultest Extension Hose for Accuro
6400561
Simultest Set Opener
6400095
Clan Lab Simultest Laminated Instruction Card
4056564

Downloads

Information about the Clan Lab Simultest Kit including instruments for use

HazMat Simultest Tube Kit from Draeger Safety

The Draeger HazMat Simultest Kit is based on the Simultaneous Tube Sets I, II & III. These sets are designed to detect gases evolved as the result of a structural fire and to determine organic chemical families. The HazMat Simultest does not require a complex, confusing matrix card used to determine what gases and vapors are present. Each test takes a total of one minute or less to conclude, therefore, the complete testing time for ten gases and five organic chemical families is less than five minutes.

The HazMat Simultest Kit includes the Accuro bellows pump, air current kit, 1 meter extension hose with adapter, 3 each of Simultaneous Test Sets I, 3 each of Simultaneous Test Set II & 4 each of Simultaneous Test Set III, Accuro spare parts kit, simultaneous test set opener and laminated instruction cards that have full color graphics making interpretation of the tubes quick and easy. A rugged Pelican carrying case protect the kit contents.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
HazMat Simultest Kit
4056098
HazMat Simultest Kit without Accuro Pump
4056447
Simultest Extension Hose, includes 1M hose, adapter & opener
6400561
Simultest Set Opener
6400095
Laminated Instruction Card for Set I & II
4056092
Laminated Instruction Card for Set III
4056091
Tube Warmer
8316130
Hazmat Simultest Training CD
4056561

Spare Tube Ordering Information

Description
Catalog No.
Simultaneous Test Set I, Inorganic fumes includes Acid Gases, e.g. Hydrochloric Acid, Basic Gases, e.g. Ammonia, Carbon Monoxide, Hydrocyanic Acid and Nitrous Gases, e.g. Nitrogen Dioxide
8101735
Simultaneous Test Set II, Inorganic fumes includes Phosphine, Chlorine, Hydrogen Sulfide, Phosgene and Sulfur Dioxide
8101736
Simultaneous Test Set III, Organic Vapors includes Alcohols, e.g. Methanol, Aliphatic Hydrocarbons, e.g. n-Hexane, Aromatics, e.g. Toluene, Chlorinated Hydrocarbons, e.g. Perchloroethylene and Ketones, e.g. Acetone
8101770

Downloads

Hazmat Simultest Kit Literature

HazMat Tube Kit from Draeger Safety

The HazMat Kit is designed to aid in the initial assessment of potentially hazardous situations. The detector tubes included in the kit have been selected to utilize a systematic sampling matrix. Using the Polytest Tube as a starting point, the sampling matrix provides a systematic test sequence to obtain information about the chemical group to which an unknown substance may belong. The HazMat Kit can also be used for providing quantitative measurement of specific gases and vapors.

Evaluation of test results can be performed on-site, without delay.

Housed in a durable, lightweight case, the HazMat Kit includes the Draeger Accuro Pump with an integrated stroke counter and end of stroke indicator, 3 meter extension hose for testing inaccessible areas and an Air Current Kit for determining wind direction and velocity. Other contents include spare parts for pump maintenance and 17 types of detector tubes. The components fit into a closed-cell foam insert which provides travel protection and organization.

Other sampling strategies may be more appropriate in certain situations, for instance when information on the identity by the chemicals is already known, For these applications the HazMat Kit is also available without detector tubes, enabling the user to customize the kit to address specific needs.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Hazmat Kit includes Accuro pump, spare parts kit for the pump, air current kit, tube handbook, tube opener, extension hose, rubber caps, screwdriver, carrying case and tubes listed below
4057185
Accuro Pump
6400000
Hazmat Kit without Tubes
4057184
Hazmat Kit without Tubes and Accuro Pump
4057183
Laminated Matrix Card
4054201

Spare Tube Ordering Information

Description
Catalog No.
Acetone 100/b, 100-12,000 ppm
Acid Test 8101121
Ammonia 0.25/a, 0.25-3 ppm
Carbon Dioxide 0.1%/a, 0.1-6 Vol %
Carbon Monoxide 10/b, 10-3,000 ppm
Chlorine 0.2/a, 0.2-30 ppm
DT Ethanol 100/a, 100-3,000 ppm
8103761
DT Nitrous Fumes 0.2/a, 0.2-30 ppm
8103661
Ethyl Acetate 200/a, 200-3,000 ppm
CH20201
Hydrocarbons 0.1%/c, 0.1-1.3 Vol % 8103571
Hydrocyanic Acid 0.5/a, 0.5-50 ppm
8103601
Hydrogen Sulfide 5/b, 5-600 ppm CH29801
Oxygen 5%/C, 5-23 Vol %
8103261
Perchloroethylene 2/a, 2-300 ppm
8101501
Polytest
Toluene 5/b, 5-300 ppm
8101661
Trichloroethylene 50/a, 50-500 ppm
8101881
Hot Pack Holder for Draeger Tubes
The Draeger Hot Pack Tube Warmer in connection with Hot Packs enables the use of Draeger Tubes below the temperature stated in the instructions. The first Tube Warmer without the need for electricity. All Draeger Tubes for short term measurements can be used until -20°C. By using the Hot Pack Holder with Draeger Tubes you are assured the accuracy of the Draeger Tubes as described in the instructions with the added value of temperature control. A solution of Potassium acetate becomes crystallized by a simple click of the starter and heats up immediately.

Features

  • Cost effective use onsite
  • No electrical power required
  • The Hot Packs can be reactivated up to several 100 times by boiling in water or in a microwave

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Hot Pack Holder, includes 2 Hot Packs
8316130
Hot Packs, pk/2
8316139

Downloads

Hot Pack Tube Warmer Datasheet
Simultaneous Tube Test Sets
The Simultaneous Tube Test Sets offer three different sets which are used with an adapter (purchased separately) and a Draeger Pump for the semi-quantitative determination of inorganic gases and organic vapors. Each test set is able to test for five different gases simultaneously in less than one minute. The sets provide on-site information to firefighters, Hazmat teams and environmental agencies. Please note: Draeger Tubes in the Simultaneous Test Sets are specifically calibrated to be used as a set. It is not recommended to mix tubes from any of the sets or use standard tubes with the Simultaneous Test Set Adapter.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Simultaneous Test Set I, Inorganic Fumes includes Acid Gases e.g. Hydrochloric Acid, Basic Gases e.g. Ammonia, Carbon Monoxide, Hydrocyanic Acid and Nitrous Gases eg. Nitrogen Dioxide
8101735
Simultaneous Test Set II, Inorganic fumes includes Phosphine, Chlorine, Hydrogen Sulfide, Phosgene, and Sulfur Dioxide
8101736
Simultaneous Test Set III, Organic Vapors includes Alcohols e.g. Methanol, Aliphatic Hydrocarbons, e.g. n-Hexane, Aromatics e.g. Toluene, Chlorinated Hydrocarbons e.g. Perchloroethylene and Ketones e.g. Acetone
8101770
Simultaneous Test Set for Clan Labs includes Phosphine, Phosgene, Ammonia, Hydrochloric Acid and Iodine
8103310
Simultaneous Test Set for Fumigation Services includes Ammonia, Methyl Bromide, Hydrogen Cyanide, Phosphine and Formaldehyde
8103410
Container Fumigation 1 Simultest Set, Pk/2 includes Formaldehyde, Phosphine, Hydrocyanic Acid, Methyl Bromide and Ethylene Oxide
8103380
Accuro Pump, required
6400000
Adapter, required
6400090

Downloads

Simultaneous Tube Test Sets Literature
Carbon Dioxide Injection Detection Kit
Gastec Injection Detection Kits are designed for testing high concentrations of propane and carbon dioxide gases. To use the kits, simply draw a sample into the provided syringe and insert a pre-calibrated detector tube. Measurement results are ready in moments. Gastec Injection Detection Kits are intrinsically safe and ready to use anytime, anywhere. Gastec’s detector tubes offer advanced technology, providing more accurate and reliable analysis with lower standard deviation. A direct-read scale printed on each tube means faster sampling time with no confusion, dual scales, or concentration charts. No extra equipment, lab analysis, or testing is necessary. To ensure the highest levels of quality, Gastec products are manufactured in ISO-9001 certified facilities. For easy tracking and quality assurance, an expiration date and lot number are printed on each tube.

Ordering Information

Each Kit contains a plastic syringe, metal tube tip breaker, box of carbon dioxide tubes (2HT), instructions, & carrying pouch.For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Carbon Dioxide Detection Kit 610
Replacement Carbon Dioxide Tubes, pk/10 2HT
 
Hazmat Detection Kit from Nextteq

This portable HazMat kit provides immediate identification of unknown chemicals and can detect contaminants competitors miss. This kit offers accurate detection of up to 48 gases and vapors. This kit features Gastec gas sampling pumps and detector tubes and are pre-calibrated and always ready to use. It is also intrinsically safe with no batteries or electrical power required. On the spot results save time and money with no waiting for expensive laboratory analysis. Gastec systems require fewer pump strokes and provide faster results than leading competitors. Direct read tubes expedite accurate sampling without confusion, dual scales or concentration charts. Decision charts provide clear, step by step instructions for easy and precise chemical analysis.

With lower detection limits this kit can detect trace levels of contaminants that competitors cannot. Additionally, Gastec’s higher maximum detection limits provide a more accurate measurement of contamination. The temperature range is 32 to 104ºF.

Gastec Detector tubes provide exact quantitative measurements. The pre-calibrated, direct-read detector tubes offer distinct lines of demarcation for easier viewing and require no interpretation dual scales or color charts.Many tubes require only 1 pump stroke, instead of up to 20.

Nextteq’s kits contain the first and only gas sampling pumps with direct read ambient temperature display. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of the Gastec Pump that accurately measures ambient temperature a 9ºF intervals from 32ºF to 104ºF. The Thermal Ring reduces the risk of error and increases safety enabling First Responders to correct for temperature variances on the spot. It is easy to use always ready and intrinsically safe.

A comprehensive decision charts is included with each kit and provides step by step directions to efficiently identify gases and vapors using the fewest detector tubes. The result from a single semi-quantitative, multi gas detector tube leads to a test(s) using individual quantitative detector tubes(s) for precise chemical analysis. Some competitors require the use of up to 15 qualitative tubes to identify the chemical present, increasing the time and cost of analysis.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Hazmat Kit includes Gastec pump with Thermal Ring, Detector Tube Handbook, Decision Chart I, Carrying Case, 5M Extension Hose, and tubes listed below
STD-100

Spare Tube Ordering Information

Description
Catalog No.
Ammonia 3L
Benzene 121S
Carbon Monoxide 1LA
Chlorine 8LA
Ethyl Acetate 141L
Hydrogen Cyanide 12L
Hydrogen Sulfide 4LL
Hydrocarbons, low class 103
Hydrocarbons, high class 105
Petroleum Naphtha 106
Polytec I 107
Stoddard Solvent 128
Sulfur Dioxide 5LB

Downloads

HazMat Kit Literature

Thermal Ring Literature

Deluxe Hazmat Detection Kit from Nextteq
This portable Deluxe HazMat Detection kit provides immediate identification of unknown chemicals and can detect contaminants competitors miss. This kit offers accurate detection of up to 48 gases and vapors and liquids. This kit features Gastec gas sampling pumps and detector tubes and are pre-calibrated and always ready to use. It is also intrinsically safe with no batteries or electrical power required. On the spot results save time and money with no waiting for expensive laboratory analysis. Gastec systems require fewer pump strokes and provide faster results than leading competitors. Direct read tubes expedite accurate sampling without confusion, dual scales or concentration charts. Decision charts provide clear, step by step instructions for easy and precise chemical analysis. The Deluxe HazMat Kit can identify more chemicals than a leading competitor. While some competitors can detect only 16 chemicals, the Deluxe Kit can precisely identify up to 48 gases, vapors and liquids. This kit is the only kit that can detect liquid chemical warfare agents. M8 Detection Paper provides immediate identification of toxic nerve agent (V and G) and blister agents (H). With lower detection limits this kit can detect trace levels of contaminants that competitors cannot. Additionally, Gastec’s higher maximum detection limits provide a more accurate measurement of contamination. The temperature range is 32 to 104ºF. Gastec Detector tubes provide exact quantitative measurements. The pre-calibrated, direct-read detector tubes offer distinct lines of demarcation for easier viewing and require no interpretation dual scales or color charts.Many tubes require only 1 pump stroke, instead of up to 20. Nextteq’s kits contain the first and only gas sampling pumps with direct read ambient temperature display. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of the Gastec Pump that accurately measures ambient temperature a 9ºF intervals from 32ºF to 104ºF. The Thermal Ring reduces the risk of error and increases safety enabling First Responders to correct for temperature variances on the spot. It is easy to use always ready and intrinsically safe. A comprehensive decision charts is included with each kit and provides step by step directions to efficiently identify gases and vapors using the fewest detector tubes. The result from a single semi-quantitative, multi gas detector tube leads to a test(s) using individual quantitative detector tubes(s) for precise chemical analysis. Some competitors require the use of up to 15 qualitative tubes to identify the chemical present, increasing the time and cost of analysis.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Deluxe Hazmat Kit includes Gastec pump with Thermal Ring, Detector Tube Handbook, Decision Chart I, Carrying Case, 5M Extension Hose, Irritant Smoke Kit, M8 Detection paper for nerve and blister agents, 2 Light Sticks, Tweezers and tubes listed below
STD-101
Deluxe HazMat Kit without Tubes, includes everything above but the detector tubes STD-101-1

Spare Tube Ordering Information

Description
Catalog No.
Ammonia 3L
Benzene 121S
Caron Monoxide 1LA
Chlorine 8LA
Ethyl Acetate 141L
Hydrogen Cyanide 12L
Hydrogen Sulfide 4LL
Hydrocarbons, low class 103
Hydrocarbons, high class 105
Petroleum Naphtha 106
Polytec I 107
Stoddard Solvent 128
Sulfur Dioxide 5LB

Downloads

HazMat Kit Literature Thermal Ring Literature Irritant Smoke Kit Literature M8 Detection Paper Literature
Smoke Tubes from Rae Systems
Smoke generation tubes from Rae Systems are designed for use in respirator fit tests or for visualizing air currents. These tubes made of the stannic chloride required by OSHA for irritant smoke fit test procedures. Users include hygienists for chemical plants, confined space entry, fire departments, paint sprayers, and sand blasters. Sealing the tube with rubber caps between applications means you can reuse the tubes until spent. These tubes can also be used for visualizing air currents, such as tracking air flows in mines, testing the performance of fume hoods, and detecting leaks from air ducts. Knowledge of air flow patterns is also useful for indoor air quality testing to establish optimum sampling points.Industries include mining, chemical plants for pipeline leak detection, and installers of air conditioning and ventilation systems.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Smoke Tube Kit
010-0004-000

Downloads

Rae Systems Smoke Tube Literature
Aerotest Simultan Alpha for Measuring Grade D in Breathing Air
The quality of breathing air can be tested by this 4 gas detector in accordance to air purity standards according to ANSI specifications by means of quantitative measurements of the contaminants. Aerotest Simultan Alpha is suited for simultaneously examining the quality of air supplied by low pressure compressor or air supply lines. (50-300 psi) Testing for CO, CO2, Oil and water content can be completed in as little as 5 minutes. The 4 gas detector can be connected to the low pressure compressed air supply systems via a barbed nipple connection. All components of the Aerotest Simultan Alpha are arranged in a carrying case and are ready to use. Specifications Medium Compressed air Supply Pressure 50 psig to 300 psig Connection Barbed nipple with ¼” NPT quick disconnect adapter Flow 0.2 LPM & 4.0 LPM Measuring Range Tube Measuring Range Carbon Monoxide 5-50 ppm Carbon Dioxide 100-3,000 ppm Oil 0.1-10 mg/m3 Oil Impactor 0.1, 0.5, 1.0 mg/m3 Water Vapor 20-1,500 mg/m3 Ordering Information Each Aerotest Simultan Alpha Kit, includes a deluxe carrying case, instructions, measuring device for tubes, quick-connect coupling and pressure reducer, deluxe tube opener, timer, oil impactor and impactor adapter and the tubes listed below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Aerotest Simultan Alpha Kit 6527150 Carbon Dioxide 100/a-P Tubes 6728521 Carbon Monoxide 5/a-P 6728511 Oil Impactor, pk/10 8103560 Oil 10/a-P 6728371 Water Vapor 20/a-P 8103061 Downloads International Breathing Air Standards for Compressed A Oil 10/a-P Tube Test Times datasheet Oil Tube Detection limits datasheet Dew point conversion table Oil Tube Color Standard
Manufacturer: Draeger Safety Inc
Brand: Aerotest
Model: Simultan Alpha
Short Description:

The quality of breathing air can be tested by this 4 gas detector in accordance to air purity standards according to ANSI specifications by means of quantitative measurements of the contaminants.

Aerotest Simultan HP for High Pressure Grade D Air Testing
Aerotest Simultan HP is suited for examining the quality of air supplied by compressors or compressed air cylinders in the high pressure range. The quality of the breathing air can be tested in accordance to air purity standards (i.e. CGA Grade D or better or DIN 3188) according to ANSI specifications by means of quantitative measurements of the contaminants. Measurements can be completed within 5 minutes. The measuring device is provided with a DIN G 5/8″ connection. Adapters CGA 347 (male & female are provided for connection to US standard equipment. All components of the Aerotest Simultan are arranged in a transport case and ready for use. Specifications Medium Compressed air Supply Pressure Maximum 4500 psi (200/300 bar) Connection CGA 347 female connection to cylinder valve, CGA 347 male connection to compressor/filling station, G 5/8″ or INT Flow 0.2 LPM & 4.0 LPM Measuring Range Tube Measuring Range Carbon Monoxide 5-50 ppm Carbon Dioxide 100-3,000 ppm Oil 0.1, 0.5, 1.0 mg/m3 Water Vapor 20-1500 mg/m3 Ordering Information The Aerotest Simultan HP Kit, includes a pressure reducer, measuring device for 4 tubes, timer, tube opener, CGA347 adapter, accuro pump, spare parts kit, instructions, case and 1 box of all tubes listed below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Aerotest Simultan HP Kit 6525990 Carbon Dioxide 100/a-P Tubes 6728521 Carbon Monoxide 5/a-P 6728511 Oil PN 8103111 Water Vapor 20/a-P 8103061 Downloads International Breathing Air Standards for Compressed Air Oil 10/a-P Tube Test Times datasheet Oil Tube Detection limits datasheet Dew point conversion table Oil Tube Color Standard
Manufacturer: Draeger Safety Inc
Brand: Aerotest
Model: Simultan HP
Short Description:

Aerotest Simultan HP +P is suited for examining the quality of air supplied by compressors or compressed air cylinders in the high pressure range.

Air Current Kit from Draeger Safety
The Draeger Air Current Kit is useful for the detection of air current to estimate their source, direction and speed. In some areas the detection of air current is of particular importance. Slight air currents must become visible to estimate their source, direction and speed. This is necessary In mining for monitoring of firedamp in inaccessible places In industry for the detection of leaks in pipelines, of air currents in rooms or for combustion plants and in laboratory stacks In ventilation for control and setting up of air conditioning plants In addition to this measurement, air currents are also helpful when estimating the distribution of toxic substances at workplaces. The knowledge of the air flow pattern permits objective selection of the right measuring points for any air analysis. The Draeger Air Current Kit consists of a porous carrier impregnated with fuming sulfuric acid. After opening the tube tips the air is pumped through the tube with the help of a rubber bulb. The white smoke emerging from the tube is carried along by the air flow and makes its direction visible. The air flow tester can be used repeatedly until smoke is finally exhausted. It the test is completed before the tube is exhausted, the tube should be sealed with the rubber caps provided. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com Description Catalog No. Air Current Kit includes carrying case, smoke tubes, tube opener, aspirator bulb, rubber caps, instructions & SDS sheet CH00216 Smoke Tubes, pk/10 CH25301 Rubber Caps, pk/10 CH16631 Aspirator Bulb 4054382
Manufacturer:
Brand:
Model:
Short Description:
Civil Defense Simultaneous Tube Kits
The Draeger CDS civil defense set utilizes colorimetric Draeger detector tubes, the same tube chemistry used by NATO for many years in single tube detectors. Are you prepared to respond to a terrorist attack involving chemical weapons? In today’s world, immediate and accurate detection of toxic chemical agents is crucial. Draeger has developed an important detection system not available from any other manufacturer – specialized sets that detect up to five different chemical agents simultaneously – in just 5 minutes. The Draeger CDS Kit provides two CDS sets for detection of eight chemical substances, including nerve, blood, lung, nose and throat irritating agents. And, the complete CDS Kit is much less expensive than the typical $15,000 cost of spectroscopic devices. Features/Benefits Low cost compared to spectroscopic devices No power supply required for manual pump On the spot results in five minutes No warm up time No calibration Minimal training Simple operation No filters to replace Ordering Information, Single Sets For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Simultaneous Test CDS Set I includes Hydrocyanic Acid, Phosgene, Lewisite, N-Mustard & S-Mustard 8103140 Simultaneous Test CDS Set V includes Nerve Agent, Phosgene, Cyanogen Chloride, Chlorine, S-Mustard 8103200 CDS Training Set for Simultaneous Test Set I 8103230 CDS Training Set for Simultaneous Test Set V 8103240 Set Opener 6400095 CDS Laminated Matrix Card 4056371 Brief Instruction Flip Cards for CDS Set I 4057230 Brief Instruction Flip Cards for CDS Set V 4057231 Accuro Pump 6400000 Adapter with 1 M Extension Hose for Accuro Pump 6400561 Adapter with 1 M Extension Hose for X-Act 5000 6400561 Tube Warmer 8316130 Hot Packs for Tube Warmer 8316139 Ordering Information Description Catalog No. CDS Kit for Domestic Preparedness, includes 5 each of CDS Set I, 5 each of CDS Set V, 2 each of Accuro Hand Pumps, 2 each of Simultest Extension Hoses, 2 each of Simultest Set Openers, Spare Parts Kit, Instructions and Case 4523130 CDS/HazMat Kit includes 3 each of CDS Set I, 3 each of CDS Set V, 3 Hazmat Simultest Set I, 3 each of HazMat Simultest II, 3 each of HazMat Simultest III, 2 Accuro Hand Pump, 2 each of Sumultest Set Extension Hoses, 2 each Simultest Set Openers, Spare Parts Kit, Instructions and Case 4000050 CDS Kit with X-Act 5000 includes 5 each of CDS Set I & V, Accuro Pump, 2 Extension Hoses for Simultaneous Test Sets, 2 Simultest Set Openers, Spare Parts Kit, X-act 5000 with NiMH Battery & Charger, X-act 5000 Alkaline Battery Pack, Instruction flip Card Set for Set I & V and Carrying Case  4000040 CDS/HazMat Kit with X-act 5000 includes 3 each of CDS Set I & V, Hazmat Simultest Test I, Set, II & Set III, Accuro Pump, Spare Parts Kit, 2 Extension Hoses, 2 Simultest Set Openers, X-act 5000 with NiMH Battery & Charger, X-act 5000 Alkaline Battery Pack, Instruction Flip Card for CDS Set I & V, Laminated Instruction Cards and Case  4000030 Downloads Civil Defense literature Technical information on the CDS kits
Manufacturer: Draeger Inc
Brand: Simultaneous Tube Kit
Model: Civil Defense
Short Description:

The Draeger CDS civil defense set utilizes colorimetric Draeger detector tubes, the same tube chemistry used by NATO for many years in single tube detectors.

Clandestine Lab Investigation Kits from Draeger Safety
Various hazardous gases can be generated by clandestine drug manufacturing laboratories. The physiological effects of these gases can vary from mild irritation, choking, severe nausea or rendering investigating personnel unconscious. The Draeger Clandestine Lab Investigation Kit (CLIK) is a quick, simple and accurate method for detecting these toxic agents. The Draeger Tube system consists of the hand held accuro sample pump that draws air through the glass detector tube. If the chemical agent is present, the Draeger Tube changes color. Higher concentrations of gas produce a longer length of color change. A graduated scale printed on the tube indicates gas concentrations. The one handed operation of the accuro pump allows the other hand to be free for maneuvering into position or handling a weapon. The Draeger CLIK measure Ammonia, Phosphine and Hydrochloric Acid. Draeger tubes are available for measuring many other gases which be present in clandestine labs. Ordering Information The CLIK contains an accuro pump, tube opener, ammonia detector tubes, phosphine detector tubes, hydrochloric acid/nitric acid detector tubes, rigid carrying case, spare parts kit, allen wrench, and rubber caps. The Clan Lab Simultest Kit includes an accuro pump, simultest extension hose, simultest set opener, instructions, 5 Clan Lab Simultest Sets, instructions and case. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Clandestine Lab Investigation Kit 4520407 Clan Lab Simultest Kit 4056562 Accessory Ordering Information Description Catalog No. 3 Meter Extension Hose with Adapter 6400077 10 Meter Extension Hose with Adapter 6400078 15 Meter Extension Hose with Adapter 6400079 Ammonia Tubes CH20501 Hydrochloric/Nitric Acid Tube 8101681 Phosphine Tubes 8103711 Clan Lab Simultest Set 8103310 Tube Warmer 8316130 Hot-Packs for Tube Warmer, pk/2 8316139 Molded Plastic Transport Case 4056442 Simultest Extension Hose for Accuro 6400561 Simultest Set Opener 6400095 Clan Lab Simultest Laminated Instruction Card 4056564 Downloads Information about the Clan Lab Simultest Kit including instruments for use
Manufacturer: Draeger Safety Inc
Brand: Colorimetric Tube Kit
Model: Clandestine Lab Kit
Short Description:

Various hazardous gases can be generated by clandestine drug manufacturing laboratories. The physiological effects of these gases can vary from mild irritation, choking, severe nausea or rendering investigating personnel unconscious.

HazMat Simultest Tube Kit from Draeger Safety
The Draeger HazMat Simultest Kit is based on the Simultaneous Tube Sets I, II & III. These sets are designed to detect gases evolved as the result of a structural fire and to determine organic chemical families. The HazMat Simultest does not require a complex, confusing matrix card used to determine what gases and vapors are present. Each test takes a total of one minute or less to conclude, therefore, the complete testing time for ten gases and five organic chemical families is less than five minutes. The HazMat Simultest Kit includes the Accuro bellows pump, air current kit, 1 meter extension hose with adapter, 3 each of Simultaneous Test Sets I, 3 each of Simultaneous Test Set II & 4 each of Simultaneous Test Set III, Accuro spare parts kit, simultaneous test set opener and laminated instruction cards that have full color graphics making interpretation of the tubes quick and easy. A rugged Pelican carrying case protect the kit contents. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. HazMat Simultest Kit 4056098 HazMat Simultest Kit without Accuro Pump 4056447 Simultest Extension Hose, includes 1M hose, adapter & opener 6400561 Simultest Set Opener 6400095 Laminated Instruction Card for Set I & II 4056092 Laminated Instruction Card for Set III 4056091 Tube Warmer 8316130 Hazmat Simultest Training CD 4056561 Spare Tube Ordering Information Description Catalog No. Simultaneous Test Set I, Inorganic fumes includes Acid Gases, e.g. Hydrochloric Acid, Basic Gases, e.g. Ammonia, Carbon Monoxide, Hydrocyanic Acid and Nitrous Gases, e.g. Nitrogen Dioxide 8101735 Simultaneous Test Set II, Inorganic fumes includes Phosphine, Chlorine, Hydrogen Sulfide, Phosgene and Sulfur Dioxide 8101736 Simultaneous Test Set III, Organic Vapors includes Alcohols, e.g. Methanol, Aliphatic Hydrocarbons, e.g. n-Hexane, Aromatics, e.g. Toluene, Chlorinated Hydrocarbons, e.g. Perchloroethylene and Ketones, e.g. Acetone 8101770 Downloads Hazmat Simultest Kit Literature
Manufacturer: Draeger Safety Inc
Brand: Simultest Tube Kit
Model: HazMat
Short Description:

The Draeger HazMat Simultest Kit is based on the Simultaneous Tube Sets I, II & III. These sets are designed to detect gases evolved as the result of a structural fire and to determine organic chemical families.

HazMat Tube Kit from Draeger Safety
The HazMat Kit is designed to aid in the initial assessment of potentially hazardous situations. The detector tubes included in the kit have been selected to utilize a systematic sampling matrix. Using the Polytest Tube as a starting point, the sampling matrix provides a systematic test sequence to obtain information about the chemical group to which an unknown substance may belong. The HazMat Kit can also be used for providing quantitative measurement of specific gases and vapors. Evaluation of test results can be performed on-site, without delay. Housed in a durable, lightweight case, the HazMat Kit includes the Draeger Accuro Pump with an integrated stroke counter and end of stroke indicator, 3 meter extension hose for testing inaccessible areas and an Air Current Kit for determining wind direction and velocity. Other contents include spare parts for pump maintenance and 17 types of detector tubes. The components fit into a closed-cell foam insert which provides travel protection and organization. Other sampling strategies may be more appropriate in certain situations, for instance when information on the identity by the chemicals is already known, For these applications the HazMat Kit is also available without detector tubes, enabling the user to customize the kit to address specific needs. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Hazmat Kit includes Accuro pump, spare parts kit for the pump, air current kit, tube handbook, tube opener, extension hose, rubber caps, screwdriver, carrying case and tubes listed below 4057185 Accuro Pump 6400000 Hazmat Kit without Tubes 4057184 Hazmat Kit without Tubes and Accuro Pump 4057183 Laminated Matrix Card 4054201 Spare Tube Ordering Information Description Catalog No. Acetone 100/b, 100-12,000 ppm CH22901 Acid Test 8101121 Ammonia 0.25/a, 0.25-3 ppm 8101711 Carbon Dioxide 0.1%/a, 0.1-6 Vol % CH23501 Carbon Monoxide 10/b, 10-3,000 ppm CH20601 Chlorine 0.2/a, 0.2-30 ppm CH24301 DT Ethanol 100/a, 100-3,000 ppm 8103761 DT Nitrous Fumes 0.2/a, 0.2-30 ppm 8103661 Ethyl Acetate 200/a, 200-3,000 ppm CH20201 Hydrocarbons 0.1%/c, 0.1-1.3 Vol % 8103571 Hydrocyanic Acid 0.5/a, 0.5-50 ppm 8103601 Hydrogen Sulfide 5/b, 5-600 ppm CH29801 Oxygen 5%/C, 5-23 Vol % 8103261 Perchloroethylene 2/a, 2-300 ppm 8101501 Polytest CH28401 Toluene 5/b, 5-300 ppm 8101661 Trichloroethylene 50/a, 50-500 ppm 8101881
Manufacturer: Draeger Safety Inc
Brand: Colorimetric Tube Kit
Model: HazMat Kit
Short Description:

The HazMat Kit is designed to aid in the initial assessment of potentially hazardous situations. The detector tubes included in the kit have been selected to utilize a systematic sampling matrix.

Hot Pack Holder for Draeger Tubes
The Draeger Hot Pack Tube Warmer in connection with Hot Packs enables the use of Draeger Tubes below the temperature stated in the instructions. The first Tube Warmer without the need for electricity. All Draeger Tubes for short term measurements can be used until -20°C. By using the Hot Pack Holder with Draeger Tubes you are assured the accuracy of the Draeger Tubes as described in the instructions with the added value of temperature control. A solution of Potassium acetate becomes crystallized by a simple click of the starter and heats up immediately. Features Cost effective use onsite No electrical power required The Hot Packs can be reactivated up to several 100 times by boiling in water or in a microwave Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Hot Pack Holder, includes 2 Hot Packs 8316130 Hot Packs, pk/2 8316139 Downloads Hot Pack Tube Warmer Datasheet
Manufacturer:
Brand:
Model:
Short Description:
Simultaneous Tube Test Sets
The Simultaneous Tube Test Sets offer three different sets which are used with an adapter (purchased separately) and a Draeger Pump for the semi-quantitative determination of inorganic gases and organic vapors. Each test set is able to test for five different gases simultaneously in less than one minute. The sets provide on-site information to firefighters, Hazmat teams and environmental agencies. Please note: Draeger Tubes in the Simultaneous Test Sets are specifically calibrated to be used as a set. It is not recommended to mix tubes from any of the sets or use standard tubes with the Simultaneous Test Set Adapter. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Simultaneous Test Set I, Inorganic Fumes includes Acid Gases e.g. Hydrochloric Acid, Basic Gases e.g. Ammonia, Carbon Monoxide, Hydrocyanic Acid and Nitrous Gases eg. Nitrogen Dioxide 8101735 Simultaneous Test Set II, Inorganic fumes includes Phosphine, Chlorine, Hydrogen Sulfide, Phosgene, and Sulfur Dioxide 8101736 Simultaneous Test Set III, Organic Vapors includes Alcohols e.g. Methanol, Aliphatic Hydrocarbons, e.g. n-Hexane, Aromatics e.g. Toluene, Chlorinated Hydrocarbons e.g. Perchloroethylene and Ketones e.g. Acetone 8101770 Simultaneous Test Set for Clan Labs includes Phosphine, Phosgene, Ammonia, Hydrochloric Acid and Iodine 8103310 Simultaneous Test Set for Fumigation Services includes Ammonia, Methyl Bromide, Hydrogen Cyanide, Phosphine and Formaldehyde 8103410 Container Fumigation 1 Simultest Set, Pk/2 includes Formaldehyde, Phosphine, Hydrocyanic Acid, Methyl Bromide and Ethylene Oxide 8103380 Accuro Pump, required 6400000 Adapter, required 6400090 Downloads Simultaneous Tube Test Sets Literature
Manufacturer:
Brand:
Model:
Short Description:
Carbon Dioxide Injection Detection Kit
Gastec Injection Detection Kits are designed for testing high concentrations of propane and carbon dioxide gases. To use the kits, simply draw a sample into the provided syringe and insert a pre-calibrated detector tube. Measurement results are ready in moments. Gastec Injection Detection Kits are intrinsically safe and ready to use anytime, anywhere. Gastec’s detector tubes offer advanced technology, providing more accurate and reliable analysis with lower standard deviation. A direct-read scale printed on each tube means faster sampling time with no confusion, dual scales, or concentration charts. No extra equipment, lab analysis, or testing is necessary. To ensure the highest levels of quality, Gastec products are manufactured in ISO-9001 certified facilities. For easy tracking and quality assurance, an expiration date and lot number are printed on each tube. Ordering Information Each Kit contains a plastic syringe, metal tube tip breaker, box of carbon dioxide tubes (2HT), instructions, & carrying pouch.For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Carbon Dioxide Detection Kit 610 Replacement Carbon Dioxide Tubes, pk/10 2HT  
Manufacturer:
Brand:
Model:
Short Description:
Hazmat Detection Kit from Nextteq
This portable HazMat kit provides immediate identification of unknown chemicals and can detect contaminants competitors miss. This kit offers accurate detection of up to 48 gases and vapors. This kit features Gastec gas sampling pumps and detector tubes and are pre-calibrated and always ready to use. It is also intrinsically safe with no batteries or electrical power required. On the spot results save time and money with no waiting for expensive laboratory analysis. Gastec systems require fewer pump strokes and provide faster results than leading competitors. Direct read tubes expedite accurate sampling without confusion, dual scales or concentration charts. Decision charts provide clear, step by step instructions for easy and precise chemical analysis. With lower detection limits this kit can detect trace levels of contaminants that competitors cannot. Additionally, Gastec’s higher maximum detection limits provide a more accurate measurement of contamination. The temperature range is 32 to 104ºF. Gastec Detector tubes provide exact quantitative measurements. The pre-calibrated, direct-read detector tubes offer distinct lines of demarcation for easier viewing and require no interpretation dual scales or color charts.Many tubes require only 1 pump stroke, instead of up to 20. Nextteq’s kits contain the first and only gas sampling pumps with direct read ambient temperature display. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of the Gastec Pump that accurately measures ambient temperature a 9ºF intervals from 32ºF to 104ºF. The Thermal Ring reduces the risk of error and increases safety enabling First Responders to correct for temperature variances on the spot. It is easy to use always ready and intrinsically safe. A comprehensive decision charts is included with each kit and provides step by step directions to efficiently identify gases and vapors using the fewest detector tubes. The result from a single semi-quantitative, multi gas detector tube leads to a test(s) using individual quantitative detector tubes(s) for precise chemical analysis. Some competitors require the use of up to 15 qualitative tubes to identify the chemical present, increasing the time and cost of analysis. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Hazmat Kit includes Gastec pump with Thermal Ring, Detector Tube Handbook, Decision Chart I, Carrying Case, 5M Extension Hose, and tubes listed below STD-100 Spare Tube Ordering Information Description Catalog No. Ammonia 3L Benzene 121S Carbon Monoxide 1LA Chlorine 8LA Ethyl Acetate 141L Hydrogen Cyanide 12L Hydrogen Sulfide 4LL Hydrocarbons, low class 103 Hydrocarbons, high class 105 Petroleum Naphtha 106 Polytec I 107 Stoddard Solvent 128 Sulfur Dioxide 5LB Downloads HazMat Kit Literature Thermal Ring Literature
Manufacturer: Nextteq LLC
Brand: Hazmat Kit
Model: Standard
Short Description:

This portable HazMat kit provides immediate identification of unknown chemicals and can detect contaminants competitors miss. This kit offers accurate detection of up to 48 gases and vapors.

Deluxe Hazmat Detection Kit from Nextteq
This portable Deluxe HazMat Detection kit provides immediate identification of unknown chemicals and can detect contaminants competitors miss. This kit offers accurate detection of up to 48 gases and vapors and liquids. This kit features Gastec gas sampling pumps and detector tubes and are pre-calibrated and always ready to use. It is also intrinsically safe with no batteries or electrical power required. On the spot results save time and money with no waiting for expensive laboratory analysis. Gastec systems require fewer pump strokes and provide faster results than leading competitors. Direct read tubes expedite accurate sampling without confusion, dual scales or concentration charts. Decision charts provide clear, step by step instructions for easy and precise chemical analysis. The Deluxe HazMat Kit can identify more chemicals than a leading competitor. While some competitors can detect only 16 chemicals, the Deluxe Kit can precisely identify up to 48 gases, vapors and liquids. This kit is the only kit that can detect liquid chemical warfare agents. M8 Detection Paper provides immediate identification of toxic nerve agent (V and G) and blister agents (H). With lower detection limits this kit can detect trace levels of contaminants that competitors cannot. Additionally, Gastec’s higher maximum detection limits provide a more accurate measurement of contamination. The temperature range is 32 to 104ºF. Gastec Detector tubes provide exact quantitative measurements. The pre-calibrated, direct-read detector tubes offer distinct lines of demarcation for easier viewing and require no interpretation dual scales or color charts.Many tubes require only 1 pump stroke, instead of up to 20. Nextteq’s kits contain the first and only gas sampling pumps with direct read ambient temperature display. Nextteq’s patented Thermal Ring is a paper-thin innovation encircling the base of the Gastec Pump that accurately measures ambient temperature a 9ºF intervals from 32ºF to 104ºF. The Thermal Ring reduces the risk of error and increases safety enabling First Responders to correct for temperature variances on the spot. It is easy to use always ready and intrinsically safe. A comprehensive decision charts is included with each kit and provides step by step directions to efficiently identify gases and vapors using the fewest detector tubes. The result from a single semi-quantitative, multi gas detector tube leads to a test(s) using individual quantitative detector tubes(s) for precise chemical analysis. Some competitors require the use of up to 15 qualitative tubes to identify the chemical present, increasing the time and cost of analysis. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Deluxe Hazmat Kit includes Gastec pump with Thermal Ring, Detector Tube Handbook, Decision Chart I, Carrying Case, 5M Extension Hose, Irritant Smoke Kit, M8 Detection paper for nerve and blister agents, 2 Light Sticks, Tweezers and tubes listed below STD-101 Deluxe HazMat Kit without Tubes, includes everything above but the detector tubes STD-101-1 Spare Tube Ordering Information Description Catalog No. Ammonia 3L Benzene 121S Caron Monoxide 1LA Chlorine 8LA Ethyl Acetate 141L Hydrogen Cyanide 12L Hydrogen Sulfide 4LL Hydrocarbons, low class 103 Hydrocarbons, high class 105 Petroleum Naphtha 106 Polytec I 107 Stoddard Solvent 128 Sulfur Dioxide 5LB Downloads HazMat Kit Literature Thermal Ring Literature Irritant Smoke Kit Literature M8 Detection Paper Literature
Manufacturer:
Brand:
Model:
Short Description:
Smoke Tubes from Rae Systems
Smoke generation tubes from Rae Systems are designed for use in respirator fit tests or for visualizing air currents. These tubes made of the stannic chloride required by OSHA for irritant smoke fit test procedures. Users include hygienists for chemical plants, confined space entry, fire departments, paint sprayers, and sand blasters. Sealing the tube with rubber caps between applications means you can reuse the tubes until spent. These tubes can also be used for visualizing air currents, such as tracking air flows in mines, testing the performance of fume hoods, and detecting leaks from air ducts. Knowledge of air flow patterns is also useful for indoor air quality testing to establish optimum sampling points.Industries include mining, chemical plants for pipeline leak detection, and installers of air conditioning and ventilation systems. Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. Smoke Tube Kit 010-0004-000 Downloads Rae Systems Smoke Tube Literature
Manufacturer:
Brand:
Model:
Short Description: