Description
Description
The RAM 744 Wall Mount Grade D Breathing Air System is the ideal monitor for wall mount applications and where space is limited. It is mounted with the filtration system, allowing for rapid response and eliminating the possibility of sample lines becoming blocked or crimped. The flow rate is fixed so there are no touchy flow meters to adjust.
The RAM 744 monitor is designed to satisfy OSHA monitoring requirements for Grade D breathing air. Utilizing an electrochemical sensor, the monitor alerts the user to excessive carbon monoxide levels that enter the airline system. Operating from a 110V AC or 9 V battery power source, this unit is able to activate optional devices like an air horn that is safe in explosive environments such as paint booths. A simple calibration system, alarm contacts and compact size make the RAM 744 ideal for many applications. The design of the RAM 744 requires mounting with a GfG 25, 50 or 100 CFM airline filter system.
Calibration and maintenance are made simple with the innovative AutoCal system that allows the CO sensor to be calibrated with the flip of a switch and test gas connection. The alarm level is set to 10 ppm.
The compact portable air case encloses the three stage 25, 50 or 100 CFM filter panel with the RAM 744 CO monitor. All models have quick connect inlets and outlets.
The RAM 744 satisfies the requirements of OSHA rule 29 CFM 1910.134 (d) (2) (ii) for carbon monoxide monitoring. They will also monitor Grade E air which is generally specified for breathing air in cylinders (SCBA).