PortaSens III Gas Leak Detector from Analytical Technology

The ATI PortaSens II has been updated to the PortaSens III portable gas leak detector. The new PortaSens III is a rugged hand held device used to detect leaks of toxic or otherwise dangerous gas and also to detect oxygen displacement.

The D16 quickly adapts to measure different gases by inserting the appropriate gas sensor module which retains all of the calibration and configuration settings for the target gas. An internal pump with a flexible wand is included for point sampling around suspect pipe fittings and confined spaces.

Readings and settings are presented on a backlighted, resistive touch, color graphics LCD with a beeper to notify you of alarms and other events. Readings are recorded in .csv files (ASCII text, comma-separated values) and transferred to a PC using the supplied USB cable. No external application is required. The files may be opened with any text editor or directly by applications like Microsoft Excel.

Power is provided from a rechargeable NiMH D-cell battery. The battery should be removed and charged in an external charger after each use. The battery is not used or even required when the device is connected to a USB port.

The inlet port, located on the manifold lid, is fitted with a quick disconnect fitting to connect the flexible want. The wand can be used for probing closely around pipes and fittings and for sampled confined spaces without entering. The wand is lined with Teflon and is inert to nearly all vapors and gases.

Flexible tubing may be connected to the inlet port to sample high gas concentration or those beyond the reach of the wand. Fluorocarbon based tubing is strongly recommended for measuring low concentrations of reactive gases. Other materials may be used for high range measurements where the adsorption of gas by the tubing is negligible or where you are probing or significant leaks.

The internal walls of the wand and any inlet tubing must be kept dry. Water on the walls may absorb soluble gases and decrease the gas readings, presenting an unsafe condition. If the inside of the wand or tubing gets wet, dry dry air through it for 10-15 minutes.

Features

  • Interchangeable smart sensors for over 30 gases
  • Internal sample pump and external sampling wand
  • One hand pistol grip design
  • Easy to read back lit color graphics, LCD
  • Instantaneous and timed sampling modes of operation
  • Visual and audible alarms
  • Internal datalogger with RS-232 output

Specifications

Range Dependent on gas, see chart below
Display Backlighted, resistive touch sensitive 320 x 240 color graphics LCD with an anti-glare overlay.
Accuracy ±5% of value, sensor dependent
Sensitivity 1% of sensor module range
Repeatability ±1% of lowest sensor module range
Sampling Pump Internal diaphragm pump, 400cc/min, adjustable, long life, variable speed, DC motor
Alarms Three level alarms, configurable for high or low operation or disabled
Trouble, low battery, restricted flow alarms
Alarm indications on LCD and beeper
Data Logger Internal 4Gb, selectable sampling intervals from 10 seconds to 60 minutes
Sample/Measure Self timed sample/measure mode for repeatable readings
Real Time Clock Battery backed, accurate to about 1 minute per year
Input/Output USB 2.0 MDS Class interface with 1 m mini-USB cable
Power D-cell battery, rechargeable, NiMH, external charger required
10-12 hours of continuous use
Alkaline D-Cell battery
USB connection provides power, but does not charge battery
Operating Temperature -25° to 55°C
Size 3.5″ W x 9″ H x 5.5″ D
Weight 7 pounds

Ordering Information

The PortaSens III is supplied in a padded carrying case for easy storage and transport. Space is provided for an extra battery plus up to two sensor keepers, which means up to 8 extra sensors ready for immediate use. Each PortaSens III includes the detector, spare filters, 10″ Teflon lined sampling wand, flowmeter, USB cable, spare NIMH “D” cell battery, sensor keeper and calibration”T” fitting. The basic PortaSens III detector does not include sensor modules. Because the PortaSens III is designed to accept any gas sensor, you can select one or more sensor modules. Each sensor module is factory calibrated for the minimum and maximum ranges indicated. The standard factory calibration for the module is listed below. Please choose the sensor below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
Model C16-1 PortaSens III, 120 VAC Charger
00-1876
Charger 28-0039

Sensor Specifications & Ordering Information

Gas
Range
Resolution
Factory Calibration
Part No.
Acetic Acid
0-100/500 ppm
100 ppm
00-1045
Acid Gases
0-10/200 ppm
0.1 ppm
20 ppm
00-1038
Acetylene
0-200/2,000 ppm
1 ppm
500 ppm
00-1057
Alcohol
0-50/500 ppm
1 ppm
200 ppm
00-1043
0-500/2,000 ppm
1 ppm
2,000 ppm
00-1044
Ammonia
0-50/500 ppm
1 ppm
200 ppm
00-1010
0-500/2,000 ppm
1 ppm
1,000 ppm
00-1011
Arsine
0-500/2,000 ppb
1 ppb
1,000 ppb
00-1024
0-10/200 ppm
0.1 ppm
10 ppm
00-1025
Bromine
0-1/5 ppm
0.01 ppm
2 ppm
00-1000
0-5/100
0.1 ppm
20 ppm
00-1001
Carbon Dioxide-IR
0-0.2/1.5% ppm
1 ppm
200 ppm
00-1012
Carbon Monoxide
0-50/1,000 ppm
1 ppm
200 ppm
00-1012
Chlorine
0-1/5 ppm
0.01 ppm
2 ppm
00-1002
0-5/100 ppm
0.1 ppm
20 ppm
00-1003
Chlorine Dioxide
0-1/5 ppm
0.01 ppm
2 ppm
00-1004
0-1/5 ppm
Low Cl2 Response
00-1425
0-5/200 ppm
0.1 ppm
20 ppm
00-1005
0-200/1,000 ppm
0.1 ppm
1,000 ppm
00-1359
Diborane
0-500/2,000 ppb
1 ppb
1,000 ppb
00-1026
0-10/200 ppm
0.1 ppm
10 ppm
00-1027
Dimethyl-amine (DMA)
0-100/200 ppm
100 ppm
00-1450
Ethylene Oxide
0-20/200 ppm
0.1 ppm
20 ppm
00-1039
Fluorine
0-1/5 ppm
0.01 ppm
2 ppm
00-1006
0-5/100 ppm
0.1 ppm
20 ppm
00-1007
Formaldehyde
0-20/200 ppm
0.1 ppm
20 ppm
00-1040
0-500/2,000 ppm
1 ppm
1,000 ppm
00-1349
Germane
0-500/2,000 ppb
1 ppb
1,000 ppb
00-1028
0-10/200 ppm
0.1 ppm
10 ppm
00-1029
Hydrogen
0-1/10%
0.01%
4%
00-1013
0-500/2,000 ppm
1 ppm
2,000 ppm
00-1041
Hydrogen Bromide
0-10/200 ppm
20 ppm
00-1455
Hydrogen Chloride
0-10/200 ppm
0.1 ppm
20 ppm
00-1017
Hydrogen Cyanide
0-10/200 ppm
0.1 ppm
20 ppm
00-1018
Hydrogen Fluoride
0-10/200 ppm
0.1 ppm
20 ppm
00-1019
Hydrogen Peroxide
0-200/2,000 ppm
0.1 ppm
1,000 ppm
00-1169
0-10/100 ppm
0.1 ppm
20 ppm
00-1042
Hydrogen Selenide
0-500/2,000 ppb
1 ppb
1,000 ppb
00-1030
0-10/200 ppm
0.1 ppm
10 ppm
00-1031
Hydrogen Sulfide
0-10/200 ppm
0.1 ppm
50 ppm
00-1020
0-200/1,000 ppm
500 ppm
00-1469
Iodine
0-1/5 ppm
0.01 ppm
2 ppm
00-1036
0-5/100 ppm
0.1 ppm
20 ppm
00-1037
Nitrogen Dioxide
0-10/200 ppm
0.1 ppm
20 ppm
00-1022
Nitric Oxide
0-50/500 ppm
1 ppm
200 ppm
00-1021
NOX
0-50/500 ppm
0.1 ppm
200 ppm
00-1181
Oxygen
0-5/25%
0.1%
25%
00-1014
Ozone
0-1/5 ppm
0.01 ppm
2 ppm
00-1008
0-500/2,000 ppb
1,000 ppb
00-1163
0-5/200 ppm
0.1 ppm
20 ppm
00-1009
0-200/1,000 ppm
0.1 ppm
1,000 ppm
00-1358
Phosgene
0-1/5 ppm
0.01 ppm
2 ppm
00-1015
0-5/100 ppm
0.1 ppm
100 ppm
00-1016
Phosphine
0-500/2,000 ppb
1 ppb
1,000 ppb
00-1032
0-10/200 ppm
0.1 ppm
10 ppm
00-1033
0-200/2,000 ppm
1 ppm
1,000 ppm
00-1034
Silane
0-10/200 ppm
0.1 ppm
10 ppm
00-1035
Sulfur Dioxide
0-10/500 ppm
0.1 ppm
20 ppm
00-1023
Combustible IR
0-20/100%
00-1883