The mSquad Wireless Detection System is a quickly deployable set of mobile multi gas meters that communicate wirelessly to a Squad Leader up to 0.5 miles away. The system is ideal for Hazmat Response, fire fighters, temporary venue protection, etc. An mSquad consists of one Head monitors (MP400H) and up to 8 Soldier monitors (MP400S) that communicate with each other. Each 4 or 5 gas monitors has options for a full range of sensors for toxic gases, oxygen, combustible and carbon dioxide. The MP400S can also have a PI for volatile organic compounds (VOCs). In addition to high gas concentration alarms, all Squad units receive any Man-Down alarms to notify them remotely of a worker in distress. All the Squad monitors are Class I, Division I certified to operate in hazardous zones. The entire mSquad is mobile, running on batteries for up to 12 hours. The MP400S and MP400H have rugged construction and easy to learn 2 button operation.

Features

  • Remote, wireless real-time readings and alarms including Man-Down
  • Up to 8 remote 4- or 5-gas monitors
  • Up to 0.5 miles distance to Squad head
  • All mSquad units alarm if any one unit has an alarm condition
  • Mobile system operation
  • 12 hour continuous operation on single Li-ion battery charge
  • USB micro cable for battery chageing and direct PC communication
  • Wide selection of sensor types

Specifications

Detector Electrochemical for Toxic gases and Oxygen
Pellistor: Combustible
PID: Volatile organic compounds
NDIR: LEL, VOL% and carbon dioxide
Battery Rechargeable Lithium-ion
Operating Periods 8-36 hour depending on configuration
Graphic Display 128 x 128 graphical LCD, 1.77 x 1.73″
LED backlight for enhanced display
Wireless Alarm Notification Alarm on any monitor sent to all other in mSquad for 5 seconds, then remains on at MP400H
Direct Readout Real time reading of gas concentrations
PID measurement of gas and correction factor
Battery status
STEL, TWA, peak and minimum values
Man-Down alarm on/off
Alarm Audible: 95 dB @ 30 cm
Visual: Flashing bright red LEDs
Vibration
On-screen indication of alarm conditions
Man-Down alarm
EMI/RFI EMC directive: 2004/30/EC
IP Rating Pump: IP-65
Diffusion: IP-67
Range 0.5 miles between MP400H and MP400S
Frequency ISM band (902-928 MHz) FCC Part 15 approved
Data Logging Continuous datalogging, 6 months for 4 sensors at 1 minute intervals, 24 hours/day and 7 days/week
Communication & Charging USB cable for charging, data download, instrument setup and firmware upgrades on PC or 100-240V AC charger, or CaliCase
Sampling Built in pump or diffusion
Calibration Zero and span calibration, single or multiple sensor simultaneous calibration settings
Temperature -4° to 122°F
Humidity 0-95% rH, non-condensing
Size 5.7″ x 3.3″ x 1.7″
Weight 15.5 ounces
Approvals Class I, Div 1, Groups A, B, C, D

Sensor Specifications

Gas
Range
Resolution
Combustible Gas (LEL%)
0-100% LEL
1%
Oxygen
0.1-30%
0.1%
Carbon Monoxide
0-1,000 ppm
1 ppm
0-1,000 ppm, Low H2
1 ppm
Hydrogen Sulfide
0-100 ppm
0.1 ppm
0-1,000 ppm
1 ppm
PID
0.1-2,000 ppm
0.1 ppm
Hydrocarbons NDIR (Vol%)
0-100% Vol
0.1% Vol
0-5% Vol, 1-200% LEL
0.1% Vol
Carbon Dioxide
50-50,000 ppm
100 ppm
Carbon Monoxide/Hydrogen Sulfide
CO: 1-500 ppm
H2S: 0.1-200 ppm
CO: 1 ppm
H2S 0.1 ppm
Sulfur Dioxide/Hydrogen Sulfide
SO2: 0.1-20 ppm
H2S: 0.1-100 ppm
SO2: 0.1 ppm
H2S: 0.1 ppm
Ammonia
0-100 ppm
1 ppm
0-500 ppm
1 ppm
Chlorine
0.1-50 ppm
0.1 ppm
Chlorine Dioxide
0.01-1 ppm
0.01 ppm
Hydrogen
0-1,000 ppm
1 ppm
Hydrogen Chloride
0.1-15 ppm
0.1 ppm
Hydrogen Fluoride
0.1-20 ppm
0.1 ppm
Hydrogen Cyanide
1-100 ppm
1 ppm
Nitric Oxide
0-250 ppm
1 ppm
Nitrogen Dioxide
0.1-20 ppm
0.1 ppm
Phosphine
0.01-20 ppm
0.01 ppm
Sulfur Dioxide
0.1-20 ppm
0.1 ppm
0.1-100 ppm
0.1 ppm
Acetaldehyde
1-20 ppm
0.1 ppm
Methyl Mercaptan
0.1-10 ppm
0.1 ppm
Ethylene Oxide
1-100 ppm
0.1 ppm

Ordering Information

The mSquad Wireless Detection System Kits include monitors, hard case with foam, charger with 4 USB ports, 4 USB cables, calibration cup (for Head), 2 calibration adapters (for Soldiers), water trap filters and quick start guide. Many other configurations available, call for details. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
mSquad 4 includes 1 head & 3 soldiers in case, 4 gas monitors with LEL/O2/H2S/CO sensors M004-0031-000
mSquad 4 includes 1 head & 3 soldiers in case, 4 gas monitors with LEL/O2/HCN/CO sensors M004-0032-000
mSquad 4 includes 1 head & 3 soldiers in case, 5 gas monitors with PID/LEL/O2/H2S/CO sensors M004-0033-000
mSquad 8 includes 1 head & 7 soldiers in case, 4 gas monitors with LEL/O2/H2S/CO sensors M004-0035-000
mSquad 4 includes 1 head & 7 soldiers in case, 4 gas monitors with LEL/O2/HCN/CO sensors M004-0036-000
mSquad 4 includes 1 head & 7 soldiers in case, 5 gas monitors with PID/LEL/O2/HCN/CO sensors M004-0037-000
Solider MP400S 5 Gas Detector with PID/LEL/O2/CO/H2S Sensors MPAS-21A1A6-010M0
Solider MP400S 4 Gas Detector with LEL/O2/CO/H2S Sensors MPAS-21A601-02040
Solider MP400S 4 Gas Detector with LEL/O2/CO/HCN Sensors MPAS-21A601-040A0
Solider MP400S 5 Gas Detector with PID/LEL/O2/CO/H2S Sensors MPAS-21A1A6-010M0

Downloads

mSquad Wireless Detection System literature 
POLI 4 gas detector literature
Tech Note 3 – Calibration Frequency
Tech Note 4 – Sensor Technical Data Summaries
Tech Note 5 – Gas Detectors for Firefighters and Hazmat Teams

Product Enquiry