mSquad Mobile Wireless Multi-Gas Detection System
The mSquad System is a quickly deployable set of mobile multi-gas meters that communicate wirelessly to a Squad leader up to 0.5 miles away
For pricing, please call 1-800-952-3293 or email sales@afcintl.com
Description
The mSquad Wireless Detection System is a quickly deployable set of mobile multi gas meters that communicate wirelessly to a Squad Leader up to 0.5 miles away. The system is ideal for Hazmat Response, fire fighters, temporary venue protection, etc. An mSquad consists of one Head monitors (MP400H) and up to 8 Soldier monitors (MP400S) that communicate with each other. Each 4 or 5 gas monitors has options for a full range of sensors for toxic gases, oxygen, combustible and carbon dioxide. The MP400S can also have a PI for volatile organic compounds (VOCs). In addition to high gas concentration alarms, all Squad units receive any Man-Down alarms to notify them remotely of a worker in distress. All the Squad monitors are Class I, Division I certified to operate in hazardous zones. The entire mSquad is mobile, running on batteries for up to 12 hours. The MP400S and MP400H have rugged construction and easy to learn 2 button operation.
Features
- Remote, wireless real-time readings and alarms including Man-Down
- Up to 8 remote 4- or 5-gas monitors
- Up to 0.5 miles distance to Squad head
- All mSquad units alarm if any one unit has an alarm condition
- Mobile system operation
- 12 hour continuous operation on single Li-ion battery charge
- USB micro cable for battery chageing and direct PC communication
- Wide selection of sensor types
Instrument Specifications
Detector | Electrochemical for Toxic gases and Oxygen Pellistor: Combustible PID: Volatile organic compounds NDIR: LEL, VOL% and carbon dioxide |
Battery | Rechargeable Lithium-ion |
Operating Periods | 8-36 hour depending on configuration |
Graphic Display | 128 x 128 graphical LCD, 1.77 x 1.73″ LED backlight for enhanced display |
Wireless Alarm Notification | Alarm on any monitor sent to all other in mSquad for 5 seconds, then remains on at MP400H |
Direct Readout | Real time reading of gas concentrations PID measurement of gas and correction factor Battery status STEL, TWA, peak and minimum values Man-Down alarm on/off |
Alarm | Audible: 95 dB @ 30 cm Visual: Flashing bright red LEDs Vibration On-screen indication of alarm conditions Man-Down alarm |
EMI/RFI | EMC directive: 2004/30/EC |
IP Rating | Pump: IP-65 Diffusion: IP-67 |
Range | 0.5 miles between MP400H and MP400S |
Frequency | ISM band (902-928 MHz) FCC Part 15 approved |
Data Logging | Continuous datalogging, 6 months for 4 sensors at 1 minute intervals, 24 hours/day and 7 days/week |
Communication & Charging | USB cable for charging, data download, instrument setup and firmware upgrades on PC or 100-240V AC charger, or CaliCase |
Sampling | Built in pump or diffusion |
Calibration | Zero and span calibration, single or multiple sensor simultaneous calibration settings |
Temperature | -4° to 122°F |
Humidity | 0-95% rH, non-condensing |
Size | 5.7″ x 3.3″ x 1.7″ |
Weight | 15.5 ounces |
Approvals | Class I, Div 1, Groups A, B, C, D |
Sensor Specifications
Gas |
Resolution
|
|
Combustible Gas (LEL%) | ||
Oxygen | ||
Carbon Monoxide | ||
Hydrogen Sulfide | ||
PID | ||
Hydrocarbons NDIR (Vol%) | ||
Carbon Dioxide | ||
Carbon Monoxide/Hydrogen Sulfide | H2S: 0.1-200 ppm |
H2S 0.1 ppm |
Sulfur Dioxide/Hydrogen Sulfide | H2S: 0.1-100 ppm |
H2S: 0.1 ppm |
Ammonia | ||
Chlorine | 0.1 ppm | |
Chlorine Dioxide | ||
Hydrogen | ||
Hydrogen Chloride | ||
Hydrogen Fluoride | ||
Hydrogen Cyanide | ||
Nitric Oxide | ||
Nitrogen Dioxide | ||
Phosphine | ||
Sulfur Dioxide | ||
Acetaldehyde | ||
Methyl Mercaptan | ||
Ethylene Oxide |
Ordering Information
The mSquad Wireless Detection System Kits include monitors, hard case with foam, charger with 4 USB ports, 4 USB cables, calibration cup (for Head), 2 calibration adapters (for Soldiers), water trap filters and quick start guide. Many other configurations available, call for details. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description | |
mSquad 4 includes 1 head & 3 soldiers in case, 4 gas monitors with LEL/O2/H2S/CO sensors | M004-0031-000 |
mSquad 4 includes 1 head & 3 soldiers in case, 4 gas monitors with LEL/O2/HCN/CO sensors | M004-0032-000 |
mSquad 4 includes 1 head & 3 soldiers in case, 5 gas monitors with PID/LEL/O2/H2S/CO sensors | M004-0033-000 |
mSquad 8 includes 1 head & 7 soldiers in case, 4 gas monitors with LEL/O2/H2S/CO sensors | M004-0035-000 |
mSquad 4 includes 1 head & 7 soldiers in case, 4 gas monitors with LEL/O2/HCN/CO sensors | M004-0036-000 |
mSquad 4 includes 1 head & 7 soldiers in case, 5 gas monitors with PID/LEL/O2/HCN/CO sensors | M004-0037-000 |
Solider MP400S 5 Gas Detector with PID/LEL/O2/CO/H2S Sensors | MPAS-21A1A6-010M0 |
Solider MP400S 4 Gas Detector with LEL/O2/CO/H2S Sensors | MPAS-21A601-02040 |
Solider MP400S 4 Gas Detector with LEL/O2/CO/HCN Sensors | MPAS-21A601-040A0 |
Solider MP400S 5 Gas Detector with PID/LEL/O2/CO/H2S Sensors | MPAS-21A1A6-010M0 |
Downloads
Product Literature
POLI 4 gas detector literature
Tech Note 3 – Calibration Frequency
Tech Note 4 – Sensor Technical Data Summaries
Tech Note 5 – Gas Detectors for Firefighters and Hazmat Teams
Product Enquiry
Related products
-
MultiRAE Benzene with Benzene Specific Measurement
Ships directly from the manufacturer, shipping times may vary.
-
Honeywell BW RigRat Transportable Multi-Gas Area Monitor
Ships from the manufacturer, shipping times may vary
-
mPlatoon Mobile Wireless Multi-Gas Detection System
Ships from the manufacturer, shipping times may vary ships in 1 week
-
MultiRae Wireless Six Gas Monitor with VOC Detection
Ships from Manufacturer, shipping times can vary