Choose the Midas Gas Detector to detect more than 35 gases – easily, quickly and error free. All with extended sensor calibration periods, patented diagnostics and lower cost of ownership. The Midas Gas Detector uses reliable sensor technology to detect many key toxic, ambient and flammable gases in a plant. Thee device monitors points up to 100 fee away while using patented technology to regulate flow rates and ensure error free gas detection. Thanks to Honeywell’s use of advanced robotics, the Midas Gas Detector offers unbeatable quality and reliability.
The Midas is equipped with bright LED lights and an intuitive, interactive interface that provides instant alerts to gas reading or alarm levels. The interface also includes password protected menus for configuration, test and calibration. With it’s compact size and easy to handle metal chassis, installation is very easy. The Midas Gas Detector is complemented by Honeywell’s innovative ChemCassette technology, which detects ultrasensitive toxic gases at low parts per billion (ppb) levels. Honeywell offers 24/7 support of a worldwide network of service engineers. With feature-rich capabilities that are easy to use, the Midas Gas Detector is suitable for many industry applications, including semiconductor processing, light industrial manufacturing, university laboratories, aerospace, wastewater and more.
With flexible features and options, the Midas works right out of the box and configures easily to meet your needs. Each plug and play sensor cartridge is pre-calibrated, so it’s ready when you are. That means longer sensor life, quick and easy replacement and no operator error due to incorrect or depleted sensors.
The standard power supply and communications capabilities include three onboard relays, 0-22 mA analog output and Modbus/TCP Ethernet digital outputs. Plus, the Midas includes the innovative Power over Ethernet (PoE) protocol – a single Ethernet connection for all power, control and communication requirements. Thanks to the Midas architecture, cost-effective integration with PLC and Fieldbus systems is greatly simplified.
Offered as an option, the Midas Pyrolyzer allows for the detection of NF3 and other CxFy gases. Cost of ownership is low, as the Pyrolyzer has a replaceable heater assembly with a lifespan of greater than two years. Even more, thanks to the proprietary catalyst to improve efficiency in gas conversion, the Pyrolyzer delivers automatic flow control, temperature control and fast and accurate performance. Additionally, the Pyrolyzer can run from a Midas Gas Detector that’s powered by either PoE or 24 VDC.
Features
- Over 35 gases available with extended 2 year warranty*
- Smart sensor cartridge with on board “e-calibration’ certificate
- 3 built in relays (Form C) for Alarm 1, 2 and Fault
- Power over Ethernet (PoE) communication
- Keypad interface and remote web browser interface
- Optional Midas Pyrolyzer module that connect to any Midas gas detector
- Password protected menu levels to preserve system integrity
- Bright LEDs and intuitive icon driven, large multicolor backlit LCD display
- Factory-calibrated sensors to reduce the need for frequent gas testing
- Isolated 0-22 mA analog output with fault and event reporting
- Modbus/TCP Ethernet for easy connectivity to all control and alarm system ports for control connectivity and service interaction
- Robust extractive pump systems (2 year lifetime) sampling up to 100 feet
- CE marked for total immunity to Radio Frequency Interference
- Reflex sensor health check for improved safety
- TempraSure temperature compensation technology as appropriate
- Event logging to review sensor history
*Standard warranty is 1 year
Specifications
Display |
4 digit alphanumeric display with separate units, flow rate bar graph and other icon driven indicators, 4 button interface keypad, Optional remote for PC/PDA internet browser access vie Ethernet |
Flow Rate |
500 ml/min |
Transport Time |
2 to 30 seconds maximum |
Sample Line Tubing |
0.125″ id x 0.25″ od, up to 100′ long with FEP tubing |
Exhaust Line Tubing |
0.25″ id x 0.375″ ID, up to 100 feet long |
Ambient Point |
In-line air filter required |
Visual Output |
Alarm, Power and Fault LEDs, LCD display with all gas readings and events |
Relays |
3 relay for Alarm 1, Alarm 2 and Fault rate 30 VDC, 1 A or 125 VAC, 0.5 A, configurable NO or NC, latched or unlatched |
Analog Output |
3 wire sink, 3 wire source or 4 wire fully isolated, 0 to 21 mA |
Digital Communications |
Modbus, TCP Ethernet, Power over Ethernet (PoE), Lonworks |
Service Port |
RS232C, PPP protocol |
Operating Voltage |
24VDC, -15 to +10% |
Operating Voltage with PoE |
48 VDC via PoE |
Power Consumption |
Transmitter: <5W
Pyrolyzer: <12.95W
Lonworks: <8W
Lonworks & Pyrolyzer: <15.95EW |
Wiring Requirements |
4-20mA: 2 wire, 14 AWG maximum
Digital: CAT5 Cable of equivalent, RJ45 connector |
Installation |
Wall mounted using pre-drilled holes on chassis, options for DIN rail or vertical bracket mounting |
Operating Temperature |
Unit Only: 32 to 104°F
Unit with Pyroylzer: 32 to 86°F |
Size |
Transmitter: 5.91″ x 2.56″ x 6.02″
NF3 Pyrolyzer: 2.75″ x 4.0″ x 3.35″
High Temp: PFC Pyrolyzer: 3.9″ x 4.0″ x 5.5″
OP3 Pyrolyzer: 5.2″ x 2.4″ x 3.9″
NP1 Pyrolyzer: 5.02″ x 2.56″ x 5.29″ |
Weight |
Transmitter: 1.76 pounds
NF3 Pyrolyzer: 0.8 pounds
High Temp PFC Pyrolyzer: 3 pounds
OP3 Pyrolyzer: 2.65 pounds
NP1 Pyrolyzer: 1.8 pounds |
Warranty |
Transmitter: 1 year
Sensor Cartridge: 1 year standard, 2 years extended
Expected Pyrolyzer Life: MIDAS-T-00P: 1 YEAR, MIDAS-T-NP1: 2 years |
Sensor Specifications and Catalog Numbers
Sensor |
Range |
Catalog No. |
Ammonia (NH3) |
0-100 ppm |
MIDAS-E-HN3 |
Arsine (AsH3) |
0-200 ppb |
MIDAS-E-ASH |
Boron Trichloride (BCl3) |
0-8 ppm |
MIDAS-E-HCL |
Boron Trifhloride (BF3) |
0-8 ppm |
MIDAS-E-HFX |
Boron Trifluoride (BF3), Low Level |
0-2 ppm |
MIDAS-E-HFL |
Bromine (Br2) |
0-0.4 ppm |
MIDAS-E-BR2 |
Butane (n-C4H10) |
0-100 % LEL |
MIDAS-E-LEB |
Carbon Dioxide (CO2) |
0-2% |
MIDAS-E-CO2 |
Carbon Monoxide, (CO)Low H2 interference |
0-100 ppm |
MIDAS-E-COH |
Carbon Monoxide (CO) |
0-100 ppm |
MIDAS-E-COX |
Chlorine (Cl2) |
0-2 ppm |
MIDAS-E-HAL |
Chlorine Dioxide (ClO2) |
0-0.4 ppm |
MIDAS-E-BR2 |
Diborance (B2H6) |
0-400 oob |
MIDAS-E-B2H |
Dichlorosilane (H2Cl2Si) |
0-8 ppm |
MIDAS-E-HCL |
Difluoromethane** (CH2F2) |
0-240 ppm |
MIDAS-E-XCF |
Disilane (Si2H6) |
0-20 ppm |
MIDAS-E-SHX |
Ethylene (C2H4) |
0-100% LEL |
MIDAS-E-LEL |
Fluorine (F2) |
0-4 ppm |
MIDAS-E-HAL |
Germane (GeH4) |
0-4 ppb |
MIDAS-E-ASH |
Hexafluorobutadiene** (C4F6) |
0-40 ppm |
MIDAS-E-CFX |
Hydrogen %LEL (H2) |
0-100% LEL |
MIDAS-E-LEL* |
Hydrogen ppm (H2) |
0-1,000 ppm |
MIDAS-E-H2X |
Hydrogen Bromide (HBr) |
0-8 ppm |
MIDAS-E-HCL |
Hydrogen Chloride (HCl) |
0-8 ppm |
MIDAS-E-HCL |
Hydrogen Cyanide (HCN) |
0-20 ppm |
MIDAS-E-HCN |
Hydrogen Fluoride (HF) |
0-12 ppm |
MIDAS-E-HFX |
Hydrogen Fluoride Low Level (HF) |
0-2 ppm |
MIDAS-E-HFL |
Hydrogen Sulfide (H2S) |
0-40 ppm |
MIDAS-E-H2S |
Methane %LEL (CH4) |
0-100% LEL |
MIDAS-E-LEL* |
Methyl Fluoride ** |
0-120 ppm |
MIDAS-E-XHF |
Nitric Oxide (NO) |
0-100 ppm |
MIDAS-E-NOX |
Nitrogen Dioxide (NO2) |
0-12 ppm |
MIDAS-E-NO2 |
Nitrogen Triflouride ** (NF3) |
0-40 ppm |
MIDAS-E-HFX |
Octane (n-C6H18) |
0-100% LEL |
MIDAS-E-LEO |
Octofluorocyclopentene** (C6F8) |
0-40 ppm |
MIDAS-E-XCF |
Oxygen (O2) |
0-25% v/v |
MIDAS-E-O2X |
Ozone (O3) |
0-0.7 ppm |
MIDAS-E-O3H |
Ozone Low Level (O3) |
0-0.4 ppm |
MIDAS-E-O3X |
Phosphine (PH3) |
0-1,200 ppb |
MIDAS-E-PH3 |
Propane (C3H8) |
0-100% LEL |
MIDAS-E-LEX |
Propylene (C3H6) |
0-100% LEL |
MIDAS-E-LEL |
R134a (C2H2F4) |
0-1,000 ppm |
MIDAS-E-XCF |
Silane (SiH4) |
0-20 ppm |
MIDAS-E-SHX |
Silane Low Level (SiH4) |
0-2 ppm |
MIDAS-E-SHL |
Sulfur Dioxide (SO2) |
0-8 ppm |
MIDAS-E-SO2 |
Tetra Ethyl Ortho Silicate (TEOS) |
0-40 ppm |
MIDAS-E-TEO |
Tungsten Hexafluoride (WF6) |
0-12 ppm |
MIDAS-E-HFX |
Tungsten Hexafluoride Low Level (WF6) |
0-2 ppm |
MIDAS-E-HFL |
*MIDAS-E-LEL cartridge carries a 2 year warranty but can be calibrated up to 5 years
** Gases require Midas Pyrolyzer
Midas detectors are not ETL approved for monitoring in or sampling from classified areas above 25% LEL