SR500 Powered Air Purifying Respirator (PAPR)

The Sundstrom SR500 Powered Air Purifying Respirator System is a belt mounted with tight fitting face pieces, loose fitting respirators or loose fitting hoods that protects against particulates, gases and vapors or a combination.

or pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description

The Sundstrom SR500 Powered Air Purifying Respirator PAPR System is a belt mounted with tight fitting face pieces, loose fitting respirators or loose fitting hoods that protects against particulates, gases and vapors or a combination. It is designed to be used in oxygen sufficient and non-immediately dangerous to life and health (IDLH) environments.

The SR500 powered air purifying respirator PAPR system functions as an alternative to air purifying respirators (APR) in all situations for which these are recommended. This applies particularly to work that is hard, warm or of long-duration. The filtered air is supplied through a breathing hose to the tight fitting face piece, loose fitting respirator or loose fitting hoods. The above-atmospheric pressure then generated prevents surrounding pollutants from penetrating into the breathing zone.

Typical applications include agriculture, asbestos, mold and lead paint abatement, construction & building renovation, demolition, chemical industry, food & beverage processing, lead battery plants, medical & healthcare, metal work, pharmaceutical manufacturing, power plants, pulp & paper processing, recycling plants, smelting and foundries, surface preparation, painting, coating and more.

Features

  • The fan unit is lightweight, balanced with a superior ergonomic design
  • Unique design of the belt keeps that fan unit comfortable and stable
  • High flow rates, normal operation mode of 6 CFM/175 LPM and boosted operation mode of 8 CFM/225 LPM
  • A fully automatic setting of flow rates without any needs for calibration, independent of filter/cartridges or head top used
  • The power switch is conveniently located and easy to reach
  • The fan unit offers audible, visual, vibration alarm for obstruction of air flow, clogging of filters or low battery for the safety of the worker
  • The fan unit can be used with HE particulate filters only or with a filter combination with chemical cartridges

SR520 is a loose-fitting hood and SR 500 belt mounted Powered Air-Purifying Respirator (PAPR) protects against particulates, gases and vapors, or a combination. The SR520 hood is available in two sizes (S/M) and (M/L).

Safety helmet SR580 with a gold plated shield (SR587). Suitable when work is performed in extreme heat as the shield significantly reduces radiant heat.

Safety helmet SR580 with visor EN 3 (SR588-1). The visor protects against light emissions arising during welding and cutting operations and have a very good optical clarity.

Safety helmet SR580 with visor EN 5 (SR588-2). The visor protects against light emissions arising during welding and cutting operations and have a very good optical clarity.

SR530 loose-fitting hood and SR500 belt mounted Powered Air-Purifying Respirator (PAPR) protects against particulates, gases and vapors, or a combination. The SR530 hood is available in one size.

The SR580 Loose Fitting Hard Hat together with the SR500 belt mounted Powered Air-Purifying Respirator (PAPR) protects against particulates, gases and vapors, or a combination of both. It is designed to be used in oxygen sufficient and non-immediately dangerous to life and health (IDLH) environments. The SR500 PAPR system functions as an alternative to Air Purifying Respirators (APR) in all situations for which these are recommended. This applies particularly to work that is hard, warm or of long-duration. The filtered air is supplied through a breathing hose to the SR580 Loose Fitting Hard Hat. The above-atmospheric pressure generated prevents surrounding pollutants from penetrating into the breathing zone.

The SR580 Loose Fitting Hard Hat with the SR584 Welding Face Shield together with the SR500 belt mounted Powered Air-Purifying Respirator (PAPR) protects against particulates, gases and vapors, or a combination of both. It is designed to be used in oxygen sufficient and non-immediately dangerous to life and health (IDLH) environments. The SR 500 PAPR system functions as an alternative to Air Purifying Respirators (APR) in all situations for which these are recommended. This applies particularly to work that is hard, warm or of long-duration. The SR580/ SR584 also protects against radiation and spatter during welding, flame-cutting, grinding and similar work. The design makes them useful for work in confined and inaccessible areas. Accessories in the form of automatic welding lenses, correction lenses, neck and chest protection and hose protection.

The SR570 face shield is a modern, innovative product, designed and developed based on the needs and requirements from the market. The SR 570 is a robust shield with a flip-up visor, and gives the user comfortable and safe respiratory and eye protection. The face shield is fitted with an attachment for hearing protectors. A wide range of accessories enable the user to customize the shield for their work situation. The shield is manufactured in a material that permits use in tough environments. The SR570 shield can be used with SR500 PAPR.

The on board Lithium-Ion battery is designed for easy removal and replacement. It features a charging time of 70 minutes for 80% and 3 hours for 100% capacity. The 3 stage battery charges has a boosted charging that charges the battery to about 80% of its capacity, balanced charging charges the battery to 100% of its capacity while trickle charging has a fully charged battery. Gang charges are available.

The SR510P100/HE and SR710HE particulate filters are both mechanical type and protects against all types of particles (dust, fume, fog, spray and asbestos) as well as bacteria, viruses and radioactive dust. The filter efficiency is >99.997% meaning that the air is 33,000 times cleaner on the backside of the filter media than in the front. The active filter area is 20 square inches which generates an extended usage time. The SR510 can also be used with all Sundstrom air purifying respirators.

The SR532 OV/SD/CL/HC/HF chemical cartridge protects against organic gases and vapors, (solvents, with a boiling point of more than +65°C). It protects against acidic gases and vapors, such as sulfur dioxide, chlorine, hydrogen chloride and hydrogen fluoride.

The SR533 CL/HC/SD/FM/AM/MA chemical cartridge protects against acidic gases and vapors such as chlorine, hydrogen chloride, sulfur dioxide and formaldehyde. It also protects against ammonia, methylamine and certain amines.

Note: that each cartridge should be combined with a particulate filter to prolong the lifetime of the fan unit.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
SR500 PAPR with SR520 Hood, size M/L includes fan unit, hood with breathing hose, battery, battery charger, belt, flow meter, filter covers and 2 each HE particulate filters
H06-0621
SR500 PAPR with SR200 Full Face Mask includes fan unit, full face mask, breathing hose, battery, battery charger, belt, flow meter, filter covers, and 2 each HE particulate filters
H06-0821
SR500 PAPR with SR530 Hood includes fan unit, hood with breathing hose, battery charger, belt flow meter, filter covers and 2 each HE particulate filters
H06-0921
SR580 PAPR with SR570 Bump Cap, includes fan unit, bump cap, breathing hose, battery, battery charger, belt flow meter, filter covers and 2 HE particulate filters
H06-6621
SR500 PAPR with SR580 Hard Hat, APF 1,000 includes fan unit, hard hat, breathing hose, battery, battery charger, belt, flow meter, filter covers and 2 each HE particulate filters H06-8121
SR500 PAPR with SR580 /SR584 Hard Hat, APF 1,000 & Welding Shield includes fan unit, hard hat, welding shield, passive welding lens shade 10, breathing hose, battery, battery charger, belt, flow meter, filter covers, and 2 eah HE particulate filters H06-8421
SR520 Hood, Size M/L
H06-0221
SR520 Hood, Size S/M
H06-0321
SR530 Hood
H06-0421
SR570 Face Shield H06-6521
SR580 Hard Hat with Visor H06-8021
SR580 Hard Hat with Visor & Welding Shield H06-8321
SR580 Hard Hat with Fold Visor for Heat Protection H06-8521
SR580 Hard Hat with Shade 3 Visor for Welding H06-8621
ST580 Hard Hat with Shade 5 Visor for Welding H06-8721
Gold Visor for Heat Protection R06-0824
Visor Shade for various types of welding, 2/3 Shade 3 R06-0825
Visor Shade for various types of welding, 2/3 Shade 5 R06-0826
SR710 HE Particulate Filter
H02-1521
SR532 OV/SD/CL/HC/HF Cartridge
H02-7121
SR533 CL/HC/SD/FM/AM/MA Cartridge
H02-7221
SR516 Gang Charger
H06-01111

Downloads

SR500 Powered Air Purifying Respirator Literature