SEC Millennium IR High Range Ammonia Gas Detector

The SEC IREvolution high range ammonia detector is designed to be used as an upgrade in the same applications where electrochemical sensors have been applied. The Millennium is a complete self contained optical ammonia gas detector. The sensing and reference elements are self-compensating for optical integrity and other signal inhibitors. The industry standard 4-20 mA analog output provides remote alarm, fault and calibration signals.

Features

  • Reliable infrared sensing technology
  • Virtually maintenance free
  • Low cost of ownership, over ten years operating life
  • Immune to poisoning and etching
  • Designed for harsh environments
  • Explosion proof
  • Fast response time
  • Smart calibration
  • Patented self compensating optical bench and no moving parts
  • Heated optical chamber
  • Low power consumption
  • Operates in constant ammonia background and anaerobic atmosphere
  • Fault indications for all failure states
  • Routine calibrations are not required
  • 4-20 mA output, HART enabled
  • 0 to 100% LFL detection range
  • Digital display optional

Specifications

Detectable Gases Ammonia
Range 0-1,000 ppm
0-2,500 ppm
0-10,000 ppm
0-10% Vol
Accuracy ±5% of value or ±0.5% of full scale
Detection Method Diffusion, optional sample draw, requires a minimum of 1 LPM flow rate
Power Consumption 5 watts
Analog Output 4-20 mA, max 1,000 Ohm load at 24 VDC supply voltage
Response Time T50 < 10 seconds, T90 < 20 seconds
Operating Temperature -40 to 70°C, 0-99% RH, non condensing
Operating Range 18 to 32 VDC measured at detector head
Max Current Draw Average 210 mA, Peak 400 mA
Construction Anodized aluminum, 316 stainless steel
Classification Class I, Div I, Groups B, C, D, T5
IECex Class 1, Zone 1 Group IIC
Dimensions 11″ x 2.75″
Installation Category Cat I, Pollution Degree 2
Weight 3 pounds

Unit Status Chart

Current
Output
Status
4-20
mA
Normal measuring mode
0.6
mA
Unit fault
0.8
mA
Reference channel fault
0.9
mA
Analytical channel fault
0.7
mA
Unit warm up
1.0
mA
Optics fault
1.2
mA
Zero drift fault
1.6
mA
Calibration fault
2.0
mA
Unit spanning
2.2
mA
Unit zeroing
4.0
mA
Zero gas level
5.6
mA
10% of full scale
8.0
mA
25% of full scale
12
mA
50% of full scale
16
mA
75% of full scale
20
mA
100% of full scale
20.1-23
mA
Over range (>100%)

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
SEC Millennium Infrared Ammonia Gas Detector, 0-1,000 ppm 5100-012
SEC Millennium LC Infrared Ammonia Gas Detector, 0-2,500 ppm
5100-011
SEC Millennium LC Infrared Ammonia Gas Detector, 0-10,000 ppm 5100-001
SEC Millennium LC Infrared Ammonia Gas Detector, 0-10% Vol 5100-013