You are here:

RaeGuard 2 PID Fixed Detector for VOCs

Get A Quote

The RaeGuard 2 PID from Honeywell by Rae Systems operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire single output, and RS-485 Modbus digital signal output.

For best pricing, please call 1-800-952-3293 or email us at sales@afcintl.com

Description

Description

The RaeGuard 2 PID is a fixed photoionization detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RaeGuard 2 PID from Honeywell by Rae Systems operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire single output, and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibrations and maintenance.

The RaeGuard 2 PID has a graphic display and LED light status indicator for fault and alarm conditions. In addition, Low, High and Fault relays can be configured to trigger external alarms or process controls. Over 200 correction factors are pre-programmed and allow users to display readings of a specific target gas. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

 

Features

  • Class 1, Division 1 (Zone 1) continuous VOC monitoring solution for hazardous locations
  • Three wire 4-20 mA analog output and RS-0485 digital communication in ModBus protocol
  • Three dry contact relays (<30V, 2A) normally open (or normally closed), one for High and Low alarm, another for Fault alarm
  • Explosion proof stainless steel enclosure suitable for outdoor hazardous environment applications
  • Magnetic key interface eliminates the need to open the explosion proof housing when adjusting parameters
  • Continuous VOC monitoring in hazardous and non-hazardous area locations
  • Reduced maintenance costs due to easily removable sensor module. Sensor and lamp can be removed without tools and serviced in hazardous locations
  • Faster response time with sample flow through design powered by internal diaphragm pump
  • Humidity compensation ensures accurate readings even in humid environments

Specifications

Power Supply 5V±0.25VDC
Current 110 mA max
Power Consumption <0.6 W
Measuring Range 0.01 to 100ppm
0.1 to 1,000 ppm
1 to 1,000 ppm (no relays or correction factors)
Resolution 10 ppb, 1 ppm depends upon model
Response Time Pumped – T90: <30 seconds
Calibration Two point off line and field calibration, optional three point calibration
Accuracy ±2% for calibration point
Analog Output 0.5 – 2.5 (ro=1.0K)
Digital Interface Serial Interface (UART)
Transmit (Tx): 3.3 V TTL
Receive (Rx): 3.3 V TTL
Warranty 2 years for lamp, 1 year for housing and electronics
Operating Temperature -4ºF to 131ºF
Humidity 0-95% RH non-condensing
EMI/RFI Highly resistant to EMI/RFI, compliant with EMC Directive 2004/108/EC
Package 316 Stainless Steel, spray watertight for IP65 rating, dust membrane for sensor front protection
Size 1.92″ x 5.95″
Weight 19.4 ounces

Specifications – Fixed Sensor Head

Working Current DC 10 to 28V, 210 mA at 24V
Power <5W
Output 4-20ma
Three level programmable alarm relays
RS-485 support Modbus
Sampling Internal diaphragm pump, adjustable up to 500cc/min
IP Rating IP-65
Mechanical Interface ¾” NPT Male
Installation 2″ pipe holding or wall mounting
User Interface Three key magnetic bar adjustment
Calibration Two Point
Warranty  1 year for pump, 2 years for housing and electronics
Material 316 stainless steel
Operating Temperature -4ºF to 131ºF
Humidity 0-95% RH non-condensing
Pressure 90 to 110 kPa
Display 128 x 65 matrix backlit LCD, supports graphic display
Size 10.1″ x 7.9″ x 4.2″
Weight 7.7 pounds
Certifications ATEX: EX II 2 (1) G Ex d (ia GA_) IIC T4 Gb
UL/CSA: Class I, Div I, Groups A, B, C , D, T4
IECEx: Ex d (ia Ga) IIC T4 Gb

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
RaeGuard 2 PID Kit, 0.01 – 100 ppm range H-D03-0009-000
RaeGuard 2 PID Kit, 0.1 – 1,000 ppm range H-D03-0010-000
RaeGuard 2 PID, 1 – 1,000 ppm range, Note: Correction factors and relays are not available H-D03-0012-000
DigiPid Sensor Module, 0.01 – 100 ppm range, IS Approved C01-0001-000
DigiPID Sensor Module, 0.1 – 1,000 ppm range, IS approved C01-0002-000
DigiPID Sensor Module, 1 – 1,000ppm range, IS approved C01-0004-000
DigiPID Internal Dust Filter, pk/5 C01-2034-005
DigiPID External Water Trap Filter, pk/5 490-0011-005
DigiPID Teflon UV Electrode Shield, pk/10 C01-2017-010
DigiPID Lamp, 10.6 eV 1/2: 050-0000-003
DigiPID Replacement Sensor Kit C01-3007-100
DigiPID Flowthrough Adapter, SS C01-3012-000

Downloads

RaeGuard 2 PID Detector literature

Product Enquiry