Description
The GX-Force Multi Gas Detector is RKI’s smallest personal 1-4 gas monitor with a strong internal sample pump capable of a 100’ sampling range. Weighing only 9.8 ounces, the GX-Force can monitor the standard confined space gases (LEL combustibles, Oxygen, Carbon Monoxide, and Hydrogen Sulfide). Built around high-quality micro-sensor technology, which are compatible with the GX-3R, GX-3R Pro, 04 Series, and Gaswatch 3 instruments.
With the GX-Force, you have multiple tools in one instrument. Having 2 operating modes, the GX-Force can be used for confined space, safety monitoring in its Normal Operating mode. A Leak Check mode is the solution for all leak investigations.
The GX-Force operates 30 hours on a Li-ion battery, and has a large LCD display showing all gas readings, battery level, current time and automatically backlights in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-Force continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors.
Calibration and bump test intervals and reminders are user adjustable and can be set to either go into alarm or to lock the user out of normal measurement mode once a calibration period has expired. Calibration can be done individually or in a group.
In Leak Check Mode, the GX-Force, can monitor for combustibles in the ppm range.
Features
- 2 Operating modes: Normal and Leak Check
- Internal sample pump with 100′ sample range
- 30 hours of operation
- USB Type-C charging & data connection
- Easy to grip lightweight design
- Water and dust resistant design
- Field replaceable sensors & filters
- Impact resistant body
- Intrinsically safe
- Large LCD Auto-backlit display
- 3 Year warranty
Specifications
Sample Method | Internal pump, 0.5 LPM flow rate |
Flow Rate | Minimum 35 LPM |
Battery | Rechargeable Lithium-Ion battery, about 30 hours run time |
Alarm | System, clock or sensor abnormality, battery voltage drop, calibration failure, pump abnormality, low flow rate |
Display | Digital LCD with backlight |
Communications | USB: 2.0 for datalogger Connector: Type-C |
Datalogging | Maximum storage: 3,600 points at 5 minute intervals (adjustable) |
Enclosure | IP-67 equivalent |
Temperature | -4 to 122°F |
Humidity | 0% to 95% relative humidity (non-condensing) |
Intrinsic Safety | ATEX and IECEx |
Size | 2.52″ x 6.81″ x 1.85″ |
Weight | 9.87 ounces |
Warranty | 3 Year warranty |
Sensor Specifications
Sensor |
A1/A2
|
|
Combustible | ||
Carbon Monoxide (CO) | 0 – 2,000 ppm | 25 ppm/50 ppm |
Hydrogen Sulfide (H2S) | 0 – 200.0 ppm | 5 ppm/30.0 ppm |
Oxygen (O2) | 0 – 40% Vol | 19.5 % Vol/18.0% Vol |