You are here:

Chlorine Dioxide Replacement Sensor for AreaRae / MultiRae / ToxiRae Pro

Ships directly from the manufacturer, shipping times may vary.

$585.00

Description

Description

Genuine Chlorine Dioxide Replacement Sensor for AreaRae / MultiRae / ToxiRae Pro gas detectors from Rae Systems by Honeywell.

All specifications have been verified under the following environmental conditions:

  • Temperature: 68°F
  • Relative Humidity (non-condensing): 50%
  • Ambient Pressure: 1 atm (1,013 mbar)

Refer to the Technical Note TN-114 for a glossary of terms used on this page

Additional information

Weight .5 lbs

Specifications

Sensor Type Electrochemical
Range 0-1 ppm
Resolution 0.01 ppm
Bias/Equilibration No bias/10 minutes after installation
Drift < 5% signal loss/6 months
Storage Life 6 months in sealed container
Operating Life 2 years in air
Calibration Gas 0.8 ppm Chlorine Dioxide from gas generator
Temperature Effect <0.02 ppm increase from -4°F to 104°F
Temperature Range -4°F to 104°F
Storage Temperature Range 32°F to 68°F
Pressure Range Atmospheric ±10%
Operating Humidity 5 to 95% rH non-condensing
Warranty 1 year from date of shipment

Cross Sensitivities

Gas
Concentration
Response
Alcohols
1,000 ppm
0 ppm
Arsine 1 ppm 0.8 ppm
Chloropicrin
100 ppm
0 ppm2
Chlorine
1 ppm
0 ppm1
Chlorine
1 ppm
0.6 ppm2
CCIF3 1 ppm 1 (theor) ppm
Carbon Monoxide
1,000 ppm
0 ppm
Carbon Monoxide 50 ppm 0 ppm2
Carbon Dioxide
5,000 ppm
0 ppm
Hydrogen 10,000 ppm 0 ppm
Hydrogen Sulfide
10 ppm
0 ppm1
Hydrogen Sulfide
20 ppm
-5 ppm2,3
Hydrogen Chloride
5 ppm
0 ppm
Hydrogen Selenide 0.1 ppm 0 ppm
Hydrogen Cyanide
10 ppm
0 ppm
Hydrogen Fluoride 3 ppm 0 ppm
Hydrocarbons
% range
0%
Ammonia
50 ppm
0 ppm2
Nitric Oxide
25 ppm
0.9 ppm2
Nitrogen Dioxide 5 ppm 2.3 ppm2
Ozone
0.1 ppm
0.03 ppm
Phosphine 300 ppm 0.3 ppm
Sulfur Dioxide
5 ppm
0 ppm2

1 – Short exposure of <few minutes of <100 ppm with filters
2 – With onboard filters removed
3 – CAUTION! Negative cross sensitivities may cause the sensor to produce lower readings than the true concentration of gas in ambient air. Chlorine Dioxide sensors without on board filters have a negative cross sensitivity to hydrogen sulfide and other reducing gases and may underestimate the Chlorine Dioxide concentration if Hydrogen Sulfide is present.

Downloads

Technical Note: TN-114 – Sensor Specifications and Cross Sensitivities for Chlorine Dioxide Replacement Sensor

Disclaimer: Technical Note TN-114 presents specifications, cross sensitivities and calibration information on select Rae Systems by Honeywell sensors. All specifications presented in this Technical Note reflect the performance of standalone sensors. For instrument specifications, please refer to product datasheets and manuals. Actual sensor characteristics may differ when the sensor is installed in different instruments. As sensor performance may change over time, specifications provided are for brand new sensors.

Product Enquiry