UNI Single Gas Detector

The UNI Single Gas Detector, MP100 offers a simple, personal protection for a wide array of toxic gas and oxygen measurement applications.

Prices start at $188.00

For pricing, please call 1-800-952-3293 or email sales@afcintl.com

The UNI Single Gas Detector, MP100 offers a simple, personal protection for a wide array of toxic gas and oxygen measurement applications. In addition to common sensors such as carbon monoxide (CO), hydrogen sulfide (H2S), Nitrogen Dioxide (NO2), Ammonia, (NH3), and Sulfur Dioxide (SO2), mPower offers less common sensors including Chlorine (Cl2), Chlorine Dioxide (ClO2), Hydrogen Fluoride (HF), Phosphine (PH3), Ozone (O3), Methyl Mercaptan and Ethylene Oxide. The monitors have a large LCD providing maximum readability in the field and are made with six bright red LEDs allowing for quick alarm notification. Constructed of a strong and durable material, the UNI is designed to be comfortable, yet drop resistant. The UNI series can easily be bump tested and calibrated with the CaliCase System.

Features

  • 50% larger Lithium battery (AA versus 2/3AA)
  • Widest choice of sensors on the market
  • Large display
  • 50 event datalogging
  • Low cost of ownership
  • Smart sensors
  • Solid stainless steel alligator clip
  • Durable housing
  • Fast calibration and download using the CaliCase Docking Station

Specifications

Alarm Type High, Low, STEL & TWA, adjustable, over range, low battery alarm
Alarm Signal 90 dB @ 30 cm
Bright red LEDs
Built in vibrator
Calibration 2 point calibration, zero & span, power on zero, user selectable
Event Log Up to 50 alarm events
Response Time(t90) 20 seconds for (CO, H2S, O2), other sensor vary
IP Rating IP67
EMI/RFI Compliant with EMC2004/108/EC
Battery Replaceable AA size Lithium battery, 3 years typical operation
Sensor Life CO & H2S expected operating life 5 years or longer
All other sensors 2 years of longer
Temperature -4°F to 122°F
Humidity 5 to 95% rH, non-condensing
Size 3.46 x 2.44 x 1.3″
Weight 4.4 ounces
Intrinsic Safety Class I, Div 1, Groups A, B, C, D
Class II, Div 1, Groups E, F, G
Class III, Div 1
Warranty O2, CO, H2S, SO2, HCN, NO, NO2, PH3: 2 years
All others: 1 year

Sensor Specifications

Sensor
Range
Resolution
Ammonia (NH3)
0 – 100 ppm
1 ppm
Carbon Monoxide (CO)  0 – 500 ppm 1 ppm
Carbon Monoxide (CO)  0 – 1,000 ppm  1 ppm
Carbon Monoxide (CO)  0 – 2,000 ppm  1 ppm
Chlorine (Cl2)  0 – 50 ppm  0.1 ppm
Chlorine Dioxide (ClO2)  0 – 1 ppm  0.01 ppm
Ethylene Oxide (EtO)  0 – 100 ppm 0.1 ppm
Ethylene Oxide (EtO)  0 – 200 ppm  0.1 ppm
Hydrogen (H2)  0 – 1,000 ppm  1 ppm
Hydrogen (H2) 0 – 2,000 ppm 1 ppm
Hydrogen Cyanide (HCN) 0 – 100 ppm 1 ppm
Hydrogen Chloride (HCl)  0 – 15 ppm  0.1 ppm
Hydrogen Fluoride (HF)  0 – 10 ppm  0.1 ppm
Hydrogen Sulfide, (H2S)  0 – 50 ppm 0. 1 ppm
Hydrogen Sulfide, (H2S)  0 – 100 ppm
0.1 ppm
Hydrogen Sulfide, (H2S)  0 – 200 ppm  0.1 ppm
Methyl Mercaptan (CH3SH)  0 – 10 ppm  0.1 ppm
Nitrogen Dioxide (NO2)  0 – 20 ppm  0.1 ppm
Nitric Oxide (NO)  0 – 250 ppm  1 ppm
Oxygen (O2)  0 – 25% Vol  0.1% Vol
Oxygen (O2) 0 – 30% Vol 0.1% Vol
Ozone (O3) 0 – 1 ppm 0.02 ppm
Phosphine (PH3) 0 – 20 ppm 0.1 ppm
Sulfur Dioxide (SO2) 0 – 20 ppm 0.1 ppm
Tetrahydrothiophene (THT) 0 – 50 ppm 0.1 ppm
Acetaldehyde (C2H4O) 0 – 20 ppm 0.1 ppm

Ordering Information

The UNI single gas detector includes AA size Lithium battery, alligator clip, quick reference guide and cal adapter. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
UNI for Carbon Monoxide, 0-500 ppm
M001-0002-000
UNI for Carbon Monoxide, 0-1,000 ppm
M001-0023-000
UNI for Carbon Monoxide, 0-2,000 ppm
M001-0026-000
UNI for Hydrogen Sulfide, 0-50 ppm
M001-0003-000
UNI for Hydrogen Sulfide, 0-100 ppm
M001-0054-000
UNI for Hydrogen Sulfide, 0-200 ppm
M001-0057-000
UNI for Hydrogen Sulfide, 0-1,000 ppm
M001-0060-000
UNI for Oxygen, 0-25%
M001-0032-000
UNI for Oxygen, 0-30%
M001-0001-000
UNI for Sulfur Dioxide, 0-20 ppm
M001-0007-000
UNI for Chlorine, 0-50 ppm
M001-0004-000
UNI for Nitric Oxide, 0-250 ppm
M001-0015-000
UNI for Nitrogen Dioxide, 0-20 ppm
M001-0011-000
UNI for Hydrogen, 0-1,000 ppm
M001-0018-000
UNI for Hydrogen, 0-2,000 ppm
M001-0019-000
UNI for Phosphine, 0-20 ppm
M001-0016-000
UNI for Ethylene Oxide, 0-100 ppm
M001-0012-000
UNI for Ethylene Oxide, 0-200 ppm
M001-0069-000
UNI for Ammonia, 0-100 ppm M001-0006-000
UNI for Chlorine Dioxide, 0-1.00 ppm M001-0072-000
UNI for Hydrogen Cyanide, 0-100 ppm M001-0005-000
UNI for Ozone 0-1.00 ppm M001-0009-000
UNI for Hydrogen Fluoride, 0-10 ppm
M001-0014-000
UNI for Hydrogen Chloride, 0-15 ppm
M001-0008-000
UNI for Methyl Mercaptan
M001-0077-000
UNI for Tetrahydrothiophene, 0-50 ppm
M001-0085-000
UNI for Acetaldehyde, 0-20 ppm
M001-0080-000

UNI Single Gas Detector Literature

Tags: NH3 Ammonia Gas Detector,  CO Carbon Monoxide Gas Detector, Cl2 Chlorine Gas Detector, ClO2 Chlorine Dioxide Gas Detector, Ethylene Oxide Gas Detector, HCHO Formaldehyde Gas Detector, H2 Hydrogen Gas Detector, HCN Hydrogen Cyanide Gas Detector, H2S Hydrogen Sulfide Gas Detector, CH3-SH Methyl Mercaptan Gas Detector, NO Nitric Oxide Gas Detector, NO2 Nitrogen Dioxide Gas Detector, O2 Oxygen Gas Detector, PH3 Phosphine Gas Detector, SO2 Sulfur Dioxide Gas Detector

Product Enquiry