TS400 GfG Docking Station
Daily bump testing made simple with the TS400 GfG Docking Station for GfG G450 & G460 gas detectors.
For best pricing, please call 1-800-952-3293 or email sales@afcintl.com
Description
Daily bump testing made simple with the TS400 GfG Docking Station for GfG G450 & G460 gas detectors.
Features
- Fully automatic functional bump testing
- Automatic test of alarms, charging & record keeping
- Store bump test records for easy retrieval and report generation
- Up to 2,000,000 records in memory
- Economic use of test gas
- Simple pass/fail indication
- Saves time, gas and effort for lower cost of ownership
The operation of the TS400 bump testing station couldn’t be any easier. Simply put the G450 or G460 in the dock and the system will take over. The TS400 automatically performs a full functional test including a fresh air calibration, bump test, extensive sensor tests, alarm tests. The TS400 is designed to go beyond the traditional basic bump test and includes sensor diagnostics tests such as T50 and T90. After all, what good is a sensor that can respond to gas when it takes too long to get there? With the TS400 you can have confidence with this added level of safety.
The TS400 is available for use as a charger as well as a test station. After all tests have been completed you may remove and begin using the detector or leave it in the TS400 for recharging.
A good instrument gas detection maintenance program is not complete without equally good records keeping. Whether you choose to download or maintain the records on a PC or network or your preference is to leave it to the docking station, the TS400 is the right choice. The TS400 can retain as many as 2 million complete diagnostics in memory with maximum memory installed. That is over 50 years of data even if testing 100 detectors every single day.
The TS400 is designed to reduce the cost of ownership every step of the way. The push button regulator helps to sharply reduce the amount of gas required to test your instruments.
The TS400 comes complete with USB interface cable and download software. The SD card may also be downloaded using a standard SD card reader. The TS400 software includes a module to quickly print official bump test certificates. Simply download the records from the TS400 and start the Certificate Generator. The TS400 is available for use with the instrument only or there is an available design for use with the instrument with a pump. There is no need to remove the pump before placing the detector in the test station.
Specifications
Test Protocol | Gas Response: Automatic bump testing Response Time: T50 & T90 tests Alarm Activation: Time to activate alarm 1 & alarm 2 Visual Alarm: Automatic LED test Audible Alarm: Automatic horn test |
Interface | G450 or G460 keypad |
Display | G450 or G460 graphic display |
Time Stamp | Automatic/Real time clock |
Inlets | 1 gas and 1 fresh air |
Outlets | 1 gas exhaust |
Flow Rate | 0.5 LPM, variable flow |
Temperature Range | 50-90°F |
Power | 12 VDC wall cube, 12 VDC vehicle power (optional) |
Size | 3.5″ x 7″ x 6.3″ |
Weight | 10.5 ounces |
Warranty | 1 year |
Ordering Information
Each TS400 includes software, USB computer cable, tubing and manual. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description |
Catalog No.
|
TS400 Test Station, single cradle | 1450-601 |
TS400 Test Station, double cradle for instrument & pump | 1450-602 |
TS400 Test Station with Charging, single cradle | 1450-611 |
TS400 Test Station with Charging, double cradle for instrument & pump | 1450-612 |
Push Button Regulator, required, 0.5 LPM | 2603-400 |
Downloads
Related products
-
Honeywell BW Solo Single Gas Detector
Ships from the manufacturer, shipping times may vary
-
Clip Real Time Gas Detector for H2S, CO, O2 & SO2
Ships from the manufacturer, shipping times may vary
-
PS200 ABC Automatic Bump Test Station
Ships directly from the manufacturer, shipping times may vary.
-
DS400 GfG Docking Station
Ships from the manufacturer, shipping times may vary