Genuine Hydrogen Cyanide Replacement Sensor for QRae 3 gas detectors from Rae Systems by Honeywell.
All specifications have been verified under the following environmental conditions:
- Temperature: 68°F
- Relative Humidity (non-condensing): 50%
- Ambient Pressure: 1 atm (1,013 mbar)
Refer to the Technical Note TN-114 for a glossary of terms used on this page
Cross Sensitivities
Gas |
Concentration |
Response
|
Alcohols |
1,000 ppm |
0 ppm |
Carbon Dioxide |
5,000 ppm |
0 ppm |
Carbon Monoxide |
100 ppm |
0 ppm |
Hydrocarbons |
% range |
0 ppm |
Hydrogen |
10,000 ppm |
0 ppm |
Hydrogen Sulfide |
20 ppm |
0 ppm* |
Nitric Oxide |
10 ppm |
-5 ppm |
Nitrogen Dioxide |
10 ppm |
-7 ppm |
*Short gas exposure in minute range; after filter saturation; about 40ppm reading
Poisoning – Sensors are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided, both during storage, fitting in instruments and operation.
Downloads
Technical Note: TN-114 – Sensor Specifications and Cross Sensitivities for Hydrogen Cyanide Replacement Sensor
Disclaimer: Technical Note TN-114 presents specifications, cross sensitivities and calibration information on select Rae Systems by Honeywell sensors. All specifications presented in this Technical Note reflect the performance of standalone sensors. For instrument specifications, please refer to product datasheets and manuals. Actual sensor characteristics may differ when the sensor is installed in different instruments. As sensor performance may change over time, specifications provided are for brand new sensors.