You are here:

Combustible %LEL Replacement Sensor for AreaRae / MultiRae / ToxiRae Pro

Ships directly from the manufacturer, shipping times may vary.

$303.00

Description

Description

Genuine Combustible %LEL Replacement Sensor for AreaRae / MultiRae or ToxiRae Pro gas detectors from Rae Systems by Honeywell.

All specifications have been verified under the following environmental conditions:

  • Temperature: 68°F
  • Relative Humidity (non-condensing): 50%
  • Ambient Pressure: 1 atm (1,013 mbar)

Refer to the Technical Note TN-114 for a glossary of terms used on this page

Additional information

Weight .5 lbs

Specifications

Protected Catalytic Bead Electrochemical
Range 0-100%
Resolution 1% LEL
Drift <10% signal/month
Bias/Equilibration No Bias/10 minutes after installation
Storage Life 2 years in sealed container
Calibration Gas 50% LEL Methane or 2.5% by volume in Air
Operating Life 2 years in air
Temperature Range -4°F to 122°F
Storage Temperature Range 32°F to 68°F
Pressure Range Atmospheric ±20%
Operating Humidity 15 to 90% rH non-condensing
Warranty 2 years from date of shipment

Cross Sensitivities

Gas
LEL Relative Sensitivity1
LEL CF
Acetone
45
2.2
Ammonia 125 0.8
Benzene
40
2.5
Carbon Monoxide
83
1.2
Cyclohexane 40 2.5
Ethanol
59
1.7
Ethyl Acetate
45
2.2
Hydrogen 83 1.2
Isobutylene
67
1.5
Isopropanol
38
2.6
Leaded Gasoline 42 2.4
Methane
100
1
Methanol
67
1.5
Methyl Ethyl Ketone 38 2.6
n-Butane
63
1.6
n-Heptane
37
2.7
n-Hexane 40 2.5
n-Octane
34
2.9
n-Pentane
50
2
Phosphine 385 0.26
Propane
63
1.6
Propene
59
1.7
Toluene 33 3
Turpentine
34
2.9

1 – Response of the LEL sensors to a range of gases at the same LEL, expressed as percent of Methane response (=100). These figures are for guidance only and are rounded to the nearest 5%. For the most accurate measurements, the instrument should be calibrated with the gas under investigation.

Downloads

Technical Note: TN-114 – Sensor Specifications and Cross Sensitivities for Phosphine H Replacement Sensor

Disclaimer: Technical Note TN-114 presents specifications, cross sensitivities and calibration information on select Rae Systems by Honeywell sensors. All specifications presented in this Technical Note reflect the performance of standalone sensors. For instrument specifications, please refer to product datasheets and manuals. Actual sensor characteristics may differ when the sensor is installed in different instruments. As sensor performance may change over time, specifications provided are for brand new sensors.

Product Enquiry

Combined With Related Products

Customers Also Purchase

You may also like…