Description
Description
Genuine Combustible %LEL Replacement Sensor for AreaRae / MultiRae or ToxiRae Pro gas detectors from Rae Systems by Honeywell.
All specifications have been verified under the following environmental conditions:
- Temperature: 68°F
- Relative Humidity (non-condensing): 50%
- Ambient Pressure: 1 atm (1,013 mbar)
Refer to the Technical Note TN-114 for a glossary of terms used on this page
Cross Sensitivities
Gas |
LEL Relative Sensitivity1 |
LEL CF
|
Acetone |
45 |
2.2 |
Ammonia |
125 |
0.8 |
Benzene |
40 |
2.5 |
Carbon Monoxide |
83 |
1.2 |
Cyclohexane |
40 |
2.5 |
Ethanol |
59 |
1.7 |
Ethyl Acetate |
45 |
2.2 |
Hydrogen |
83 |
1.2 |
Isobutylene |
67 |
1.5 |
Isopropanol |
38 |
2.6 |
Leaded Gasoline |
42 |
2.4 |
Methane |
100 |
1 |
Methanol |
67 |
1.5 |
Methyl Ethyl Ketone |
38 |
2.6 |
n-Butane |
63 |
1.6 |
n-Heptane |
37 |
2.7 |
n-Hexane |
40 |
2.5 |
n-Octane |
34 |
2.9 |
n-Pentane |
50 |
2 |
Phosphine |
385 |
0.26 |
Propane |
63 |
1.6 |
Propene |
59 |
1.7 |
Toluene |
33 |
3 |
Turpentine |
34 |
2.9 |
1 – Response of the LEL sensors to a range of gases at the same LEL, expressed as percent of Methane response (=100). These figures are for guidance only and are rounded to the nearest 5%. For the most accurate measurements, the instrument should be calibrated with the gas under investigation.
Downloads
Technical Note: TN-114 – Sensor Specifications and Cross Sensitivities for Phosphine H Replacement Sensor
Disclaimer: Technical Note TN-114 presents specifications, cross sensitivities and calibration information on select Rae Systems by Honeywell sensors. All specifications presented in this Technical Note reflect the performance of standalone sensors. For instrument specifications, please refer to product datasheets and manuals. Actual sensor characteristics may differ when the sensor is installed in different instruments. As sensor performance may change over time, specifications provided are for brand new sensors.