Description
Description
2-Methoxyethyl Acetate Badge
- AKA – EGMEA, Methyl Cellosolve Acetate, Ethylene Glycol Monomethyl Ether Acetate; Glycol Monomethyl Ether Acetate
- CAS# – 110-49-6
- Analytical Method – OSHA 79, NIOSH 1451
- Absorbent – Activated Carbon
- Minimum Level of Quantitation – PPM for 8 Hours / PPM for 15 Minutes / PPM for 24 Hours
- Recommended Sampling Time – Workplace: 15 minutes to 8 hours / Indoor Air: 24 hours – 48 hours
- Interferences – No interferences are known
- Effect of Temperature – Less than 10% for each 10°C variation from 24°C
- Effect of Humidity – No effects detected at 30% RH to 92% RH
- Accuracy – Meets or exceeds OSHA accuracy requirements of +/- 25%
- Storage Conditions – Store at room temperature
- Recommended Holding Time – Monitors need to be returned to Lab within two weeks after sampling.