G200 Nitrous Oxide Monitor

The G200 is an advanced nitrous oxide monitor, N2O Analyzer. It uses a highly accurate non-dispersive IR cell providing superior stability and repeatability, with a measurement resolution of 1 ppm – full range.

Each unit includes battery charger, sample tube/filter, soda lime filter and hard sided case. The kit includes a hard sided case and soft sided case.

Ships from manufactuer-4 weeks delivery.

For best pricing, please call 1-800-952-3293 or email sales@afcintl.com

$5,689.00$5,999.00

Description

Description

The G200 is an advanced nitrous oxide monitor, N2O Analyzer. It uses a highly accurate non-dispersive IR cell providing superior stability and repeatability, with a measurement resolution of 1 ppm – full range. The range of the G200 is 0-1,000 ppm N2O. The G200 N2O analyzer is designed to safety check background and breathing zone levels of N2O (0-1,000ppm).

The rechargeable Li-Ion battery provides 8 to 10 hours of continuous operation with a low battery indicator. It provides an effective means of monitoring occupational exposure to nitrous oxide (N2O) in hospital operating rooms, dental offices, veterinary clinics and surgical care centers. The G200 can also be used to check for leaks in medical gas pipelines.

Viasensor has been acquired by QED Environmental Systems.

Additional information

Weight N/A

Features

  • Accurate verification of exposure limit breaches
  • Dual purpose background analyzer of personal analyzer
  • Leak detection for N2O storage
  • Portable
  • 0-1,000 ppm N2O, 0-10,000 in leak detection mode
  • TWA calculated
  • User settable alarms
  • Data download for graphing and reporting

Specifications

Range 0-1,000 ppm N2O
0-10,000 ppm (leak detection mode, indication only)
Resolution ±5 ppm for 0-100 ppm
±1.5% of range for 101ppm and above
Response Time T90≤40 seconds
Alarms Use selectable, TWA available
Communication USB type B mini-connector, HID device class
Data Storage 1,000 reaching set + 270 events
50 Site IDs and 300 sample point IDs
Flow 100 cc/min typically
Case ABS polycarbonate
Power Source Li-Ion
Battery Life 10 hours, 8 hours with pump
Charge Time 3 hours
Alternative Power USB connector, DC power supply
Operating Temperature 32-122ºF
Relative Humidity 5-95% non condensing
Dimensions 6.5″L x 4″W x 2.3″H
Weight 18 ounces
Warranty Instrument: 1 year
IR Cell: 2 years (excluding cell contamination)