Pac 8000 Single Gas Detectors from Draeger

Manufacturer:

This item is no longer available from AFC International, please contact us for suitable replacements.

With the robust Draeger Pac 8000 single gas detectors, you will be well equipped for tough conditions. This non-disposable, personal single gas detection device is a reliable and precise instrument, which detector hazardous conditions of twenty nine different gases, including special gases like Nitrogen Dioxide, Ozone and Phosgene.

You can count on the Pac 8000 to give you reliable, precise readings at any time even in extreme conditions. Out powerful sensors with a low T-90 response time ensure quick reactions. In addition to the standard alarms, you can define extra alarm thresholds for TLV and STEL.

The Draeger Pac 8000 performs especially well when detecting a variety of special gases. The Pac 8000 can be fitted with sensors for carbon dioxide, chlorine, hydrogen cyanide, ammonia, nitrogen dioxide, phosphine and organic vapors. Further demonstrating the capabilities of Draeger gas detectors is the the Draeger Pac 8000 performs especially well when detecting other gases as well. It can detect ozone from concentrations as low as 0.02 ppm and Phosgene from 0.01 ppm. The Pac 8000 detects Nitrogen Dioxide from concentrations as low as 0.04 ppm.

The Pac 8000 can easily handle even extreme conditions. The sensors can tolerate air pressures between 700 and 1,300 mBar. A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock proof, chemical resistant housing meets the requirements specified by the IP68 standard rating.

The D-Light indicates whether the functionality of the service has been tested and that it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Draeger Pac 8000 features clear, easily visible color coding, thereby minimizing the chance of mistakes.

The large display indicates the respective gas concentration. Other important information, such as the unit of concentration and battery capacity, is also displayed. The bright backlighting ensures that all values can be clearly read in the dark.

If the Draeger Pac 8000 measures hazardous gas concentrations, it sets off an audible, visual and noticeable vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic signal reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time. The Pac 8000 logs concentrations and events along with date and time. The data can be downloaded to a PC via an interface and processed further there.

The Pac 8000 logs concentrations and events along with date and time. The data can be downloaded to a PC via an interface and processed further there. The Pac 8000 is protected against, water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled in use, you can quickly and easily replace it yourself. The device is then ready to use again in no time

Sensor Specifications

Sensor
Range
Alarm A1
Alarm A2
Ozone (O3)
0-10 ppm
0.1 ppm
0.2 ppm
Chlorine (Cl2)
0-20 ppm
0.5 ppm
1.0 ppm
Hydrogen Cyanide (HCN)
0-50 ppm
2.5 ppm
4.5 ppm
Ammonia (NH3)
0-300 ppm
25 ppm
50 ppm
Nitrogen Dioxide (NO2)
0-50 ppm
2.5 ppm
5.0 ppm
Phosphine (PH3)
0-10 ppm
0.1 ppm
0.2 ppm
Carbon Dioxide
0-5.0 Vol%
0.5 Vol%
1 Vol%
Organic Vapor
0-200 ppm
10 ppm
20 ppm
Organic Vapor-A
0-200 ppm
10 ppm
20 ppm
Nitric Oxide (NO) 0-50 ppm 25 ppm 50 ppm
Phosphine
0-20 ppm
0.1 ppm
0.2 ppm

Specifications

Battery Service Life Minimum 2 years, Oxygen 12 months
Degree of Protection IP68
Temperature Range -22 to 131°F
Humidity 10 to 90% rH
Approvals CSA, IECEx, ATEX, CE
Size 2.5″ x 3.3″ x 1.0″
Weight 3.7 ounces

 