You are here:

Intrinsically Safe dBadge2 Noise Dosimeter

The dBadge2 has been designed specifically to be used in potentially explosive areas in the oil and gas, petrochemical and pharmaceutical industries as well as being suitable for use in the mining industry.

For best pricing, please call 1-800-952-3293 or email sales@afcintl.com

Description

Description


Intrinsically safe versions of the dBadge2 Noise Dosimeter are now available. The dBadge2 has been designed specifically to be used in potentially explosive areas in the oil and gas, petrochemical and pharmaceutical industries as well as being suitable for use in the mining industry. When Casella CEL introduced the revolutionary micro-sized dBadge cable-free, shoulder-mounted noise dosimeter to Industrial Hygienists and Safety professionals worldwide in 2006, it revolutionized personal noise exposure sampling in a significant way. Gone were all of the hassles and safety concerns of cable-mounted microphones – yet all the essential features of ‘traditional’ dosimeters (LCD data display, on-board control keys, IS approvals, ‘multiple metrics’ capture and secure data storage) were retained.

The dBadge2 has multiple simulated dosimeter capability to display noise exposure results according to differing regional or international protocols. Regardless of what you have displayed the dBadge2 always measures all parameters together. This helps ensure the correct parameters are always measured and you can choose how many parameters to display.

With it’s two button operation, the dBadge2 couldn’t be easier to use. After switching the dBadge2 on, apply the acoustic calibrator and press one button to perform calibration. Then hold both keys down to start a measurement. Each unit features lockable keys and display, automatic detection of acoustic calibrator, a color coded display and is easy to mount on the employees shoulder.

The dBadge2 is rated intrinsically safer for use in flammable atmospheres.

Different models of the dBadge2 are available with advanced functions depending on your requirements. Features available include audio notes at the start of a run to record measurement details, audio recording of level triggered events to identify anomalous noise, octave band analysis for selection of hearing protection and motion sensing to assist in measurement validation.

Features

  • Airwave software to check monitoring remotely
  • Multiple simulated dosimeters
  • Full color display
  • Motion sensing
  • 1 second time history profiling
  • Pause function
  • Measures all noise dose parameters simultaneously

Applications

  • Complete shift exposure measurements
  • Task based measurements
  • Measurements in accordance with CFR 1910-95, ISO9612:2009, L108 Controlling Noise at Work
  • Selection of hearing protection

Specifications

Acoustic Accuracy ANSI S1.25:1991, R2007, IEC 61252 Ed 1.1 (2002-3)
Dynamic Range 55.0-140.3 dB (A) RMS
Frequency Weightings A, C and Z, Type 2
Time Weightings Fast, Slow & Impluse
Exchange Rates (Q dB) Q=3 or Q=5B
Threshold Level (dB) Any levels from 70 to 90 in 1 dB steps
Criterion Level (dB) Any level between 70 and 90 in 1 dB steps
Real Time Clock Accuracy better than 1 minute per month
Under Range Indication 1 dB below the bottom of range
Overload Indication 140.4 dB RMS
Peak Overload Value 143.4 dB peak
Run Time Typically 35 hours using Broadband mode
Typically 15 hours using Octave mode
Charge Time < 6 hours from fully discharged
Storage Capacity Internal USD Flash memory – 300 hours of run data and up to 90 minutes of even audio recording
Battery Pack Internal NiMH, 800mAH
Bluetooth Range Typically 25M line of sight and depending on RF conditions
Display 96×64 dots full color OLED display with adjustable contrast
User Control 2 button operation, remote start/stop/pause using AirWave App
Stored Profile Values Lavg(Q=5), LZpk, Leq(Q=3), LCpk
PC Interface USB 2.0 full speed 12Mbps via docking station
Temperature Range 0°C – 40°C for <±0.5 dB error limit
Pressure Range <±0.5dB over 85-112kPa
Humidity Range <±0.5dB over 30%-90% non-condensing
Size 85mm L x 54mm W x 55mm H
Weight 117 g
Certifications ANSI S1.25:1991 R2007, IEC 61252 Ed 1.1 (2002-3)
Ex ia IIC T4 Ga, Ex ia IIIC T135°C Da, Ex ia I Ma

Ordering Information

All kits include the CEL-352 dBadge dosimeter(s) acoustic calibrator, charging base(s), universal power supply, USB cable, Insight database software and case. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Single Pack dBadge2 Noise Dosimeter Kit
dBadge2IS/K1
Twin Pack dBadge2 Noise Dosimeter Kit
dBadge2IS/K2
Five Pack dBadge2 Noise Dosimeter Kit dBadge2IS/K5
Ten Pack dBadge2 Dosimeter Kit dBadge2IS/K10
Single Pack dBadge2 Plus Noise Dosimeter Kit dBadge2PlusIS/K1
Two Pack dBadge2 Plus Noise Dosimeter Kit dBadge2PlusIS/K2
Five Pack dBadge2 Plus Noise Dosimeter Kit dBadge2PlusIS/K5
Ten Pack dBadge2 Plus Noise Dosimeter Kit dBadge2PlusIS/K10
Single dBadge2 Pro Noise Dosimeter Kit dBadge2ProIS/K1
Two Pack dBadge2 Pro Noise Dosimeter Kit dBadge2ProIS/K2
Five Pack dBadge2 Pro Noise Dosimeter Kit dBadge2ProIS/K5
Ten Pack dBadge2 Pro Noise Dosimeter Kit dBadge2ProIS/K10
Single dBadge2 Micro Noise Badge Unit with Mounting Clip and Windscreen dBadge2IS
Class 2 Acoustic Calibrator, 114 dB at 1 KHz CEL-120/2
3 Way Charger including PC18 Universal Power Supply 207078B/KIT
Charging Base Link Cable 20707B/EXT
Multi Pack Kit Case for 12 dBadge Dosimeters CEL-6355

Downloads

dBadge2 Sound Dosimeter Literature

Product Enquiry