Chip Measurement System (CMS) from Draeger

The Draeger Draeger Chip Measurement System is ready for use after only a brief instruction. It makes no difference which gas or vapor you wish to measure – the instrument is used in the same way every time. The operation is guided by a menu on the display and a single button/switch. The display can be backlit. After an automatic system self-test, the analyzer is powered up and the measurement system is immediately ready for operation.

The Draeger Draeger Chip Measurement System is ready for use after only a brief instruction. It makes no difference which gas or vapor you wish to measure – the instrument is used in the same way every time. The operation is guided by a menu on the display and a single button/switch. The display can be backlit. After an automatic system self-test, the analyzer is powered up and the measurement system is immediately ready for operation. Simply insert the chip, perform the measurement and read the measurement result displayed as a concentration on the screen. At the end of the measurement, the chip is automatically ejected from the instrument, and the analyzer shuts down. An audible signal sounds after each operating step. Power is supplied by 4 standard and easily replaceable batteries which are especially suited to the analyzer’s requirement. The battery capacity allows for more then 7 hours of measurement and is display on the screen.

The principle of mass current measurement ensures that the instrument remains unaffected by fluctuations in air pressure. Because the chips are calibrated before leaving the factory, there is no need for the user to calibrate the Chip Measurement System. Any possible temperature and humidity effects are checked during factory calibration. The analyzer is explosion protected and certified in accordance with UL, UL/CAS and Cenelec. In addition, the system is protected against dust and splash water in accordance with IP54 and is resistant to electromagnetic waves.

To allow measurement at places which are difficult to access, a remote system is available. This comprises of an additional pump and extension hose is is connected to the back of the analyzer. Because the remote system is activated by its own switch, the system can remain attached to the analyzer. A telescopic probe can also be attached to the remote system.

A kit for emergency response is now available. It includes an analyzer, remote system, telescopic probe, 10 chips, flashlight/lantern, notepad and a chip case. Note: Chips marked with a (*) are included with this kit.

Specifications

Measurement & Resolution Depends on chip type used
Typical Measurement Time 30 seconds to 5 minutes in range of the limit values, depends on chip type and concentration of hazardous substance
Temperature, Operation 32-104°F
Humidity 0-95%
System Diagnosis Automatic with micro controller for all system components
Display LCD, alphanumeric with backlighting
Operating Time About 45 minutes
Power Supply 4 x 1.5V alkaline batteries
Protection Class IP54
Weight 26 ounces
Dimensions 8.5″ x 4″ x 2.5″
Approvals  UL: Class 1 Div 1, Groups A, B, C, D, Temp Code T4, 2P91

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
CMS Analyzer Set, includes analyzer, allen wrench and batteries
6405300
CMS Analyzer Set with Remote System includes pump, 3M extension hose with adapter, float probe, screwdriver, allen wrench & batteries
8317700
Remote System for measurement of inaccessible place, includes 3M of hose with adapter, screwdriver & float probe
6405060
CMS Emergency Response Kit includes analyzer, remote system, telescopic probe, 10 chips (*) and carrying case
4055711
CMS Emergency Response Kit without Chips, includes analyzer, remote systems, telescopic probe and carrying case
4055976
CMS Indoor Air Quality Kit, includes analyzer, batteries, nylon transport case and 1 each of Carbon Dioxide, Carbon Monoxide, Formaldehyde and Ozone Chips
4056455
Telescopic Probe with FKM Sampling Hose, remote system required
8316530
CMS Sampling Hose with Adapter and Float Probe, remote system required, 3M
8317614
CMS Sampling Hose with Adapter and Float Probe, remote systems required, 10M 8317613
CMS Extension Hose Adapter
8319269
Training Chip
6406290
Soft Side Case for analyzer and chips
4594631
Molded Plastic Transport Case
4056442
CMS Emergency Response Case with foam inserts, holds 14-16 chips
4055979
CMS Handbook
9092086
CMS Training CD
4056637

Ordering Information – Chips

Chip
Measuring Range
Catalog No.
Acetic Acid
2.0-50.0 ppm
6406330
Acetone
40.0-600 ppm
6406470
Ammonia
0.20-5.0 ppm
6406550
Ammonia
2.0-50.0 ppm
6406130
Ammonia*
10.0-150 ppm
6406020
Ammonia
100-2,000 ppm
Benzene
50 – 2,500 ppb
6406600†
Benzene(**)*
0.20-10.0 ppm
6406030†
Benzene(**)
0.50-10.0 ppm
6406160†
Benzene
10.0-250 ppm
6406280
Butadiene
1.0-25.0 ppm
6406460
Carbon Dioxide
200-3,000 ppm
6406190
Carbon Dioxide*
1,000-25,000 ppm
6406070
Carbon Dioxide
1.0-20% vol
6406210
Carbon Monoxide*
5.0-150 ppm
6406080
Chlorine*
0.20-10.0 ppm
6406010
Ethanol
100-2,500 ppm
6406370
Ethylene Oxide
0.40-5.0 ppm
6406580
Formaldehyde
0.20-5.0 ppm
6406540
Hydrochloric Acid*
1.0-25.0 ppm
6406090
Hydrochloric Acid
20.0-500 ppm
6406140
Hydrogen Cyanide††
2.0-50.0 ppm
6406100
Hydrogen Peroxide††
0.20-2.0 ppm
6406440
Hydrogen Sulfide
0.20-5.0 ppm
6406520
Hydrogen Sulfide*
2.0-50.0 ppm
6406050
Hydrogen Sulfide
20.0-500 ppm
6406150
Hydrogen Sulfide
100-2,500 ppm
6406220
Iso-Propanol
40.0-1,000 ppm
6406390
Mercaptan
0.25-6.0 ppm
6406360
Methanol
20.0-500 ppm
6406380
MTBE
10.0-200 ppm
6406530
Methylene Chloride††
20.0-400 ppm
6406510
Nitrogen Dioxide*
0.50-25.0 ppm
6406120
Nitrous Fumes*
0.50-15.0 ppm
6406060
Nitrous Fumes
10.0-200 ppm
6406240
Oxygen
1.0-30.0% Vol
6406490
Ozone††
25.0-1,000 ppb
6406430
Perchloroethylene*††
5.0-500 ppm
6406040
Petroleum Hydrocarbons
20.0-500 ppm
6406200
Petroleum Hydrocarbons
100-3,000 ppm
6406270
Phosgene
0.05-2.0 ppm
6406340
Phosphine
0.10-2.5 ppm
6406400
Phosphine
1.0-25.0 ppm
6406410
Phosphine
20.0-500 ppm
6406420
Phosphine
200-5,000 ppm
6406500
Propane
100-2,000 ppm
6406310
Styrene
2.0-40.0 ppm
6406560
Sulfur Dioxide
0.40-10.0 ppm
6406110
Sulfur Dioxide
5.0-150 ppm
6406180
Toluene
10.0-300 ppm
6406250†
Training Chip
6406290
Trichloroethylene††
5.0-100 ppm
6406320
Vinyl Chloride
0.30-10.0 ppm
6406170
Vinyl Chloride
10.0-250 ppm
6406230
Water Vapor
0.40-10.0 mg/L
6406450
Xylene
10.0-300 ppm
6406260†

†Chips with cold storage requirement; to be stored at or below 50°F, do not freeze.

††Chips with a 6-12 month shelf life.

(**)Please Note: The two Benzene chips in the CMS program have nearly the same measurement range. The primary difference is the humidity limits. The Benzene 0.5-10 ppm chip is designed for high humidity environments. Please refer to the following table.

Maximum Humidity,
Benzene 0.2-10 ppm
Temperature °F
Maximum Humidity, Benzene 0.5-10 ppm
100%
32
100%
100%
50
100%
100%
68
100%
99%
86
100%
76%
95
100%
60%
104
80%

Performance Data

Measuring Range & Resolution Depends on the chip type
Typical Measuring Time 1-2 minutes in the range of the limit values, dependent on the chip type and the concentration of the hazardous substance
Contamination Effects Not possible
Calibration Not necessary
Operational Temperature 34 to 104°F (0 to 40°C)
Storage Temperature; Analyzer -4 to 140°F (-20 to 60°C)
Storage Temperature; Chips <77°F (<25°C)
Atmospheric Pressure 700 to 1,100 HpA (or Mbar)
Humidity 0 to 95% relative, not condensed
Determination of the Measurement Value Optics & light transfer system reflective measurement
System Diagnostics Self-performing, microprocessor controlled for all components of the system
Display LCD, 2 x 16 alphanumeric digits with backlight
Menu Languages English, German, French, Spanish
Operational Capacity Approximately 450 minutes on one set of batteries
Power Source 4 x 1.5V (AA) alkaline batteries
Weight 1.6 pounds (730g)
Dimensions 8″ x 3.6″ x 1.7″
Approvals UL Class 1, Div. 1, Groups A, B, C, D, Temp Code T4
Protection Class Dust & water spray protection according to IP54