You are here:

Sensit Gold 100 4 Gas Leak Detector for Measuring 0-100% Gas Volume

A portable leak detector and multi gas confined space monitor with expanded in field capabilities, the Sensit Gold 100 detector pinpoints natural gas or propane gas leaks and is designed to provide personal protection from potentially hazardous conditions.

For best pricing call 800-952-3293 or email at sales@afcintl.com

Description

The Sensit Gold 100 is a portable gas leak detector and multi gas confined space monitor with expanded in field capabilities. This detector pinpoints natural gas or propane gas leaks and is designed to provide personal protection from potentially hazardous conditions. The Sensit Gold 100 portable gas detector is designed to provide personal protection from potentially hazardous conditions and helps find the source of combustible gases fast. Whether you need an investigation tool or a confined space monitor, you can depend on the Sensit Gold 100 to provide the safety and accuracy you need.

Features

  • Highly sensitive leak detection
  • Measure from  LEL up to 100% gas volume, optional ppm scale
  • Selectable propane or natural gas scale
  • Display up to 4 gases: LEL, optional ppm & % volume, Oxygen, Carbon Monoxide, Hydrogen Sulfide
  • Internal pump & water/dust filters
  • Infrared downloading
  • Lowest cost, long life sensors
  • LED warning lights
  • Bright backlit LCD display with date and time display
  • Optional air free CO test
  • Field Calibration, calibration alert and calibration memory
  • Programmable auto shut off
  • Intrinsically safe

Applications

  • Combustible gas leak detection
  • Gas leak survey
  • underground leak pinpointing
  • Carbon monoxide monitoring
  • Combustible gas measurements
  • Pipeline purging (NFPA 54 Compliant)
  • Method 21 emissions testing
  • Inert gas operations

Specifications – Instrument

Battery Alkaline batteries, 12 hours continuous use
Approvals Class I, Div I, Groups C&D, Hazardous Location T4 with alkaline batteries
Size 3.0″ x 11.5″ x 2.32″
Weight 1.2 pounds

Specifications – Sensors

Type
Resolution
Range
Leak
N/A
10-50,000 ppm
PPM*
1 or 10 ppm
0-2,000 ppm
LEL
0.1%
0-100%
% Natural Gas
0.1%
5-100%
Oxygen
0.1%
0-25%
CO
1 ppm
0-2,000 ppm
H2S
1 ppm
0-100 ppm
HCN* 1 ppm 0-30 ppm

*Optional

Ordering Information

Each gas leak detector unit includes the instrument case, manual, sensor cap with replacement “O” rings, wrist strap and batteries. The compliance kit also includes calibration gas, regulator, bump test gas and adapter and case. Add (-K) to the catalog numbers below for the compliance kit. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
Sensit Gold, LEL % Vol only
910-FC100-A
Sensit Gold, LEL % Vol, & Carbon Monoxide
910-FC100-B
Sensit Gold, LEL % Vol ,& Oxygen
910-FC100-C
Sensit Gold, LEL  % Vol, & Hydrogen Sulfide
910-FC100-D
Sensit Gold, LEL % Vol, Carbon Monoxide & Oxygen
910-FC100-E
Sensit Gold, LEL % Vol,  Carbon Monoxide & Hydrogen Sulfide
910-FC100-F
Sensit Gold, LEL % Vol,  Oxygen & Hydrogen Sulfide
910-FC100-G
Sensit Gold, LEL % VOl,  Oxygen, Carbon Monoxide & Hydrogen Sulfide
910-FC100-H
Auto Log Memory
870-00002
ppm Display
870-00003
32″ Fiberglass Probe
883-00019
IR Link with SmartLink Software 870-00039
Hot Air Probe for Flue Gas Testing
883-00023
10′ Confined Space Entry Probe with Filter
883-00015

Downloads

Sensit Gold 100 literature

Product Enquiry