Draeger Inc.


Detectors by Draeger Safety

Draeger is a leading international company in the fields of medical and safety technology. Their innovative products, services and systems protect, support and save lives. People from hospitals, manufacturing, mining, fire protection and emergency services have trusted in Draeger since 1889. Besides striving for the highest quality and common interfaces between our products, Draeger also focuses on the protection of our environment and our natural resources.

4
Yes
None
1
60
Search...
/gas-detection-instruments/gas-detectors/by-manufacturer/draeger-inc/
Thumbnail
Sort By:

Categories:

Tags:

Manufacturer:

Model:

Short Description:

' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series D12 gas transmitter product line has been expanded. Now available in this versatile package is an LEL transmitter utilizing an Infrared sensor that resists the poisoning problems inherent in catalytic bead sensors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series PQ45 is the answer to the need for a rugged field deployed package capable of measuring and recording water quality data in a variety of operating environments.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Allegro's Air Filtration Panels convert shop air used for pneumatic tools and equipment to clean breathable air.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Area monitoring reinvented. That's what Draeger's X-zone 5500 brings to a worksite: a safer, more effective way to monitor for hazardous gases. In combination with the Draeger X-am 5000, 5100 or 5600 gas detection instruments, the X-zone 5500 can be used for the measurement of up to six gases and extends the range of your portable gas detection technology.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Breathe cool, stay safe: Draeger X-plore 1750 and 1760 is Draeger's new generation particle filtering face piece respirators, coming with distinct improvements in comfort and protection.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Combining versatility, ease of use and the latest breathing apparatus design, Draeger's PAS Micro is among the most technologically advanced, short duration emergency escape units available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Draeger's PAS Colt combines versatility, ease of use and the latest in breathing apparatus design. It is among the most technologically advanced, short duration emergency escape unit available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ER2000 Escape Respirator is a hood style full face respirator that provides respiratory protection from Nuclear, Biological and Chemical (NBC) warfare agents as well as Toxic Industrial Materials (TIM's).

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

FMC 2000 is a multi-channel controller with built in modem designed for integration with Rae Systems' wireless mesh network products. It is simple to install and operate, versatile, and dependable.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

For qualitative fit testing of air purifying respirators this Smoke Test Kit offers everything needed for meeting OSHA's protocol for fit testing with smoke.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Perfect for storing APR's cartridges and other respirator accessories such as fit testing kits, storage bags and cleaning supplies.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' Hand pump if for use with Rae's line of gas detection tubes.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' MultiRae Lite is a perfect wireless monitoring solution for personal protection. It can monitor up to six gases and thrives in confined space entry situations. This tool comes in either with an internal pump or diffusion monitor and is compatible with more than 30 sensor options allowing it to fully meet the monitoring requirements of any application.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' large selection of colorimetric gas detection tubes offer quick, on the spot measurements of a wide range of toxic and combustible gases and vapors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' ppbRae 3000 is a state of the art VOC gas detector for monitoring at the parts per billion (ppb) level. This device uses a new generation of photo ionization detector (PID) and features both temperature and humidity compensation for improved accuracy. It includes built in correction factors for over 200 compounds and is suitable for use in any hazardous environment.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Casella dBadge2 Noise Dosimeter keeps all the great attributes of the original dBadge but adds incredible features you won't want to do without!

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Draeger single cartridge system keeps cartridges and filters out of the wearer's line of vision without sacrificing service life or breathing comfort. the threaded adapter on the cartridges makes change out simple, quick and sure.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The GfG G460 combustible gas detector is the world's most advanced multi-sensor atmospheric monitor. The durable G460 continuously measures and displays readings for up to six gases at the same time.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae 2000 is no longer available. The MiniRae 3000+ has replaced the MiniRae 2000. The MiniRae 3000+ is Rae Systems most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae Lite from Rae Systems is the most reliable handheld portable volatile organic compound (VOC) monitor on the market. Its photo ionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for application ranging from environmental to construction.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Rae Systems MultiRae Pro is the industry's first wireless multi threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs), toxic, combustible gases and oxygen with Man Down Alarm functionality in one highly portable instrument.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The ToxiRae Pro is the world's first wireless personal monitor for toxic gases and oxygen. The Rae Systems ToxiRae Pro takes worker protection to the next level by providing safety professionals wireless access to real time instrument readings and alarm status (including man down alarm) from any location for better visibility and faster response.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The use of ozone gas is increasing rapidly in a wide variety of applications, such as water treatment, odor control and food processing. ATI's Model A23-14 is a portable generator designed to produce an ozone gas concentration below 1 ppm.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This Point of Attachment (POA) Air Control System connects to any breathing air source. It's housed in a Pelican carry case that can be wall mounted and includes an adjustable pressure regulator, pressure gauge and a pressure relief valve.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This heat stress meter features bright multi-color LCD backlights corresponding to OSHA's heat stress alert levels.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This unique sound meter enables remote sound level readings using a detachable probe. It features an RS232 computer interface, AC output and a coiled probe that extends to 9'.

' class='jquery-prod-cf-value' />
Aerotest Simultan Alpha for Measuring Grade D in Breathing Air

The quality of breathing air can be tested by this 4 gas detector in accordance to air purity standards according to ANSI specifications by means of quantitative measurements of the contaminants. Aerotest Simultan Alpha is suited for simultaneously examining the quality of air supplied by low pressure compressor or air supply lines. (50-300 psi)

Testing for CO, CO2, Oil and water content can be completed in as little as 5 minutes. The 4 gas detector can be connected to the low pressure compressed air supply systems via a barbed nipple connection. All components of the Aerotest Simultan Alpha are arranged in a carrying case and are ready to use.

Specifications

Medium Compressed air
Supply Pressure 50 psig to 300 psig
Connection Barbed nipple with ¼” NPT quick disconnect adapter
Flow 0.2 LPM & 4.0 LPM

Measuring Range

Tube
Measuring Range
Carbon Monoxide
5-50 ppm
Carbon Dioxide
100-3,000 ppm
Oil 0.1-10 mg/m3
Oil Impactor
0.1, 0.5, 1.0 mg/m3
Water Vapor
20-1,500 mg/m3

Ordering Information

Each Aerotest Simultan Alpha Kit, includes a deluxe carrying case, instructions, measuring device for tubes, quick-connect coupling and pressure reducer, deluxe tube opener, timer, oil impactor and impactor adapter and the tubes listed below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Aerotest Simultan Alpha Kit
6527150
Carbon Dioxide 100/a-P Tubes
6728521
Carbon Monoxide 5/a-P
6728511
Oil Impactor, pk/10 8103560
Oil 10/a-P 6728371
Water Vapor 20/a-P
8103061

Downloads

International Breathing Air Standards for Compressed A

Oil 10/a-P Tube Test Times datasheet

Oil Tube Detection limits datasheet

Dew point conversion table

Oil Tube Color Standard

Air Current Kit from Draeger Safety
The Draeger Air Current Kit is useful for the detection of air current to estimate their source, direction and speed. In some areas the detection of air current is of particular importance. Slight air currents must become visible to estimate their source, direction and speed. This is necessary
  • In mining for monitoring of firedamp in inaccessible places
  • In industry for the detection of leaks in pipelines, of air currents in rooms or for combustion plants and in laboratory stacks
  • In ventilation for control and setting up of air conditioning plants
In addition to this measurement, air currents are also helpful when estimating the distribution of toxic substances at workplaces. The knowledge of the air flow pattern permits objective selection of the right measuring points for any air analysis. The Draeger Air Current Kit consists of a porous carrier impregnated with fuming sulfuric acid. After opening the tube tips the air is pumped through the tube with the help of a rubber bulb. The white smoke emerging from the tube is carried along by the air flow and makes its direction visible. The air flow tester can be used repeatedly until smoke is finally exhausted. It the test is completed before the tube is exhausted, the tube should be sealed with the rubber caps provided.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
Air Current Kit includes carrying case, smoke tubes, tube opener, aspirator bulb, rubber caps, instructions & SDS sheet
CH00216
Smoke Tubes, pk/10
CH25301
Rubber Caps, pk/10 CH16631
Aspirator Bulb 4054382
Bump Test Station for Draeger Gas Detectors

This test is important in order to check the ability of the gas to flow through the dust and water filter over the sensor; to check that the calibration of the sensor is still correct; to check that the alarms work and are set correctly; to be in line with the regulations, standards, or recommendations from the local authorities.

A Draeger gas calibration cylinder is connected to the station. The bump test station includes the necessary gas regulator and an instrument-specific adapter for the connection of the different instruments.

Testing an instrument with a known concentration of gas is the only way to guarantee the reliable and accurate detection of gas hazards. During this test, the sensor’s response and the proper function of the instrument’s alarm functions will be checked.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Smart Bump Test Station with Printer Set for X-am 7000, without gas cylinder
8321009
Bump Test Station for X-am 3000 without gas cylinder
8317425
Bump Test Station for X-am 1000/2000/5000 without gas cylinder
8319131
Chip Measurement System (CMS) from Draeger

The Draeger CMS is ready for use after only a brief instruction. It makes no difference which gas or vapor you wish to measure – the instrument is used in the same way every time. The operation is guided by a menu on the display and a single button/switch. The display can be backlit. After an automatic system self-test, the analyzer is powered up and the measurement system is immediately ready for operation. Simply insert the chip, perform the measurement and read the measurement result displayed as a concentration on the screen. At the end of the measurement, the chip is automatically ejected from the instrument, and the analyzer shuts down. An audible signal sounds after each operating step. Power is supplied by 4 standard and easily replaceable batteries which are especially suited to the analyzer’s requirement. The battery capacity allows for more then 7 hours of measurement and is display on the screen.

The principle of mass current measurement ensures that the instrument remains unaffected by fluctuations in air pressure. Because the chips are calibrated before leaving the factory, there is no need for the user to calibrate the CMS. Any possible temperature and humidity effects are checked during factory calibration. The analyzer is explosion protected and certified in accordance with UL, UL/CAS and Cenelec. In addition, the system is protected against dust and splash water in accordance with IP54 and is resistant to electromagnetic waves.

To allow measurement at places which are difficult to access, a remote system is available. This comprises of an additional pump and extension hose is is connected to the back of the analyzer. Because the remote system is activated by its own switch, the system can remain attached to the analyzer. A telescopic probe can also be attached to the remote system.

A kit for emergency response is now available. It includes an analyzer, remote system, telescopic probe, 10 chips, flashlight/lantern, notepad and a chip case. Note: Chips marked with a (*) are included with this kit.

Specifications

Measurement & Resolution Depends on chip type used
Typical Measurement Time 30 seconds to 5 minutes in range of the limit values, depends on chip type and concentration of hazardous substance
Temperature, Operation 32-104°F
Humidity 0-95%
System Diagnosis Automatic with micro controller for all system components
Display LCD, alphanumeric with backlighting
Operating Time About 45 minutes
Power Supply 4 x 1.5V alkaline batteries
Protection Class IP54
Weight 26 ounces
Dimensions 8.5″ x 4″ x 2.5″
Approvals  UL: Class 1 Div 1, Groups A, B, C, D, Temp Code T4, 2P91

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
CMS Analyzer Set, includes analyzer, allen wrench and batteries
6405300
CMS Analyzer Set with Remote System includes pump, 3M extension hose with adapter, float probe, screwdriver, allen wrench & batteries
8317700
Remote System for measurement of inaccessible place, includes 3M of hose with adapter, screwdriver & float probe
6405060
CMS Emergency Response Kit includes analyzer, remote system, telescopic probe, 10 chips (*) and carrying case
4055711
CMS Emergency Response Kit without Chips, includes analyzer, remote systems, telescopic probe and carrying case
4055976
CMS Indoor Air Quality Kit, includes analyzer, batteries, nylon transport case and 1 each of Carbon Dioxide, Carbon Monoxide, Formaldehyde and Ozone Chips
4056455
Telescopic Probe with FKM Sampling Hose, remote system required
8316530
CMS Sampling Hose with Adapter and Float Probe, remote system required, 3M
8317614
CMS Sampling Hose with Adapter and Float Probe, remote systems required, 10M 8317613
CMS Extension Hose Adapter
8319269
Training Chip
6406290
Soft Side Case for analyzer and chips
4594631
Molded Plastic Transport Case
4056442
CMS Emergency Response Case with foam inserts, holds 14-16 chips
4055979
CMS Handbook
9092086
CMS Training CD
4056637

Ordering Information – Chips

Chip
Measuring Range
Catalog No.
Acetic Acid
2.0-50.0 ppm
6406330
Acetone
40.0-600 ppm
6406470
Ammonia
0.20-5.0 ppm
6406550
Ammonia
2.0-50.0 ppm
6406130
Ammonia*
10.0-150 ppm
6406020
Ammonia
100-2,000 ppm
Benzene
50 – 2,500 ppb
6406600†
Benzene(**)*
0.20-10.0 ppm
6406030†
Benzene(**)
0.50-10.0 ppm
6406160†
Benzene
10.0-250 ppm
6406280
Butadiene
1.0-25.0 ppm
6406460
Carbon Dioxide
200-3,000 ppm
6406190
Carbon Dioxide*
1,000-25,000 ppm
6406070
Carbon Dioxide
1.0-20% vol
6406210
Carbon Monoxide*
5.0-150 ppm
6406080
Chlorine*
0.20-10.0 ppm
6406010
Ethanol
100-2,500 ppm
6406370
Ethylene Oxide
0.40-5.0 ppm
6406580
Formaldehyde
0.20-5.0 ppm
6406540
Hydrochloric Acid*
1.0-25.0 ppm
6406090
Hydrochloric Acid
20.0-500 ppm
6406140
Hydrogen Cyanide††
2.0-50.0 ppm
6406100
Hydrogen Peroxide††
0.20-2.0 ppm
6406440
Hydrogen Sulfide
0.20-5.0 ppm
6406520
Hydrogen Sulfide*
2.0-50.0 ppm
6406050
Hydrogen Sulfide
20.0-500 ppm
6406150
Hydrogen Sulfide
100-2,500 ppm
6406220
Iso-Propanol
40.0-1,000 ppm
6406390
Mercaptan
0.25-6.0 ppm
6406360
Methanol
20.0-500 ppm
6406380
MTBE
10.0-200 ppm
6406530
Methylene Chloride††
20.0-400 ppm
6406510
Nitrogen Dioxide*
0.50-25.0 ppm
6406120
Nitrous Fumes*
0.50-15.0 ppm
6406060
Nitrous Fumes
10.0-200 ppm
6406240
Oxygen
1.0-30.0% Vol
6406490
Ozone††
25.0-1,000 ppb
6406430
Perchloroethylene*††
5.0-500 ppm
6406040
Petroleum Hydrocarbons
20.0-500 ppm
6406200
Petroleum Hydrocarbons
100-3,000 ppm
6406270
Phosgene
0.05-2.0 ppm
6406340
Phosphine
0.10-2.5 ppm
6406400
Phosphine
1.0-25.0 ppm
6406410
Phosphine
20.0-500 ppm
6406420
Phosphine
200-5,000 ppm
6406500
Propane
100-2,000 ppm
6406310
Styrene
2.0-40.0 ppm
6406560
Sulfur Dioxide
0.40-10.0 ppm
6406110
Sulfur Dioxide
5.0-150 ppm
6406180
Toluene
10.0-300 ppm
6406250†
Training Chip
6406290
Trichloroethylene††
5.0-100 ppm
6406320
Vinyl Chloride
0.30-10.0 ppm
6406170
Vinyl Chloride
10.0-250 ppm
6406230
Water Vapor
0.40-10.0 mg/L
6406450
Xylene
10.0-300 ppm
6406260†

†Chips with cold storage requirement; to be stored at or below 50°F, do not freeze.

††Chips with a 6-12 month shelf life.

(**)Please Note: The two Benzene chips in the CMS program have nearly the same measurement range. The primary difference is the humidity limits. The Benzene 0.5-10 ppm chip is designed for high humidity environments. Please refer to the following table.

Maximum Humidity,
Benzene 0.2-10 ppm
Temperature °F
Maximum Humidity, Benzene 0.5-10 ppm
100%
32
100%
100%
50
100%
100%
68
100%
99%
86
100%
76%
95
100%
60%
104
80%

Performance Data

Measuring Range & Resolution Depends on the chip type
Typical Measuring Time 1-2 minutes in the range of the limit values, dependent on the chip type and the concentration of the hazardous substance
Contamination Effects Not possible
Calibration Not necessary
Operational Temperature 34 to 104°F (0 to 40°C)
Storage Temperature; Analyzer -4 to 140°F (-20 to 60°C)
Storage Temperature; Chips <77°F (<25°C)
Atmospheric Pressure 700 to 1,100 HpA (or Mbar)
Humidity 0 to 95% relative, not condensed
Determination of the Measurement Value Optics & light transfer system reflective measurement
System Diagnostics Self-performing, microprocessor controlled for all components of the system
Display LCD, 2 x 16 alphanumeric digits with backlight
Menu Languages English, German, French, Spanish
Operational Capacity Approximately 450 minutes on one set of batteries
Power Source 4 x 1.5V (AA) alkaline batteries
Weight 1.6 pounds (730g)
Dimensions 8″ x 3.6″ x 1.7″
Approvals UL Class 1, Div. 1, Groups A, B, C, D, Temp Code T4
Protection Class Dust & water spray protection according to IP54
Civil Defense Simultaneous Tube Kits

The Draeger CDS civil defense set utilizes colorimetric Draeger detector tubes, the same tube chemistry used by NATO for many years in single tube detectors. Are you prepared to respond to a terrorist attack involving chemical weapons? In today’s world, immediate and accurate detection of toxic chemical agents is crucial. Draeger has developed an important detection system not available from any other manufacturer – specialized sets that detect up to five different chemical agents simultaneously – in just 5 minutes.

The Draeger CDS Kit provides two CDS sets for detection of eight chemical substances, including nerve, blood, lung, nose and throat irritating agents. And, the complete CDS Kit is much less expensive than the typical $15,000 cost of spectroscopic devices.

Features/Benefits

  • Low cost compared to spectroscopic devices
  • No power supply required for manual pump
  • On the spot results in five minutes
  • No warm up time
  • No calibration
  • Minimal training
  • Simple operation
  • No filters to replace

Ordering Information, Single Sets

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Simultaneous Test CDS Set I includes Hydrocyanic Acid, Phosgene, Lewisite, N-Mustard & S-Mustard
8103140
Simultaneous Test CDS Set V includes Nerve Agent, Phosgene, Cyanogen Chloride, Chlorine, S-Mustard
8103200
CDS Training Set for Simultaneous Test Set I
8103230
CDS Training Set for Simultaneous Test Set V
8103240
Set Opener
6400095
CDS Laminated Matrix Card
4056371
Brief Instruction Flip Cards for CDS Set I 4057230
Brief Instruction Flip Cards for CDS Set V 4057231
Accuro Pump
6400000
Adapter with 1 M Extension Hose for Accuro Pump
6400561
Adapter with 1 M Extension Hose for X-Act 5000
6400561
Tube Warmer
8316130
Hot Packs for Tube Warmer
8316139

Ordering Information

Description
Catalog No.
CDS Kit for Domestic Preparedness, includes 5 each of CDS Set I, 5 each of CDS Set V, 2 each of Accuro Hand Pumps, 2 each of Simultest Extension Hoses, 2 each of Simultest Set Openers, Spare Parts Kit, Instructions and Case
4523130
CDS/HazMat Kit includes 3 each of CDS Set I, 3 each of CDS Set V, 3 Hazmat Simultest Set I, 3 each of HazMat Simultest II, 3 each of HazMat Simultest III, 2 Accuro Hand Pump, 2 each of Sumultest Set Extension Hoses, 2 each Simultest Set Openers, Spare Parts Kit, Instructions and Case
4000050
CDS Kit with X-Act 5000 includes 5 each of CDS Set I & V, Accuro Pump, 2 Extension Hoses for Simultaneous Test Sets, 2 Simultest Set Openers, Spare Parts Kit, X-act 5000 with NiMH Battery & Charger, X-act 5000 Alkaline Battery Pack, Instruction flip Card Set for Set I & V and Carrying Case  4000040
CDS/HazMat Kit with X-act 5000 includes 3 each of CDS Set I & V, Hazmat Simultest Test I, Set, II & Set III, Accuro Pump, Spare Parts Kit, 2 Extension Hoses, 2 Simultest Set Openers, X-act 5000 with NiMH Battery & Charger, X-act 5000 Alkaline Battery Pack, Instruction Flip Card for CDS Set I & V, Laminated Instruction Cards and Case  4000030

Downloads

Civil Defense literature
Technical information on the CDS kits

Clandestine Lab Investigation Kits from Draeger Safety

Various hazardous gases can be generated by clandestine drug manufacturing laboratories. The physiological effects of these gases can vary from mild irritation, choking, severe nausea or rendering investigating personnel unconscious. The Draeger Clandestine Lab Investigation Kit (CLIK) is a quick, simple and accurate method for detecting these toxic agents.

The Draeger Tube system consists of the hand held accuro sample pump that draws air through the glass detector tube. If the chemical agent is present, the Draeger Tube changes color. Higher concentrations of gas produce a longer length of color change. A graduated scale printed on the tube indicates gas concentrations.

The one handed operation of the accuro pump allows the other hand to be free for maneuvering into position or handling a weapon. The Draeger CLIK measure Ammonia, Phosphine and Hydrochloric Acid. Draeger tubes are available for measuring many other gases which be present in clandestine labs.

Ordering Information

The CLIK contains an accuro pump, tube opener, ammonia detector tubes, phosphine detector tubes, hydrochloric acid/nitric acid detector tubes, rigid carrying case, spare parts kit, allen wrench, and rubber caps. The Clan Lab Simultest Kit includes an accuro pump, simultest extension hose, simultest set opener, instructions, 5 Clan Lab Simultest Sets, instructions and case. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Clandestine Lab Investigation Kit
4520407
Clan Lab Simultest Kit
4056562

Accessory Ordering Information

Description
Catalog No.
3 Meter Extension Hose with Adapter
6400077
10 Meter Extension Hose with Adapter
6400078
15 Meter Extension Hose with Adapter
6400079
Ammonia Tubes
CH20501
Hydrochloric/Nitric Acid Tube
8101681
Phosphine Tubes
8103711
Clan Lab Simultest Set
8103310
Tube Warmer
8316130
Hot-Packs for Tube Warmer, pk/2 8316139
Molded Plastic Transport Case 4056442
Simultest Extension Hose for Accuro
6400561
Simultest Set Opener
6400095
Clan Lab Simultest Laminated Instruction Card
4056564

Downloads

Information about the Clan Lab Simultest Kit including instruments for use

Diffusion (Passive Sampling) Tubes from Draeger Safety

Draeger Diffusion Tubes are direct reading, scaled tube that can be used for determining time weighted average concentrations (TWA). The Draeger Diffusion Tubes are direct reading, scaled tubes that can be used for determining time weighted average concentrations. The tubes work by passive gaseous diffusion and can be used over a period of 8 hours or longer in some cases.

Designed as a personal monitor, the diffusion tubes also can be used for area monitoring. The diffusion tubes are used with an ultralight plastic reusable holder which attached to clothing and protects the tube during use. The time weighted average can be calculated at any time during the measurement by simply dividing the length of the tube reading by the elapsed sampling time (in hours).

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Draeger Tube
Range in Absolute Units
(ppm x h)
Range of Measurement for Maximum Period of Use
(8 hrs)
Catalog No.
Acetic Acid 10/a-D
10-200
1.3-25 ppm
8101071
Ammonia 20/a-D
20-1,500
2.5-188 ppm
8101301
Butadiene 10/a-D
10-300
1.3-38 ppm
8101161
Carbon Dioxide 500/a-D
500-20,000
65-2,500 ppm
8101381
Carbon Dioxide 1%/a-D
1-30 Vol% x h
0.13-3.8 Vol %
8101051
Carbon Monoxide 50/a-D
50-600
6.3-75 ppm
6733191
Ethanol 1000/a-D
1,000-25,000
125-3,100 ppm
8101151
Hydrochloric Acid 10/a-D
10-200
1.3-25 ppm
6733111
Hydrocyanic Acid 20/a-D
20-200
2.5-25 ppm
6733221
Hydrogen Sulfide 10/a-D
10-300
1.3-38 ppm
6733091
Nitrogen Dioxide 10/a-D
10-200
1.3-25 ppm
8101111
Perchloroethylene 200/a-D
200-1,500
25-188 ppm
8101401
Sulfur Dioxide 5/a-D
5-150
0.6-19 ppm
8101091
Toluene 100/a-D
100-3,000
13-380 ppm
8101421
Trichloroethylene 200/a-D
200-1,000
25-125 ppm
8101441
Tube Holder
Pk of 3
6733014
Draeger Comfort Vest Cooling Vest
When work gets hot, the Draeger Comfort Vest CVP 5200 is always ready to use because it delivers the cooling action itself. This means no pre-freezing, no dipping into water, no risk due to dangerous circulating air and no time loss. The Draeger Comfort Vest helps to absorb excess body heat and offers comfort for the wearer when working in high temperature surroundings or performing tasks that are physical enough to cause excessive sweating. It will also rehabilitate after working in hot climates. The vest’s cooling action is derived from 20 individual PCM-elements (Phase Change Material) integrated into the inner lining. When the user’s skin temperature reaches 82°F, whether performing tasks that are physical enough to cause sweating or working in high temperature surroundings, the content of the PCM-elements gradually becomes liquid by absorbing the excessive heat. This reduces skin temperature by approximately 5-7°F. Depending on the level of physical work and the ambient temperature, the cooling benefit for the wearer of the Draeger Comfort Vest can last up to four hours. When the vest is stored at a temperature below 72°F, the cooling elements will regenerate within 30 minutes to 4 hours, depending on the ambient temperature. The cooler the temperature, the sooner the vest will be ready to be worn again. Extensive preparatory and post-work activities – as with ice vests – are no longer necessary. The arrangement of the PCM-elements provides high freedom of movement thanks to the flexible fit. The vest can be worn underneath protective clothing such as turnout gear, coveralls or gas-tight chemical protective suits. Broad Velcro fasteners ensure a tight fit.

Features

  • Service life of the PCM-elements: up to 3 years
  • Easy donning thanks to Velcro fasteners
  • Vest can be washed after the elements have been removed
  • Available in 4 sizes: S/M, L/XL, XXL/XXXL, XXXXL/XXXXXL

Specifications

Skin Temperature Difference 5-7°F
Deployment Time About 1.5 – 4 hours
Cooling Surface About 2.37 ft3
Material, Vest Polyester
Material, Cooling Elements Salt crystal mixture, packed in polyester/polyamide
Color Inside: black Outside: blue
PCM-Elements 20 pieces
Restoration Time of Cooling Elements At 68°F: About 4 hours At 46°F: About 30 minutes
Storage Condition Horizontal
Storage Temperature < 72°F
Weight 4.63 pounds

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Comfort Vest CVP 5220, S/M includes 20 large and 2 small PCM-elements R58762
Comfort Vest CVP 5220, L/XL includes 20 large and 2 small PCM-elements R58763
Comfort Vest CVP 5220, XXL/XXXL includes 20 large and 2 small PCM-elements R58764
Comfort Vest CVP 5220, XXXXL/XXXXXL includes 20 large and 2 small PCM-elements R58761
PCM-Element, Large R45104
Transporations Bag, Blue R53373

Downloads

Comfort Vest CVP 5200 literature
Draeger Safety X-am 2500 with Datalogger Multi Gas Detector
Draeger Safety’s X-am 2500 Multi Gas Detector accurately detects flammable gases, oxygen, carbon monoxide, nitrogen dioxide, sulfur dioxide and hydrogen sulfide and is the only 1-4 gas monitor that you need in industrial, mining and refinery applications. The X-am 2500 combines reliable sensor technology with long battery life and intuitive operation in an instrument that defines safety. The X-am 2500 has a large, easy to read, liquid crystal display. All gas readings are shown simultaneously and resize automatically depending on the number of sensors installed. When a gas alarm occurs, the reading for the sensor in alarm will be highlighted and will alternate with the alarm level indication of A1 or A2. The Draeger X-am 2500 can operate for more than 12 hours with either alkaline batteries or with rechargeable NiMH batteries. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without an Ex sensor installed is typically more than 250 hours. The X-am 2500 is compatible with Draeger’s X-dock testing and calibration station. X-dock is Draeger’s solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump test in 8 to 15 seconds with more than 40% less gas consumption than competitive instruments. The X-am 2500 is also compatible with the Draeger Bump Test Station. The innovative, Catalytic Ex sensor has a high degree of drift stability with a high resistance to silicone and hydrogen sulfide. The sensor boasts an expected service life of more than 5 years and is extremely sensitive to flammable gases and vapors. Further, the X-am 2500 is approved for measuring, according to IEC/EN 60079029-1, from methane to nonene. The Draeger X-am 2500 has Ex approval for zone 0 for user safety in areas subject to explosion hazard. Additionally, it is not sensitive to electromagnetic radiation, e.g. from wireless devices and is water and dust resistant in accordance with protection class IP67. An optional external pump with a hose up to 98 feet is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws. The Draeger X-am 2500 portable gas detector is comfortably worn thanks to its low weight and ergonomic design and gas can enter the unit from above and from the front – even if the instrument is inside a pocket or if the front gas entry is accidentally covered. The practical two button control panel and easy menu navigation allow for intuitive operation while the integrated protective rubber coating and sensors not sensitive to shock provide additional safety in case of impacts or vibrations. The X-am 2500 can store the highest gas readings for the Ex and toxic gas sensors and the lowest reading for the oxygen sensor. These readings can be easily reset after a gas exposure without having to turn the monitor off and on.

Instrument Specifications

Battery NiMH: >12 hours Alkaline: >12 hours Alkaline without EX Sensor: >500 hours
Alarms Visual: 360° Audible: Multi tone >90 dB at 30 cm Vibration
Temperature -4 to 122°F
Pressure 700 to 1300 mbar, 20.7 to 38.4″ Hg
Humidity 10 to 95% Rh
IP Protection IP 67
Charging Time < 4 hours
Data Logger Can be read out via IR > 1,000 hours with 4 sensors and a recording interval of 1 reading per minute
Size 1.85″ x 5.12″ x 1.73″
Weight 9 ounces
Approvals UL: Class 1, Div 1, Groups A, B, C & D, Temp Code T4/T3 ATEX: II 2G EEx ia d IIC T4/T3; I M2 EEx ia d I, CSA: Class I, Div 1, Groups A, B, C & D, Class II, E, F, G, Temp Code T4/T3, IECEx: Ex ia d I/IIC T4/T3 CE Mark: Electromagnetic compatibility MSHA
Warranty 3 years on monitor and sensors, 2 years on optional T4 NiMH battery pack

Sensor Specifications

Gas
Range
Resolution
Combustible
0-100% LEL
1% LEL
Carbon Monoxide (CO)
0-2,000 ppm
2 ppm
Hydrogen Sulfide-LC (H2S)
0-100 ppm
0.1 ppm
Oxygen (O2)
0-25 Vol %
0.1% Vol
Nitrogen Dioxide (NO2) 0-50 ppm 0.1 ppm
Sulfur Dioxide (SO2) 0-100 ppm 0.1 ppm

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
X-am 2500 Gas Detector, add sensors below 8323900
Combustible Sensors, 0-100% LEL 6812950
Carbon Monoxide Sensor, 0-2000 ppm 6813210
Hydrogen Sulfide Sensor, 0-100 ppm 6811525
Nitrogen Dioxide Sensor, 0-50 ppm 6810884
Oxygen Sensor 0-25% Vol 6810881
Sulfur Dioxide Sensor, 0-100 ppm 6810885
NiMH Battery & Charger Kit 8318785

Accessory Ordering Information

Description
Catalog No.
Pump Kit includes USB charger, wall plug and shoulder strap
8327115
Confined Space Entry Set includes USB Cable, wall plug, 5M hose, float probe and shoulder strap
8327117
Dust/Water Stop filter for Remote Sampling Pump 4543759
Hand Pump Kit with 10 feet of Tygon Tubing 4594585
Water Trap, Dust/Mist Filter for Hand Pump 4523078
NiMH Battery Kit includes battery, charge cradle & power supply
8318785
NiMH Battery Pack 8318704
GasVision Software for data download & management
8325646
CC-Vision software for calibration & configuration Free
Telescopic Probe, 4.5′
4510546
Telescopic Probe, 6.5′
4510545
Calibration Adapter 8318752
Sample Probe Replacement Filter, 3 Hydrophobic & 10 Particulate 4511290
Float Probe, order hose separately 6802337
Tygon Sampling Hose, 10′ 4594501
Teflon-Lined Sampling Hose, 5′ 4594112
Bump Test Station w/o gas 8319131
Protective Rubber Boot 8321506
Deluxe Instrument Case 4543755
Deluxe Instrument/Pump Case 4543935
Nylon Transport Case
4594631
50% LEL CH4, 100 ppm CO, 25ppm H2S, 17% Vol O2 Calibration Gas 4594655
USB-IR Communication Cable 8317409

Downloads

X-am 2500 multi gas detector literature
Draeger Safety X-am 5000 Multi Gas Detector

The Draeger Safety X-am 5000 is smallest combustible gas detection instrument for up to 5 gases. The Draeger X-am 5000 belongs to a new generation of gas detectors, developed specifically for personal monitoring as well as oxygen and harmful concentrations of CO, H2S, CO2, Cl2, HCN, NH3, NO2, PH3, H2, NO and SO2. Two new sensors are available including the Dual O2/CO and the dual H2S/CO. Despite its advanced functionality, the Draeger X-am 5000’s practical, mobile phone design and light weight make it comfortable for users to carry. Reduced to its essentials, the two button control panel and easy to follow menu system allow for intuitive use.

It is easy to exchange, upgrade or calibrate the sensors to other gases. The ability to customize the X-am 5000’s sensors makes more application possible.

For improved safety when facing unknown and potentially explosive hazards – the x-am 5000 provides dependable warnings in the event of explosive atmospheres due to the high level of sensitivity of the innovative catalytic ex sensor. It not only responds quickly to explosive gases and combustible organic vapors, it is also highly resistant against sensor poisons such as silicone and hydrogen sulfide. In combination with its long term stability, this offers a long sensor lifetime of over 4 years. This will reduce operational costs.

Equipped with durable XXS sensor technology, the x-am 5000 offers maximum security at extremely low operational costs. The x-am 5000 is water and dust resistant, accordingly to IP67 standards. The detector remains fully functional and ready to use, even after being dropped into water. The integrated rubber protection and shock proof sensors provide additional resistance to impact and vibration. Moreover, the X-am 5000 is resistant to electromagnectic interference.

The optional external pump, which operates with a hose length of up to 45M makes it possible to use the detector for pre-entry measurements into confined spaces such as tanks, shafts, etc. The pumps tarts automatically when attached to the detector.

Simple, fast and professional; from function or bump test to complete documentation, users can choose from a range of practical, on-site solutions that offer maximum safety for every application. The automatic test and calibration station, X-Dock, and the Draeger Bump Test Station are ideal system extensions that save time and reduce workload. Fresh air, mixed gas and single gas calibrations can be done directly using the x-am menu.

The X-am 5000 can be used with standard alkaline batteries. In addition, it can be fitted with a T4 battery that can be charged while still inside the instrument. The optional Save Energy Mode makes it possible to increase the operating time of the X-am 5000 to more than 40 hours. This i done by selecting a measurement interval of either one second , 10 or 20 seconds for the CatEx sensor.

Instrument Specifications

Battery Alkaline, rechargeable NiMH cells for alkaline pack, T4 battery pack
Alarms Visual: 360°
Audible: multi tone >90 dB at 1 foot
Vibration
Temperature -4 to 122°F, intermittent + 130°F
Pressure 700 to 1300 hPa, 20.7 to 38.4″ Hg
Humidity 10 to 95% Rh
Datalogger Can be read via infrared about 1000 hours with 5 gases and a recording interval of 1 reading per minute
Operating Time Alkaline or NiMHJ: >12 hours
NiMH HC, without Ex Sensor: >13 hours
Alkaline Battery with Energy Saving Mode: >40 hours
Charging Time <4 hours
Size 1.85″ x 5.12″ x 1.73″
Pump Operation Maximum hose length 45 M, 30 hours with 3AA alkaline batteries
Weight 7.8 ounces
Approvals UL: Class I & II, Div 1, Groups A, B, C, D, E, F, G Temp Code T4/T3
IECEx: Ex ia I, Ex ia IIC T3, Ex d ia I, Ex d ia IIC T4/T3

Sensor Specifications

Gas
Range
Resolution
CO/H2S
CO: 0-2000 ppm
H2S: 0-100 ppm
CO: 1ppm
H2S: 0.1 ppm
Carbon Monoxide (CO)
0-2,000ppm
1 ppm
Hydrogen Sulfide (H2S)
0-200 ppm
1 ppm
Oxygen (O2)
0-25 Vol %
0.1 % Vol
Nitric Oxide (NO) 0-200 ppm 1 ppm
Nitrogen Dioxide (NO2) 0-50 ppm 0.1 ppm
Sulfur Dioxide (SO2) 0-50 ppm 0.1 ppm
Phosphine (PH3) 0-20 ppm 0.01 ppm
Phosphine High Range (PH3) 0-1,000 ppm 1 ppm
Hydrogen Cyanide (HCN) 0-50 ppm 1 ppm
Ammonia (NH3) 0-300 ppm 1 ppm
Carbon Dioxide (CO2) 0-5 Vol % 0.1 Vol %
Chlorine (Cl2) 0-10 ppm 0.01 ppm
Hydrogen (H2) 0-2,000 ppm 5 ppm
Hydrogen High Range (H2) 0-4 Vol % 0.01 Vol %
Organic Vapor 0-200 ppm 1 ppm
Organic Vapor-A 0-200 ppm 1 ppm
Amines 0-100 ppm 1 ppm
Mercaptan 0-40 ppm 1 ppm
Phosgene 0-10 ppm 0.01 ppm
Ozone (O3) 0-10 ppm 0.01 ppm
Dual O2/CO  O2: 0-25% Volume
CO: 0-2,000 ppm
 O2: 0.1%
CO: 1 ppm

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
X-am 5000 Gas Detector, please choose sensors below
8320000

Sensor Ordering Information

Description
Catalog No.
Cat Ex 125 Sensor, 0-100% LEL
6812950
Oxygen Sensor, 0-25% Vol
6810881
Carbon Monoxide Sensor, 0-2,000 ppm
6813210
Carbon Monoxide Sensor, H2 Compensated, 0-2,000 ppm 6811950
Hydrogen Sulfide Sensor, 0-200 ppm
6810883
Hydrogen Sulfide Sensor, high range, 0-1,000 ppm
6812015
Nitrogen Dioxide Sensor, 0-50 ppm
6810884
Sulfur Dioxide Sensor, 0-100 ppm
6810885
Phosphine Sensor, 0-20 ppm
6810886
Phosphine Sensor, high range, 0-2,000 ppm
6812020
Hydrogen Cyanide Sensor, 0-50 ppm
6810887
Ammonia Sensor, 0-300 ppm
6810888
Carbon Dioxide Sensor, 0-5.0n % Vol
6810889
Chlorine Sensor, 0-20  ppm
6810890
Organic Vapor Sensor, 0-200 ppm
6811530
Organic Vapor-A Sensor, 0-200 ppm
6811535
Hydrogen Sulfide Sensor LC, Low Concentration, 0-100 ppm
6811525
Carbon Monoxide/Hydrogen Sulfide Sensor, 0-2,000 ppm & 0-100 ppm
6813280
Hydrogen Cyanide Sensor, 0-50 ppm 6813165
Hydrogen Low Concentration Sensor, 0-2,000 ppm
6812370
Hydrogen High Concentration Sensor, 0-4% Vol
6812025
Nitric Oxide Sensor, 0-200 ppm
6811545
Amines Sensor, 0-100  ppm
6812545
Mercaptan Sensor, 0-40 ppm
6812535
Phosgene Sensor, 0-10 ppm
6812005
Oxygen Sensor Sensor, 5 year Warranty, 0-25 % Vol
6812211
Carbon Monoxide Sensor, 5 year Warranty, 0-2,000 ppm 6812212
Hydrogen Sulfide Sensor, 5 year Warranty, 0-200 ppm 6812213
Ozone Sensor, 0-10 ppm 6811540
Dual O2/CO Sensor, 0-2,000 ppm & 0-25% Vol 6813275
Carbon Monoxide Sensor, 0-10,000 ppm 6812010
Dual Carbon Monoxide/Hydrogen Sulfide Sensor, 0-2,000 ppm & 0-200 ppm 6811410
Dual H2S/Oxygen Sensor, 0-100 ppm & 0-25% Vol 6814137
Nitrogen Dioxide Sensor, 0-50 ppm 6812600
Oxygen Sensor, 0-100 % Vol 6812385

Accessory Ordering Information

Description
Catalog No.
Alkaline Battery Pack
8322237
NiMh Battery Pack
8318704
NiMh Battery & Charger Kit 8318785
Kit Pump with USB Charger, wall plug and shoulder strap 8327115
CSE Set includes Pump, USB Cable, wall plug, 5M hose, float probe, & shoulder strap 8327117
Rubber Boot
8321506
Leather Case with shoulder strap 88327104
GasVision Software for data download & management
8314034
IR Adapter 8317409
Telescopic Probe, 4.5′
4510546
Telescopic Probe, 6.5′
4510545
12″ Clear Plastic Sample Probe 4511262
Sample Probe Replacement Filter, 3 Hydrophobic & 10 Particulate 4511290
Float Probe with luer adapters and hose 8327654
Tygon Sampling Hose, 10′ 4594501
Teflon-Lined Sampling Hose, 5′ 4594118
Bump Test Station w/o gas 8319131
USB-IR Communication Cable 8317409
Deluxe Instrument Case 4543755
Deluxe Instrument/Pump Case 4543945
Nylon Transport Case
4594631

Downloads

X-am 5000 literature

Tags: Ammonia gas detector, Combustible gas detector, Carbon Monoxide gas detector, Hydrogen Sulfide gas detector, Oxygen gas detector, Nitric Oxide gas detector, Nitrogen Dioxide gas detector, Sulfur Dioxide gas detector, Carbon Dioxide gas detector, Chlorine gas detector

Draeger Safety X-am 7000 Combustible Gas Detector With PID
Draeger X-am 7000 multi  gas detector is an innovative solution for the simultaneous and continuous detection of up to five gases. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The Draeger X-am 7000 also has a photo-ionization detector (PID) that detects volatile organic compounds (VOC) for VOC monitoring and VOC gas detection.  A PID sensor is now available for the Draeger X-am 7000 combustible gas detector. This smart plug and play sensor is intended for use in confined space entry and area monitoring applications. The PID sensor can used in sample draw of diffusion configurations. This sensor employs a 10.6 eV lamp to monitor a wide range of VOC’s from 0 to 5,000 ppm depending on the gas selected with a 1 ppm resolution. Draeger X-am 7000 portable gas detector is an innovative solution for the simultaneous and continuous detection of up to five gases. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The Draeger X-am 7000 can be equipped with three electrochemical and two catalytic bead or infrared sensors. It is the ideal companion in a great number of application where reliable monitoring of oxygen, toxic and combustible gases and vapors in the ambient air is necessary. The extensive portfolio of over 25 different DraegerSensors allows the detection of more than 100 gases and vapors. The measuring range of the EC, Cat-EX and IR sensors can be changed to another gas within a list of gases by a push of a button – without the necessity of recalibrating. This way the accuracy and the range of the monitored substances is increased. DraegerSensors are renowned for fast response, minor cross sensitivities, high accuracy and long life. Each sensor is recognized automatically by the instrument. All sensors are precalibrated and a reconfiguration of the Draeger X-am 7000 is done by simply changing a sensor. No additional service or maintenance is necessary. The software menu of the Draeger X-am 7000 was designed in partnership with our customers making it simple and easy to use. With the help of CC-Vision software, up to 5 different detection applications can be saved within the instrument By doing so, the use of different instrument configurations can be set for that specific application. During operation, a simple change between these set parameters can be done via the instrument’s menu. A new, flexible goose-neck probe simplifies the search for leaks at e.g. flanges, shut-off devices and valves. In the tracking mode, the instrument generates an increasing or decreasing rate of beeps, depending on the gas concentration detected. Additional to the built in dust and splash water protection, the Draeger X-am 7000 can be submersed without damage. A specially designed rubber boot protects the instrument against damage from a drop of 5 feet. The completely new design of the rechargeable battery block with intelligent charging management guarantees full functionality of the instrument over a period of up to 20 hours (depending on the battery type). An alkaline battery pack is also available. The DraegerSensors used in the Draeger X-am 7000 have a typical life of over 5 years. If, in time, an exchange is necessary, the modular approach of the instrument allows this in a few simple steps. Alarm conditions can not be ignored because of the sound of an extremely loud multi tone horn. In addition the visual alarm can be seen through 360° ensuring it attracts the users attention. By generating an optional life signal every six seconds the Draeger X-am 7000 confirms it is functioning normally. The large graphic display and the alarm auto zoom function guarantee easy recognition of the values and symbols displayed for immediate judgment about the situation or hazards. All information is provided in plain text. A built in data memory logs up to 3,000 sets of values – that is data logging of 100 hours when recording one set per minute. The data can be transmitted and evaluated on a PC using an infrared interface together with the GasVision software package. The built in high power pump allows to sample gas through a 45M long tube. The operation of the pump is continuously monitored and the instrument will generate an alarm if the flow is too low.

Instrument Specifications

Battery NiMH (4.8V/3.0 Ah); >9 hours NiMH (4.8V/6.0 Ah): >20 hours Alkaline: >20 hours
Alarms Visual: 360º, flashing LEDs Audible: > 100 dB at 1 foot
Temperature -5 to 105°F, intermittent + 130°F
Pressure 700 to 1300 hPa, 20.7 to 38.4″ Hg
Humidity 10 to 95% Rh
Case IP 67
Charging Time 3.5 to 7 hours, depending on battery type
Pump Mode Maximum length of tubing 150′
Size 5.9″ x 5.6″ x 3″
Weight 21 ounces
Approvals UL: Class 1, Div 1, Groups A, B, C & D, Temp Code T4 ATEX: II 2G EEx ia d IIC T4; -25<Ta<55°C, I M2 EEx ia d I CSA: Class I, Div 1, Groups A, B, C & D, Temp Code T4 CE Mark: Electromagnetic compatibility

Sensor Specifications

Gas
Range
Catalog No.
CO XS 2
0-2,000 ppm
6810365
CO XS EC
0-2,000 ppm
6809105
CO XS R
0-2,000 ppm, 5 year
6810258
CO XS EC HC
0-10,000 ppm
6809120
H2S XS2 0-100 ppm 6810370
H2S XS 2 SR 0-100 ppm 6810575
H2S XS EC 100 0-100 ppm 6809110
H2S XS EC HC 0-1,000 ppm 6809180
H2S XS R 0-100 ppm, 5 year 6810260
Oxygen 0-25 Vol % 6810375
Oxygen XS EC 100 0-100 Vol % 6809550
Oxygen XS EC LS 0-25 Vol % 6809130
Oxygen XS R 0-25 Vol %, 5 year 6810262
Amine XS EC 0-100 ppm 6809545
Chlorine XS EC 0-20 ppm 6809165
ClO2 XS EC 0-20 ppm 6811360
CO2 XS EC 0-5 Vol % 6809175
Phosgene XS EC 0-3.00 ppm 6808582
Hydrogen XS EC 0-2,000 ppm 6809185
Hydrogen XS EC HC 0-4 Vol % 6811365
Hydrogen Cyanide 0-50 ppm 6809150
Hydride XS EC 0-20 ppm 6809135
Ammonia XS EC 0-300 ppm 6809145
Nitric Oxide XS EC 0-200 ppm 6809125
NO2 XS EC 0-50 ppm 6809155
Odorant XS EC 0-40 ppm 6809200
Organic Vapor XS EC 0-200 ppm 6809115
Organic Vapor-A XS EC 0-100 ppm 6809522
Phosphine XS EC HC 0-1,000 ppm 6809535
Sulfur Dioxide XS EC 0-100 ppm 6809160
Infrared EX 0-100 % LEL, 0-100 Vol % CH4 6810460
Infrared CO2 0-5% Vol/0-9,900 ppm 6810590
Infrared CO2 0-100% Vol/0-9,990 ppm 6810599
Cat EX HC PR 0-100% LEL/0-100% Vol, 2 year 6812970
Cat EX PR 0-100% LEL/0-5% Vol 6813980
CatEX FR PR 0-100 % LEL, 0-100% Vol, 1 year 6812975
PID 0-2,000 ppm 8319100

Ordering Information

Many X-am 7000 versions are available including an infrared hydrocarbon sensor and infrared carbon dioxide sensor. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com,

Downloads

Draeger X-am 7000 Literature Tags: Ammonia gas detector, Carbon Monoxide gas detector, Combustible gas detector, Hydrogen Sulfide gas detector, Oxygen gas detector, Amine gas detector, Chlorine  gas detector, Chlorine Dioxide gas detector, Carbon Dioxide  gas detector, Phosgene  gas detector, Hydrogen  gas detector, Hydrogen Cyanide gas detector, Nitric Oxide gas detector, Nitrogen Dioxide gas detector, Sulfur Dioxide gas detector
Draeger Safety X-Zone Wireless Area Monitor

The Draeger X-zone 5500 transforms the Draeger X-am 5000/5100/5600 personal gas detection instruments into innovative area monitoring devices for a wide range of applications. In addition to personal air monitors carried on the body, these area monitors are positioned where gas hazards are expected to increase the level of safety.

The illuminated green LED ring indicates that the air if free of toxic and combustible gases. Upon detection of gas hazards, the LED color changes from green to red, thus providing a clear visual warning that gas is present. Additionally, a loud and highly audible evacuation alarm is emitted. The Draeger X-zone 5500 gas entry is arranged that the gas can diffuse into Draeger X-am gas monitors from all sides.

Up to 25 Draeger X-zone 5500 units can be automatically interconnected to form an open wireless fenceline network. A closed network may be established for up to 16 X-zone 5500 units.The interconnection allows wide safety networks in larger areas. A Draeger X-zone 5500 detecting a gas alarm transmits the alarm signal to all interconnected units. A red flashing master alarm in the mother unit detecting gas contrasts with red/green flashing alarms of the connected daughter units providing simple recognition of alarm status and the actual location of the hazard.

An integrated pump version allows for continuous monitoring of confined spaces and locations which are difficult to access, even from a distance of up to 150 feet.

Features

  • 360° gas entry
  • Daily function test and calibration not required after single on-site testing
  • Individually configurable with the Draeger CC-Vision PC software
  • Inductive charging station: easy and convenient non-contact charging
  • Continuous operation for up to 120 hours

X-zone Specifications

Life Signal Green status display 360°, illuminated ring (LED)
Alarms Visual: 360° LED
Audible: 360°; >108 dB at 1M, 120 dB at 30 cm
Configurable alarm patterns, frequencies and volume
Temperature -20 to 50°C
Pressure 700 to 1,300 hPa
Humidity 10 to 95% Rh
Ingress Protection IP 67
Operating Time About 120 hours (24 Ah battery)
Dependent upon sensor & configuration of the life signal
Charging Time <14 hours
Flexible power supply: External 100-240V charger or inductive wireless charger
Pump Operation Maximum hose length is 45M
Alarm Output Potential free alarm, contact for intrinsically safe circuits (6-pole)
<20 V to 0.25A (0.15 constant current)
Resisting load
Radio Transmission Worldwide license free ISM frequencies, digital radio, robust and interference free transmission up to 100M
RF Approvals 915 MHz
Size 20″ x 12″ x 12″
Weight 22 pounds, 24 Ah battery
Approvals ATEX: I M1 Ex ia I MA, II 1G Ex ia IIC T3 Ga, II 2G Ex ia d IIC T4 GB
IEC: Ex ia IIC T3 Ga, Ex ia d IIC T4 Ga, Ex ia I Ma
CSAUL: Class I, Zone 0, AEX is IIC T3 Ga, Class I, Zone 1, AEx d ia IIC T4 Gb

X-am 5000 Instrument Specifications

Battery Alkaline, rechargeable NiMH cells for alkaline pack, T4 battery pack
Alarms Visual: 360°
Audible: multi tone >90 dB at 1 foot
Vibration
Temperature -4 to 122°F, intermittent + 130°F
Pressure 700 to 1300 hPa, 20.7 to 38.4″ Hg
Humidity 10 to 95% Rh
Datalogger Can be read via infrared about 1000 hours with 5 gases and a recording interval of 1 reading per minute
Operating Time >12 hours with pulsed mode > 40 hours
Charging Time <4 hours
Size 1.85″ x 5.08″ x 1.22″
Pump Operation Maximum hose length 20 M, 30 hours with 3AA alkaline batteries
Weight 7.8 ounces
Approvals UL: Class I & II, Div 1, Groups A, B, C, D, E, F, G Temp Code T4/T3
IECEx: Ex ia I, Ex ia IIC T3, Ex d ia I, Ex d ia IIC T4/T3
ATEX: I M1 Ex ia I, II 1G Ex ia IIC T3, I M2 Ex d ia I, II 2G Ex d ia IIC T4/T3
CSA: pending
CE Mark: Electromagnetic compatibility, 89/336/EWG
RoHS: Directive 2002/95/EC

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
X-zone 5500, Diffusion, 24 Ah Battery 8324823
X-zone 5500, Pump, 24 Ah Battery 8324825
Set Pin Block 8325323
Electrolube, 2ml 8324826
Plug in Charger, 100-240 VAC 8320749
Inductive Charger with Power Supply 8322076
Diffusion Cap, included with pumped versions 8323935
Pump Cap 8323936
X-Zone Connector Cap 1893632
Cap for X-am 5100, filters required 8323938
Filters for Cap used with X-am 5100, 5 pack 8323016
Alarm Damper 8320110
Leg Extender Stand 8320645
X-zone RS485 Cable 8321669
Hose Set with Filter (Water Trap, 10 cm FMK Tubing, Filter) 8321527

Downloads

X-zone 5500 literature

X-am 5000 literature

Draeger Saver CF N Emergency Escape Breathing Apparatus

In emergency situations, conditions can deteriorate rapidly. Ambient breathing air can be suddenly filled with smoke or toxic fumes and rapid escape is the only available option. The Saver C N constant flow emergency escape breathing apparatus (EEBA) allows safe, effective and uncomplicated escape from hazardous environments. Simple to don and easy to operate, this hood based, positive pressure breathing device can be used with minimal training. The Draeger Saver CF N is highly visible and was designed to be suitable even for people with spectacles or facial hair. When opened, the Draeger Saver is automatically activated and begins feeding a continuous supply of breathing air. The Save gives the wearer the precious additional time needed to exit the area safely.

Packaged in an integrated soft bag, the Saver can be easily wall mounted in strategic locations in potentially hazardous areas. The bright orange bags feature reflective panels for enhanced visibility even under low lighting conditions. The Saver is compact and lightweight and can be worn either as a chest bag or over the shoulder. Made from highly resistant materials, it is washable, flame retardant and allows water to drain freely.

The Draeger Save utilizes a simple, fail safe reducer system with excellent flow characteristics, providing a consistent rate of air flow until the cylinder is completely empty. It can be equipped with cylinder which can hold either a 5, 10 or 15 minute supply of air. The flame retardant hood incorporates a large visor for maximum peripheral vision.

The Draeger Saver requires very little service or maintenance. A transparent window on the soft bag lets you check the cylinder pressure gauge without unpacking the unit. The cylinder can be refilled without the need to remove it from the bag.

The Draeger Saver CF N  complies with NIOSH, ABS and TC approvals. It can be used in a range of applications both on and off shore to protect the user against any unexpected change in environment. Chemical, oil & gas, shipping steel and pharmaceutical industries can all rely on the Saver CF N for safe and uncomplicated escape.

Specifications

Cylinder Charging Pressure 3,000 psi
Airflow to the Hood 35-37 LPM
Operating Temperature -15°C to 60°C
Size 5 Minute: 240 x 180 x 320mm
10 Minute: 240 x 180 x 440mm
15 Minute: 240 x 190 x 420mm
Weight 5 Minute: 3.98 kg
10 Minute: 5.12 kg
15 Minute: 5.45 kg
Approvals NIOSH, ABS, TC

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description Catalog No.
Saver CF 5N, 5 Minute EEBA 4042055
Saver CF 10N, 10 Minute EEBA 4042056
Saver CF 15N, 15 Minute EEBA 4042057
Saver CF 5N Bag Assembly 3392381
Saver CF 10N Bag Assembly 3362393
Saver CF 15N Bag Assembly 3362405
Single Saver CF Case 3351823
Cylinder CF 15 (N) Assembly 4042060

Downloads

CF Saver Escape Respirator

Draeger Short Term Detector Tubes: A

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases and Vapors
Draeger Tube
Measuring Range

Catalog No.

Acetaldehyde Acetaldehyde 100/a
100-1,000 ppm
6726665
Acetic Acid Acetic Acid 5/a
5-80 ppm
6722101
Acetic Anhydride Formic Acid 1/a
1-15 ppm
6722701
Acetone Acetone 40/a (5)
40-800 ppm
8303381
Acetone 100/b
100-12,000 ppm
Acetylene Petroleum Hydrocarbons 100/a
100-2,500 ppm
6730201
Acid Compounds in Air Acid Test
Qualitative
8101121
Acrolein Dimethyl Sulfide 1/a (5)
1-15 ppm
6728451
Acrylonitrile Acrylonitrile 0.5/a (5)
0.5-20 ppm
6728591
Air Current Smoke Tube
CH25301
Alcohol Alcohol 100/a
100-3,000 ppm
CH29701
Aliphatic Hydrocarbons Hydrocarbon 2
2-23 mg/l
CH25401
Amine Test Amine Test
Qualitative
2-Aminoethanol Ammonia 0.25/a
0.25-3 ppm
8101711
2-Aminopropane Cyclohexylamine 2/a
2-30 ppm
6728931
Ammonia Ammonia 0.25/a
0.25-3 ppm
8101711
Ammonia 2/a
2-30 ppm
6733231
Ammonia 5/a
5-600 ppm
CH20501
Ammonia 5/b
2.5-100 ppm
8101941
Ammonia 0.5%/a
0.05-10 Vol %
CH31901
n-Amyl Acetate Ethyl Acetate 200/a
200-3,000 ppm
CH20201
Aniline Aniline 0.5/a
0.5-10 ppm
6733171
Aniline 5/a
1-20 ppm
CH20401
Antimony Hydride (Stibine) Arsine 0.05/a
0.05-60 ppm
CH25001
Arsine Arsine 0.05/a
0.05-60 ppm
CH25001
Aziridine Ammonia 0.25/a
0.25-3 ppm
8101711

*Aerosol tubes Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: B
A Draeger short term detector tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each short term detector tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Basic Compounds in Air Amine Test
Qualitative
8101061
Benzene Benzene 0.5/a
0.5-10 ppm
6728561
Benzene 0.5/c (specific) (5)
0.5-10 ppm
8101841
Benzene 2/a (5)
2-60 ppm
8101231
Benzene 5/b
5-50 ppm
6728071
Benzene 15/a
15-420 ppm
8101741
Benzyl Chloride Perchloroethylene 0.1/a
0.1-4 ppm
8101551
Bromine Chlorine 0.2/a
0.2-30 ppm
CH24301
Bromoethane Methyl Bromide 5/b
20-200 ppm
CH27301
1,3-Butadiene Chloroprene 5/a
1-60 ppm
6718901
n-Butane Hydrocarbons 0.1%/b
0.1-0.8 Vol%
CH26101
iso-Butane Hydrocarbons 0.1%/b
100-1,600 ppm
CH26101
2-Butanone (MEK) Acetone 100/b
100-12,000 ppm
CH22901
n-Butyl Acetate Ethyl Acetate 200/a
200-3,000 ppm
CH20201
sec-Butyl Acetate Acetaldehyde 100/a
100-1,000 ppm
6726665
tert-Butyl Acetate Acetaldehyde 100/a
50-300 ppm
6726665
n-Butylamine Cyclohexylamine 2/a
2-30 ppm
6728931
1-Butylene Olefins 0.05%/a
0.04-1.3 Vol %
CH31201
*Aerosol tubes Italic Font indicates SEI certification Boxes offering less than 10 tests are designated with the number of tubes in parentheses.
Draeger Short Term Detector Tubes: C

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

 

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Carbon Dioxide Carbon Dioxide 100/a
100-3,000 ppm
8101811
Carbon Dioxide 0.1%/a
0.1-6 Vol %
CH23501
Carbon Dioxide 0.5%/a
0.5-10 Vol %
CH31401
Carbon Dioxide 1%/a
1-20 Vol %
CH25101
Carbon Dioxide 5%/A
5-60 Vol %
CH20301
Carbon Disulfide Carbon Disulfide 3/a
3-95 ppm
8101891†
Carbon Disulfide 30/a 5-60 ppm 6728351
Carbon Disulfide 30/a
32-3,200 ppm
CH23201
Carbon Monoxide Carbon Monoxide 2/a
2-300 ppm
6733051
Carbon Monoxide 5/c
5-700 ppm
CH25601
Carbon Monoxide 8/a
8-150 ppm
CH19701
Carbon Monoxide 10/b
10-3,000 ppm
CH20601
Carbon Monoxide 0.3%/b
0.3-7 Vol %
CH29901†
Carbon Pretube Carbon Pretube
n/a
CH24101
Carbon Tetrachloride Carbon Tetrachloride 0.1/a
0.1-5 ppm
8103501
Carbon Tetrachloride 1/a (5)
1-50 ppm
8101021
Carbonyl Chloride Phosgene 0.02/a
0.02-1 ppm
8101521
Phosgene 0.25/b
0.25-15 ppm
CH28301
Chlorine Chlorine 0.3/b
0.3-10 ppm
6728411
Chlorine 0.2/a
0.2-30 ppm
CH24301
Chlorine 50/a
50-500 ppm
CH20701
Chlorine Dioxide Chlorine 0.2/a
0.1-1.5 ppm
CH24301
Chlorine Dioxide 0.025/a
0.025-1 ppm
8103491
Chlorobenzene Chlorobenzene 5/a (5)
5-200 ppm
6728761
2-Chloro-1,3-Butadiene Chloroprene 5/a
5-60 ppm
6718901
1-Chloro-2,3-Epoxypropane Epichlorohydrin 5/b
5-50 ppm
6728111
Chloroform Chloroform 2/a (5)
2-10 ppm
6728861†
Chloroformates Chloroformates 0.2/b
0.2-10 ppm
6718601
Chloropicrin Chloropicron 0.1/a
0.1-2 ppm
8103421
Chloroprene Chloroprene 5/a
5-60 ppm
6718901
Chromic Acid Chromic Acid 0.1/a* (9)
0.1-0.5 mg/m3
6728681
m-Cresol Phenol 1/b
0.8-16 ppm
8101641
o-Cresol & p-Cresol Phenol 1/b
Qualitative
8101641
Cumene Toluene 50/a
50-400 ppm
8101701
Cyanide Cyanide 2/a
2-15 mg/m3
6728791†
Cyanogen Chloride Cyanogen Chloride 0.25/a
0.25-5 ppm
CH19801
Cyclohexane Cyclohexane 40/a
40-3,000 ppm
8103671
Cyclohexylamine Cyclohexylamine 2/a
2-30 ppm
6728931

*Aerosol tubes Italic Font indicates SEI certification

†Tubes with 6 or 12 month shelf life.

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: D

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
DDVP Phosphoric Acid 0.05/a
0.05 ppm
6728461
Demeton Thioether
1 mg/m3
CH25803
1,2-Diaminoethane Ammonia 0.25/a
0.5-12 ppm
8101711
1,2-Dibromoethane Methyl Bromide 5/b
5-50 ppm
CH27301
o-Dichlorobenzene Chlorobenzene 5/a (5)
Qualitative
6728761
1,2-Dichloroethane Methyl Bromide 5/b
100-300 ppm
CH27301
Dichloromethane Methylene Chloride 100/a
10-2,000 ppm
6724601
1,2-Dichloropropane Methyl Bromide 5/b
50-100 ppm
CH27301
1,2-Dichloro-1,1,2,2-Tetrafluoroethane Halogenated Hydrocarbons 100/a (8)
200-2,800 ppm
8101601
Dichlorovos Phosphoric Acid Esters 0.05/a
0.05 ppm
6728461
Diesel Fuel Diesel Fuel 25-200 mg/m3
8103475†
Diethylamine Triethylamine 5/a
5-60 ppm
6718401
Diethylene Dioxide Ethyl Glycol Acetate 50/a
13-175 ppm
6726801
Diethyl Ether Diethyl Ether 100/a
100-4,000 ppm
6730501
Difluorochloromethane Halogenated Hydrocarbons 100/a (8)
200-2,800 ppm
8101601
Dimethyl Acetamide Dimethyl Formamide 10/b
100-400 ppm
6718501
Dimethylamine Triethylamine 5/a
5-60 ppm
6718401
Dimethylethylamine Triethylamine 5/a
5-60 ppm
6718401
Dimethyl Formamide Dimethyl Formamide 10/b
10-40 ppm
6718501
1,1-Dimethyl Hydrazine Hydrazine 0.25/a
0.1-10 ppm
CH31801
Dimethyl Sulfate Dimethyl Sulfate 0.005/c (9)
0.005-0.05 ppm
6718701
Dimethyl Sulfide Dimethyl Sulfide 1/a (5)
1-15 ppm
6728451
Dioxane Ethyl Glycol Acetate 50/a
13-175 ppm
6726801

*Aerosol tubes

†Tubes with 6 or 12 month shelf life.

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: E

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email  sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog. No.
Epichlorohydrin Epichlorohydrin 5/b
5-80 ppm
6728111
Ethanethiol Mercaptan 0.5/a
0.5-5 ppm
6728981
Mercaptan 20/a
20-100 ppm
8101871
Ethanol Alcohol 100/a
100-3,000 ppm
CH29701
Ethanolamine Ammonia 0.25/a
0.5-6 ppm
8101711
Ether Diethyl Ether 100/a
100-4,000 ppm
6730501
Ethyl Acetate Ethyl Acetate 200/a
200-3,000 ppm
CH20201
Ethyl Acrylate Methyl Acrylate 5/a
5-300 ppm
6728161
Ethyl Alcohol (Ethanol) Alcohol 100/a
100-3,000 ppm
CH29701
Ethylamine Triethylamine 5/a
5-60 ppm
6718401
Ethyl Benzene Ethyl Benzene 30/a
30-600 ppm
6728381
Ethyl Bromide Methyl Bromide 5/b
20-200 ppm
CH27301
Ethylene Ethylene 0.1/a (5)
0.1-5 ppm
8101331
Ethylene 50/a
50-2,500 ppm
6728051
Ethylene Bromide Methyl Bromide 5/b
5-50 ppm
CH27301
Ethylene Chloride Methyl Bromide 5/b
100-300 ppm
CH27301
Perchloroethylene 2/a
Qualitative
8101501
Ethylene Diamine Ammonia 0.25/a
0.5-12 ppm
8101711
Ethylene Glycol Ethylene Glycol 10 (5)
10-180 mg/m3
8101351
Ethylene Glycol Monoethyl Ether Ethyl Glycol Acetate 50/a
Qualitative
6726801
Ethylene Glycol Monoethyl Ether Acetate Ethyl Glycol Acetate 50/a
50-700 ppm
6726801
Ethylene Oxide Ethylene Oxide 1/a (5)
1-30 ppm
6728961
Ethylene Oxide 25/a
25-500 ppm
6728241
Ethyl Ether Diethyl Ether 100/a
100-4,000 ppm
6730501
Ethyl Formate Ethyl Formate 20/a
20-500 ppm
8103541
Ethyl Glycol Acetate Ethyl Glycol Acetate 50/a
50-700 ppm
6726801
Ethyl Mercaptan Mercaptan 0.5/a
0.5-5 ppm
6728981
Mercaptan 20/a
20-100 ppm
8101871

*Aerosol tubes

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: F

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Fluorine Fluorine 0.1/a
0.1-2 ppm
8101491
Fluorotrichloromethane Halogenated Hydrocarbons 100/a (8)
100-1,400 ppm
8101601
Formaldehyde Formaldehyde 0.2/a
0.2-5 ppm
6733081
Formaldehyde Activation Tube (use with above)
To extend measuring range to 0.04 ppm
8101141
Formaldehyde 2/a
2-40 ppm
8101751
Formic Acid Formic Acid 1/a
1-15 ppm
6722701

*Aerosol tubes

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: Gasoline

A tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Gasoline Petroleum Hydrocarbons 10/a
10-300 ppm
8101691
Petroleum Hydrocarbons 100/a
100-2,500 ppm
6730201

*Aerosol tubes

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: H

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Heptane Hexane 100/a
200-600 ppm
6728391
Hexane Hexane 10/a
10-2,500 ppm
8103681
Hexone (MIBK) Acetone 100/b
130-15,600 ppm
CH22901
Hydrazine Hydrazine 0.1/a
0.01-6 ppm
8103351
Hydrazine 0.25/a
0.1-10 ppm
CH31801
Hydrocarbons Hydrocarbons 0.1%/c Propane
0.1-1.3 Vol % Propane
8103581
Hydrocarbon 2/a
3-24 mg/l
8103581
Petroleum Hydrocarbons 10/a
10-300 ppm n-Octane
8101691
Petroleum Hydrocarbons 100/a
100-2,500 ppm n-Octane
6730201
Hydrochloric Acid Hydrochloric Acid 1/a
0.5-100 ppm
CH29501
Hydrochloric Acid 50/a
50-5,000 ppm
6728181
Hydrochloric Acid/Nitric Acid 1/a
1-10 ppm HCl1-15 ppm HNO3
8101681
Hydrochlorice Acid 0.2/a
0.2-20 ppm
8103481
Hydrocyanic Acid Hydrocyanic Acid 2/a
0.5-100 ppm
8103601
Hydrogen Hydrogen 0.2%/a
0.2-2 Vol%
8101511
Hydrogen Chloride Hydrochloric Acid 1/a
1-10 ppm
CH29501
Hydrochloric Acid 50/a
50-5,000 ppm
6728181
Hydrochloric Acid/Nitric Acid 1/a
1-10 ppm HCl1-15 ppm HNO3
8101681
Hydrogen Cyanide Hydrocyanic Acid 2/a
2-150 ppm
CH25701
Hydrogen Fluoride Hydrogen Fluoride 0.5/a
0.5-90 ppm
8103251
Hydrogen Fluoride 1.5/b
1.5-15 ppm
CH30301
Hydrogen Peroxide Hydrogen Peroxide 0.1/a
0.1-3 ppm
8101041
Hydrogen Sulfide Hydrogen Sulfide 0.2/a
0.2-5 ppm
8101461
Hydrogen Sulfide 0.2/b
0.2-6 ppm
8101991
Hydrogen Sulfide 0.5/a
0.5-150 ppm
6728041
Hydrogen Sulfide 1/d
1-200 ppm
8101831
Hydrogen Sulfide 2/a
2-200 ppm
6728821
Hydrogen Sulfide 2/b
1-60 ppm
8101961
Hydrogen Sulfide 5/b
5-600 ppm
CH29801
Hydrogen Sulfide 100/a
100-2,000 ppm
CH29101
Hydrogen Sulfide 0.2%/A
0.2-7 Vol %
CH28101
Hydrogen Sulfide 2%/a
2-40 Vol %
8101211
Hydrogen Sulfide +Sulfur Dioxide 0.2%/A
0.02-7 Vol %
CH28201

*Aerosol tubes

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: I
A Draeger short term detector tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Detector Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Iodine Iodine 0.1/a
0.1-5 ppm
8103521
Isoamyl Acetate Ethyl Acetate 200/a
200-1,000 ppm
CH20201
Isopropyl Acetate Ethyl Acetate 200/a
200-3,000 ppm
CH20201
Isopropyl Alcohol Alcohol 100/a
100-3,000 ppm
CH29701
Isopropylamine Cyclohexalamine 2/a
2-30 ppm
6728931
Isopropylbenzene (Cumene) Toluene 50/a
50-400 ppm
8101701
Isopropyl Ether Diethyl Ether 100/a
100-4,000 ppm
6730501
*Aerosol tubes Italic Font indicates SEI certification Boxes offering less than 10 tests are designated with the number of tubes in parentheses.
Draeger Short Term Detector Tubes: M

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Mercaptans Mercaptan 0.1/a
0.1-15 ppm
Mercaptan 0.5/a
0.5-5 ppm
6728981
Mercaptan 20/a
20-100 ppm
8101871
Mercury Vapor Mercury 0.1/b
0.05-2 mg/m3
CH23101
Methane Natural Gas Test (5)
Qualitative
CH20001†
Methanethiol Mercaptan 0.5/a
0.5-5 ppm
6728981
Mercaptan 20/a
20-100 ppm
8101871
Methanol Alcohol 100/a
100-3,000 ppm
CH29701
2-Methoxyethyl Acetate Ethyl Glycol Acetate 50/a
Qualitative
6726801
Methyl Acetate Ethyl Acetate 200/a
200-3,000 ppm
CH20201
Methyl Acrylate Methyl Acrylate 5/a
5-200 ppm
6728161
Methyl Alcohol Alcohol 100/a
100-3,000 ppm
CH29701
Methylamine Triethylamine 5/a
5-60 ppm
6718401
Methyl Bromide Methyl Bromide 0.2/a
0.2-8 ppm
8103391
Methyl Bromide 0.5/a
0.5-30 ppm
8101671
Methyl Bromide 5/b
5-50 ppm
CH27301
Methyl Bromide 3/a (5)
3-100 ppm
Methyl Chloroform Trichloroethane 50/d (5)
10-600 ppm
CH21101
Methyl Ethyl Ketone Acetone 100/b
100-12,000 ppm
CH22901
Methyl Isobutyl Ketone Acetone 100/b
130-15,000 ppm
CH22901
Methylisothiocyanate Methylisothiocyanate 0.1/a
0.1-6 ppm
8103485
Methyl Mercaptan Mercaptan 0.5/a
0.5-5 ppm
6728981
Mercaptan 20/a
20-100 ppm
8101871
Methyl Methacrylate Methyl Acrylate 5/a
15-700 ppm
6728161
Methyl Propyl Ketone Acetone 100/b
130-15,000 ppm
CH22901
Methylene Chloride Methylene Chloride 20/a
20-200 ppm
8103591†
Monostyrene (Styrene) Monostyrene 10/a
10-200 ppm
6723301
Monostyrene 10/b
10-250 ppm
6733141
Monostyrene 50/a
50-400 ppm
CH27601

*Aerosol tubes

†Tubes with a 6 or 12 month shelf life

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: N

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Natural Gas (Methane) Natural Gas Test (5)
Qualitative
CH20001†
Nickel Carbonyl Nickel Tetracarbonyl 0.1/a (9)
0.1-1 ppm
CH19501
Nickel Tetracarbonyl Nickel Tetracarbonyl 0.1/a (9)
0.1-1 ppm
CH19501
Nitric Acid Hydrochloric Acid/Nitric Acid 1/a
1-15 ppm HNO3
8101681
Nitric Acid 1/a
1-50 ppm
6728311
Nitric Oxide (NO) See Nitrous Fumes
Nitrogen Dioxide Nitrogen Dioxide 0.1/a
0.1–30 ppm
8103631
Nitrogen Dioxide 2/c
2-100 ppm
6719101
Nitrous Fumes (NO+NO2) Nitrous Fumes 0.5/a
0.5-10 ppm
CH29401
Nitrous Fumes 2/a
2-150 ppm
CH31001
Nitrous Fumes 20/a
20-500 ppm
6724001
Nitrous Fumes 50/a
50-2,000 ppm
8101921
Nitrous Fumes 100/c
100-5,000 ppm
CH27701

*Aerosol tubes

†Tubes with a 6 or 12 month shelf life

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: O
A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Gases & Vapors

Draeger Tubes

Measuring Range

Catalog No.

n-Octane Petroleum Hydrocarbons 10/a
10-300 ppm
8101691
Petroleum Hydrocarbons 100/a
10-2,500 ppm
6730201
Oil Mist Oil Mist 1/a
1-10 mg/m3
6733031
Oil 10/a-P
0.1 – 10 mg/m3
6728371
Olefins (Butylene, Propylene) Olefins 0.05%/a
0.06-3.2 Vol %
0.04-2.4 Vol %
CH31201
Organic Arsenic Compounds & Arsine Organic Arsenic Compounds & Arsine
3 mg org Arsenic/m3
CH26303
Organic Basic Nitrogen Compounds Organic Basic Nitrogen Compounds
1 mg/m3
CH25903
Oxirane Ethylene Oxide 1/a (5)
1-30 ppm
6728961
Ethylene Oxide 25/a
25-500 ppm
6728241
Oxygen Oxygen 5%/C
5-23 Vol %
8103261
Ozone Ozone 0.05/b
0.05-1.4 ppm
6733181
Ozone 10/a
10-300 ppm
CH21001
*Aerosol tubes Italic Font indicates SEI certification Boxes offering less than 10 tests are designated with the number of tubes in parentheses.
Draeger Short Term Detector Tubes: P

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
n-Pentane Pentane 100/a
100-1,500 ppm
6724701
Perchloroethylene Perchloroethylene 0.1/a
0.1-4 ppm
8101551
Perchloroethylene 2/a
2-300 ppm
8101501
Perchloroethylene 10/b
10-500 ppm
CH30701
Phenol Phenol 1/b
1-20 ppm
8101641
Phosgene Phosgene 0.02/a
0.02-1 ppm
8101521
Phosgene 0.25/c
0.25-25 ppm
CH28301
Phosphine Phosphine 0.01/a
0.01-1 ppm
8101611
Phosphine 0.1/a
0.1-40 ppm
CH31101
Phosphine 0.1/b in acetylene
0.1-15 ppm
8103341
Phosphine 25/A
25-10,000 ppm
8101621
Phosphine 50/a
15-3,000 ppm
CH21201
Phosphoric Acid Esters Phosphoric Acid Esters 0.05/a
0.05 ppm
6728461
Polytest Polytest
Qualitative
CH28401
Propane Hydrocarbons 0.1%/b
0.5-1.3 Vol %
CH26101
iso-Propanol Alcohol 100/a
100-3,000 ppm
CH29701
n-Propyl Acetate Ethyl Acetate 200/a
200-3,000 ppm
CH20201
Propylene Olefins 0.05%/a
0.06-3.2 Vol %
CH31201
Propylene Di-chloride Methyl Bromide 5/b
50-100 ppm
CH27301
Propylene Imine Ammonia 0.25/a
0.25-3 ppm
8101711
Pyridine Pyridine 5/A
5 ppm
6728651

*Aerosol tubes

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: S
A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Screening Tube Polytest
Qualitative
CH28401
Smoke Tube Smoke Tube
CH25301
Stoddard Solvent Petroleum Hydrocarbons 10/a
Qualitative
8101691
Styrene Monostyrene 10/a
10-200 ppm
6723301
Monostyrene 10/b
10-250 ppm
6733141
Monostyrene 50/a
50-400 ppm
CH27601
Sulfur Dioxide Sulfur Dioxide 0.1/a
0.1-3 ppm
6727101
Sulfur Dioxide 0.5/a
0.5-25 ppm
6728491
Sulfur Dioxide 1/a
1-25 ppm
CH31701
Sulfur Dioxide 20/a
20-2,000 ppm
CH24201
Sulfur Dioxide 50/b
50-8,000 ppm
8101531
Sulfuric Acid Sulfuric Acid 1/a (9)
1-5 mg/m3
6728781
Sulfuryl Fluoride Test Sulfuryl Fluoride Test (5)
1-5 ppm
8103471
Systox (Demeton) Thioether
1 mg/m3
CH25803
*Aerosol tubes Italic Font indicates SEI certification Boxes offering less than 10 tests are designated with the number of tubes in parentheses.
Draeger Short Term Detector Tubes: T

A Draeger tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Tetrachloromethane Carbon Tetrachloride 0.2/b
0.2-70 ppm
8101791
Carbon Tetrachloride 1/a (5)
1-15 ppm
8101021
Carbon Tetrachloride 5/c
5-50 ppm
CH27401
Tetrahydrofuran Alcohol 100/a
50-400 ppm
CH29701
Tetrahydrothio-phene Tetrahydrothiophene 1/b (5)
1-10 ppm
8101341
Thioether Thioether
1 mg/m3
CH25803
Toluene Toluene 5/b
5-300 ppm
8101661
Toluene 50/a
50-400 ppm
8101701
Toluene 100/a
100-1,800 ppm
8101731
Toluene Diisocyanate Toluene Diisocyanate 0.02/A (9)
0.02-0.2 ppm
6724501
Toluene-2,4-Diisocyanate (also for -2,6-) Toluene Diisocyanate 0.02/A (9)
0.02-0.2 ppm
6724501
1,1,1-Trichloroethane Trichloroethane 50/d (5)
50-600 ppm
CH21101
Trichloroethylene Trichloroethylene 2/a
2-250 ppm
6728541
Trichloroethylene 50/a
50-500 ppm
8101881
Trichlorofluoro-methane Halogenated Hydrocarbons 100/a (8)
100-1,400 ppm
8101601
Trichloromethane Chloroform 2/a (5)
2-10 ppm
6728861
Triethylamine Triethylamine 5/a
5-60 ppm
6718401
Trifluorobromo-methane Halogenated Hydrocarbons 100/a (8)
Qualitative
8101601

*Aerosol tubes

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: Vinyl Chloride

A tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Vinyl Chloride Vinyl Chloride 0.5/b
0.5-30 ppm
8101721
Vinyl Chloride 100/a
100-3,000 ppm
CH19601
Draeger Short Term Detector Tubes: Water Vapor

A tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Water Vapor Water Vapor 0.1
1-40 mg/l
CH23401
Water Vapor 0.1/a
0.05-1 mg/l
8101321
Water Vapor 1/b
1-40 mg/l
8101781
Water Vapor 3/a
3-60 lbs/mmcf
8103031

Boxes offering less thane 10 tests are designated with the number of tubes in parentheses.

Draeger Short Term Detector Tubes: Xylene
Draeger tubes for Xylene, click on the Catalog No. for further information on each tube.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Xylene (all isomers) Xylene 10/a
10-400 ppm
6733161
Draeger Short Term Detector Tubes: Zinc Chromate

A tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the table below. Select the Draeger Tube listed according to the chemical hazard to be tested and the measuring range. Order the tube by the part number that appears to the right.

Ordering Information

Click on the Catalog No. for further information on each tube. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Gases & Vapors
Draeger Tube
Measuring Range
Catalog No.
Zinc Chromate Chromic Acid 0.1/a* (9)
0.2-1 mg/m3
6728681

*Aerosol tubes

Italic Font indicates SEI certification

Boxes offering less than 10 tests are designated with the number of tubes in parentheses.

Draeger X-am 5100 Single Gas Detector for HF, HCl, H2O2 or Hydrazine
The Draeger X-am 5100 gas detector guarantees that you use the safest methods possible for handling Hydrogen Fluoride, Hydrogen Chloride, Hydrogen Peroxide or Hydrazine – thanks to proven Draeger sensor technology and a device design which is customized to reactive gases. The Draeger X-am 5100 is a small lightweight single gas monitor which is specifically designed for the requirements of personal monitoring. It ensures users a high level of comfort and convenience. The monitor can be used intuitively thanks to the practical two button control panel and straightforward menu guidance system. DragerSensors stand for innovative technology at the highest level. The Draeger XS sensors for HF/HCl, H2O2 and N2H4 are proven high performance sensors with years of successful use in the market place. The special design of the monitor with direct gas entry guarantees fast sensor response and precise measurement results and precise measurement results by preventing gas adsorption on the monitor housing. The monitor has an ingress protection rating against dust and water of IP54. The housing is resistant to impacts, vibration and electromagnetic radiation for years of reliable use. The Draeger X-am 5100 can be used with the standard NiMH rechargeable battery, optional high capacity NiMH or alkaline battery pack (2 AA batteries required). In addition, it can be recharged while still inside the instrument. Charging can take place in the workshop or in a vehicle, to suit your needs. A datalogger is standard equipment in the Draeger X-am 5100. The datalogger has a recording interval of 1 value per minute for a duration of over 1,000 hours. The data can be transmitted via infrared interface to a PC. Four alarm indicators are standard with every model of the Draeger X-am 5100. There is a loud audible horn >90dB @ 1 foot, three bright flashing, red LED’s visible from 360° and a powerful vibration alarm.

Features

  • Continuous, precise and reliable measurement
  • A special device design with direct gas entry provides fast sensor respons and precise measurement data by preventing gas adsorption on the device housing
  • Lightweight and robust
  • Slip-proof and compact design
  • Easy to use: two button operation and user friendly menus
  • Highly resistant to impacts, vibrations and electromagnetic radiation
  • Can be operated using replaceable alkaline batteries or a T4 NiMH rechargeable battery, which can be charged right in the device

Instrument Specifications

Battery Alkaline, rechargeable NiMH cells
Alarms Visual: 360° Audible: multi tone >90 dB at 1 foot Vibration
Temperature -4 to 122°F, intermittent + 130°F
Pressure 700 to 1300 hPa, 20.7 to 38.4″ Hg
Humidity 10 to 90% Rh
Datalogger Retrievable using an infrared interface > 1,000 h at a recording interval of 1 value per minute
Operating Time Alkaline battery: >150 hours NiMH rechargeable battery: >150 hours NiMH high capacity rechargeable battery: 180 hours
Charging Time <4 hours
Size 1.9″ x 5.1″ x 2.4″
Ingress Protection IP 54
Weight 8.8 ounces
Approvals ATEX: I M1 Ex ia I MA, II 1 G Ex ia IIC T4/T3 Ga IEC: Ex ia I Ma, Ex ia IIC T4/T3 Ga CSA: Class I, Div I, Groups A, B, C, D, TC T4/T3, Class I, Zone 0, A/Ex ia IIC T4/T3/Ga

Sensor Specifications

Gas
Range
Resolution
HF/HCl 0-30 ppm 0.1 ppm
H2O2 0-20 ppm 0.1 ppm
Hydrazine 0-3 ppm 0.01 ppm

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Order instrument and sensor.
Description
Catalog No.
X-am 5100 without sensors and battery 8322750
Hydrazine Sensor, 0-3.00 ppm 6809190
Hydrogen Fluoride/Hydrogen Chloride Sensor, 0-30.0 ppm 6809140
Hydrogen Peroxide Sensor, 0-20.0 ppm 6809170
Alkaline Battery Pack 8322237
NiMh Battry Pack 8318704
NiMH Battery & Charging Kit 8318785
USB-IR Communication Cable 8317409
Calibration Adapter 6806291
Deluxe Instrument Case 4543755
Power Supply for up to 5 Charge Cradles 8326994
Power Supply, Vehicle Adapter, 12 VDC 4530057
Battery Charging Set includes charge cradle & single power supply 8320333
Battery Charge Cradle 8318639

Downloads

X-am 5100 gas detector literature
Draeger X-am 5600 6 Gas Detector with Infrared
Featuring an ergonomic design and innovative infrared sensor technology, the Draeger X-am 5600 is the smallest gas detection instrument for the measurement of up to 6 gases. Ideal for personal monitoring applications, this robust and water-tight detector provides accurate, reliable measurements of explosive, combustible and toxic gases and vapors as well as oxygen. Small, light and easy to use – the robust and water tight X-am 5600 gas detector is designed for single handed operation in tough industrial environments. Water and dust-proof according to IP67 and with an integrated rubber boot, the device provides optimal functionality even under harsh conditions. Thanks to the high stability and a resistance to contamination, Draeger infrared sensors can generally be used for up to 8 years. This advanced technology reduces the cost of ownership considerably because less replacement sensors are needed. In addition, a sensor calibration is only necessary every 12 months which reduces maintenance costs. The infrared sensor IR Ex allows the measurement of explosive, combustible hydrocarbons in the range of the lower explosive limit. The infrared sensor IR CO2, with a measurement resolution of 0.01Vol%, provides safe and exact measurements as well as a warning against toxic concentrations of carbon dioxide in ambient air. For those applications where the reliable measurement of explosive substances and CO2 is specifically needed, the advantages of both can be achieved by a dual sensor (Dual IR CO2/Ex) Besides hydrocarbons, hydrogen can also be an explosive gas. Because sensors based on infrared technology do not warn hydrogen explosion dangers, the gas detector X-am 5600 combines two sensor signals (infrared Ex and electrochemical H2) or reliable hydrogen detection. The X-am 5600 provides the advantages of poison free technology to be used in areas where, until now, only catalytic Ex sensors have been used. Thanks to the combination of innovative infrared technology and the latest electrochemical Draeger XXS miniature sensors, this 1 to 6 gas detector reliably detects explosive, combustible, and harmful concentrations of O2, Cl2, CO, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2, O3, Amine, odorant, COCl2 and organic vapors. With the PC software Draeger CC-Vision, the sensors can easily be exchanged, calibrated or converted to meet the needs of different applications. An optional external pump which can be operated with hoses up to 45M in length is the perfect solution for pre-entry measurements in tanks or pipelines. This small and reliable gas detector is suitable for use in areas classified as zone O, which are areas where explosive atmospheres are always to be expected.

Features

  • Gas entry from two sides
  • 360° visual alarm
  • Retro reflectors make to unit easy to find in the dark
  • Fast and accurate Draeger Sensors
  • A visual life signal indicates the continuous operation of the infrared sensor
  • Large display
  • Easy two button operation

Instrument Specifications

Battery Alkaline, rechargeable NiMH cells for alkaline pack, T4 battery pack
Alarms Visual: 360° Audible: multi tone >90 dB at 1 foot Vibration
Temperature -4 to 122°F, intermittent + 130°F
Pressure 700 to 1300 hPa, 20.7 to 38.4″ Hg
Humidity 10 to 95% Rh
Datalogger Can be read via infrared about 1000 hours with 6 gases and a recording interval of 1 reading per minute
Operating Time >10 hours
Charging Time <4 hours
Size 1.85″ x 5.12″ x 1.73″
Pump Operation Maximum hose length 45 M
Weight 8.8 ounces
Approvals ATEX: I M1 Ex ia I MA, II 1 G Ex ia IIC T4/T3 Ga IEC: Ex ia I Ma, Ex ia IIC T4/T3 Ga for MOG 01 ATEX: I M1 Ex ia I, II 1G Ex ia IIC T3 CSA: Class I, Div I, Groups A, B, C, D, TC T4/T3, Class I, Zone 0, A/Ex ia IIC T4/T3/Ga

Sensor Specifications

Gas
Range
Resolution
Dual IR Ex/CO2
0-100% LEL, 0-100% Vol % Methane, Propane, Ethylene 0-5 Vol % CO2
1% LEL, 0.1 Vol % CH4 0.01 Vol% CO2
IR Ex
0-100% LEL 0-100 Vol % Methane, Propane, Ethylene
1% LEL 0.1 Vol % CH4
IR CO2
0-5 Vol%
0.01 Vol%
CO/H2S
0-2,000 ppm CO 0-100 ppm H2S
1 ppm CO 0.1 ppm H2S
Carbon Monoxide (CO)
0-2,000ppm
2 ppm
Carbon Monoxide High Range
0-10,000ppm
5 ppm
Carbon Monoxide H2 Compensated
0-2,000ppm
2 ppm
Hydrogen Sulfide (H2S)
0-200 ppm
1 ppm
Hydrogen Sulfide, Low Range
0-100 ppm
0.1 ppm
Hydrogen Sulfide, High Range
0-21,000 ppm
2 ppm
Oxygen (O2)
0-25 Vol %
0.1 % Vol
Nitric Oxide (NO) 0-200 ppm 0.1 ppm
Nitrogen Dioxide (NO2) 0-50 ppm 0.1 ppm
Sulfur Dioxide (SO2) 0-100 ppm 0.1 ppm
Phosphine (PH3) 0-20 ppm 0.01 ppm
Phosphine High Range 0-2,000 ppm 1 ppm
Hydrogen Cyanide (HCN) 0-50 ppm 0.1 ppm
Ammonia (NH3) 0-300 ppm 1 ppm
Carbon Dioxide (CO2) 0-5 Vol % 0.1 Vol %
Chlorine (Cl2) 0-20 ppm 0.05 ppm
Hydrogen (H2) 0-2,000 ppm 5 ppm
Hydrogen High Range (H2) 0-4 Vol % 0.01 Vol %
Organic Vapor 0-200 ppm 0.5 ppm
Organic Vapor-A 0-200 ppm 1 ppm
Amines 0-100 ppm 1 ppm
Odorant 0-40 ppm 0.5 ppm
Phosgene 0-10 ppm 0.01 ppm
Dual O2/CO O2: 0-25% Vol CO: 0-2000 ppm O2: 0.1% CO: 1ppm

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
X-am 5600, order sensors below
8321050
NiMH Rechargeable Battery
8318704
High Capacity NiMH Rechargeable Battery
8322244
NiMH Rechargeable Battery and Charger
8318785
Alkaline Battery Pack without batteries
8322237
X-am External Pump
8327115
Confined Space Kit includes pump with USB cable & charger, case, X-am charger & wall plug, alkaline battery adapter, DIRA Dongle & cradle, probe with hose, float probe, cal gas and regulator
8327106
Bump Test Station
8319131
GasVision Software
8314034
Deluxe Instrument Case 4543755
USB-IR Cable
8317409

Sensor Ordering Information

Description
Catalog No.
Dual IR Ex/CO2 Sensor
6811960
IR Ex Sensor
6812180
IR CO2 Sensor
6812190
Oxygen Sensor
6810881
Carbon Monoxide Sensor
6810882
Carbon Monoxide Sensor, high range
6812010
Hydrogen Sulfide Sensor
6810883
Hydrogen Sulfide Sensor, high range
6812015
Nitrogen Dioxide Sensor
6810884
Sulfur Dioxide Sensor
6810885
Phosphine Sensor
6810886
Phosphine Sensor, high range
6812020
Hydrogen Cyanide Sensor
6810887
Ammonia Sensor
6810888
Carbon Dioxide Sensor
6810889
Chlorine Sensor
6810890
Organic Vapor Sensor
6811530
Organic Vapor-A Sensor
6811535
Hydrogen Sulfide Sensor LC, Low Concentration
6811525
Carbon Monoxide/Hydrogen Sulfide Sensor
6813280
Carbon Monoxide H2 Compensate Sensor
6811950
Hydrogen Sulfide Low Concentration Sensor
6811525
Hydrogen High Concentration Sensor
6812025
Nitric Oxide Sensor
6811545
Amines Sensor
6812545
Mercaptan Sensor
6812535
Phosgene Sensor
6812005
Oxygen Sensor Sensor, 5 year Warranty
6812211
Carbon Monoxide Sensor, 5 year Warranty 6812212
Hydrogen Sulfide Sensor, 5 year Warranty 6812213
Dual O2/CO Sensor 6813275

Downloads

X-am 5600 literature
Draeger X-am 8000 Gas Detector With PID

Clearance measurement was never this easy and convenient: The Draeger X-am 8000 measures up to 7 toxic as well as flammable gases, vapors and oxygen all at once – either in pump or diffusion mode. Innovative signaling design and handy assistant functions ensure complete safety throughout the process.  The Draeger X-am 8000 is equipped with a very powerful internal pump. It can be connected with hoses up to 45 meters in length. A pump adapter makes it easy to switch between diffusion and pump mode at any time. This means the pump is only operated when you actually need it. That saves energy, reduces wear and tear and thereby extends the lifespan of the pump.

Handy and durable, the Draeger X-am 8000 is intuitive to operate single handedly using three function keys. The easy to read color display clearly lays out all the information for you. Standard accessories include a sturdy shoulder strap, so you can comfortably carry the X-am 8000. thanks to its compact and robust construction, the device can withstand even the harshest conditions.

The X-am 8000 effectively supports various applications with specially developed assistant functions that guide you through each process step by step. During clearance measurement, for example, the smart assistant calculates gases, temperature limits and the indicated hose length. When monitoring for high methane concentrations, a configurable automatic measurement range switch makes it easier to take a reading: if the Cat-Ex sensor measures values above 100% LEL, the display switches to the range of 0 to 100% Vol.

The signal system of the X-am 8000 is based on a clear color code:

  • Red light = gas alarm
  • Yellow light = device related alarm, e.g. low battery
  • Green light = device is ready for use

The green glow of the D-light allows you to see from a distance whether the device has been properly tested and is ready for use. In case of an alarm, the X-am 8000 alerts you with colorful alarms LEDs, a loud horn (100 dB(A) at a distance of 30 cm) and clearly palpable vibration. Optionally, four preset hazards symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards. This allows the user to easily recognize the type of hazard based purely on the symbol displayed.

The X-am 8000 is equipped with a shock detection system. The event report indicates whenever severe mechanical impacts have occurred that might result in functional impairments of the device or the sensors. There are also documented in the data logger.

Bump Test and calibration are carried out simply and quickly using the Draeger X-Dock calibrating station. Its low test gas consumption keeps operating costs to a minimum. Its reporting function and numerous other useful features make the X-dock Manager PC software a smart addition to any fleet management operation. To identify the devices in the fleet, you can either use tried and tested barcodes or an integrated RFID transponder

To measure had to detect hydrocarbons, you can fit the Draeger X-am 8000 with one of two high performance PID sensors. The PID HC covers a measurement range of 0-2,000 ppm. The PID LC ppb is particularly suited for a measurement range of 0-10 ppm with a resolution range below 1 ppm. For benzene specific measurements, the X-am 8000 can be used with a pre-tube. The advantage: you only need one measuring device for this application, which significantly reduces the costs of purchasing and maintaining and transporting devices in use. The use of the pre-tubes is supported by a built in assistant.

The X-am 8000 features inductive charging. This makes it easier to operate and increases the lifespan of the device. Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) an measure at the same time, e.g. when in use inside vehicles or machinery. The charging cradles can connect with one another, taking up minimal space and are compatible with existing X-am series cradles.

Instrument Specifications

Display High contrast color display
Housing Durable two component housing
Alarms Visual: 3 LED red, 3 LED yellow
Acoustic: Multi-tone 100 dBA at 30cm
Vibration
IP IP 67
Battery Li-Ion battery, rechargeable, inductive charging
Operating Times CatEx & 3 toxic sensors: 24 hours
IR & 3 toxic sensors: 22 hours
3 toxic sensors: 120 hours
CatEx, PID & 3 toxic sensors: 17 hours
IR, PID & 3 toxic sensors: 16 hours
PID: 42 hours
Charging Time Typically 4 hours
Start Up Times <60 seconds
Data Storage 210 hours
Pump Operation 147.6 feet
Temperature -4 to 122°F
Humdity 10 – 90% rH
Weight 17.5 ounces
Dimensions 7″ x 3″ x 1.7″
Approvals ATEX: I M1, II 1G, ex da ia I Ma, Ex da ia IIC t4 Ga
CSA: Class I, Zone 0, AEx di ia IIC T4 Ga, Class II, Div 1, Ge E F G T4
CE
Warranty 3 years for instrument
1 year for power supply

Sensor Specifications

Gas
Range
Catalog No.
CO LC XXS
0-2,000 ppm
6813210
H2S LC XXS 0-100 ppm 6811525
Oxygen XXS 0-25% Vol 6810881
NO2 XXS 0-50 ppm 6810884
SO2 XXS 0-100 ppm 6810885
Dual CO & H2S LC XXS CO: 0-2000 ppm
H2S: 0-100 ppm
6813280
Dual CO & O2 XXS CO: 0-2000 ppm
O2: 0-25% Vol
6813275
Dual H2S & O2 XXS H2S: 0-100 ppm
O2 0-25% Vol
6814137
Amines XXS 0-100 ppm 6812545
Ammonia XXS 0-300 ppm 6810888
Carbon Dioxide XXS 0-5% Vol 6810889
CO HC XXS 0-10,000 ppm 6812010
CO H2 Compensated XXS 0-2000 ppm 6811950
Chlorine XXS 0-20 ppm 6810890
Hydrogen HC XXS 0-4% Vol 6812025
Hydrogen LC XXS 0-2,000 ppm 6812370
Hydrogen Cyanide XXS 0-50 ppm 6813165
Hydrogen Cyanide XXS 0-50 ppm 6810887
H2S HC XXS 0-1,000 ppm 6812015
Mercaptan XXS 0-40 ppm 6812535
Nitric Oxide XXS 0-200 ppm 6811545
NO2 XXS 0-50 ppm 6812600
Organic Vapor XXS 0-200 ppm 6811530
Organic Vapor A XXS 0-200 ppm 6811535
Oxygen XXS 0-100% Vol 6812385
Ozone XXS 0-10 ppm 6811540
Phosgene XXS 0-10 ppm 6812005
Phosphine HC XXS 0-2000 ppm 6812020
Phosphine XXS 0-20 ppm 6810886
PID HC 0-2000 ppm 6813475
PID LC (ppb) 0-10 ppm 6813500
Cat Ex 125 0-100% LEL 6812950
Dual IR EX/CO2 LEL: 0-100%
CH4: 0-100 Vol%
CO2: 0-5 Vol%
6811960
IR EX LEL: 0-100 %
CH4: 0-100 Vol%
6812180
IR CO2 0-5 Vol% 6812190

Ordering Information

Many X-am 8000 versions are available including an infrared hydrocarbon sensor and infrared carbon dioxide sensor. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Downloads

X-am 8000 literature

Tags: Ammonia gas detector, Carbon Monoxide gas detector, Combustible gas detector, Hydrogen Sulfide gas detector, Oxygen gas detector, Amine gas detector, Chlorine  gas detector, Chlorine Dioxide gas detector, Carbon Dioxide  gas detector, Phosgene  gas detector, Hydrogen  gas detector, Hydrogen Cyanide gas detector, Nitric Oxide gas detector, Nitrogen Dioxide gas detector, Sulfur Dioxide gas detector

Flow Check Air Flow Indicator from Draeger Safety

The Flow Check Air Flow Indicator can detect the slightest air movements. It produces a harmless cloud of smoke that floats freely and easily. With the Flow Check Air Flow Indicator, the slightest air movements become visible. The Flow Check is ideal for checking ventilation or air conditioning systems, chimneys or to detect leaks in industrial equipment. Also, when it comes to the detection of contaminants in work areas, knowledge about air movements is quite useful in order to find out the best locations for measurement of contaminant concentrations.

The Flow Check consists of an instrument for the production of the clouds and an ampule containing smoke generating fluid. The ampule contains a fluid that is a special mixture of alcohols developed at Draeger. A small heating element in the head of the instrument heats the fluid which condenses on contact with the ambient air. The temperature of the heating element and the quantity of the fluid is electrically balanced.

Small, single clouds can be generated with a short press of a button. If a continuous production of clouds is desired, the button can be held or locked in the “on” position. The fluid is located in a compartment in the handle of the instrument and can be inserted effortlessly into position. The amount of fluid contained in the ampule is enough to generate approximately three minutes. Power is supplied by a battery located in the handle of the instrument.

Specifications

Smoke Time per Ampule about 3 minutes
Operating Time per Battery Charge about 20 minutes
Temperature 5 to 40ºC
Dimensions 300mm x 200 mm x 70 mm
Weight 500 g

Ordering Information

Each unit includes 3 smoke ampules, battery pack, hose inlets and a carrying case. A battery charger is required. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
Flow Check Air Flow Indicator
6400761
Charger, 100 VAC, required
8316993
Smoke Ampules, pk/3
6400812
Battery Pack 6400817
Hose Inlet 6400818

Downloads

Flow Check Air Flow Indicator Datasheet

HazMat Simultest Tube Kit from Draeger Safety

The Draeger HazMat Simultest Kit is based on the Simultaneous Tube Sets I, II & III. These sets are designed to detect gases evolved as the result of a structural fire and to determine organic chemical families. The HazMat Simultest does not require a complex, confusing matrix card used to determine what gases and vapors are present. Each test takes a total of one minute or less to conclude, therefore, the complete testing time for ten gases and five organic chemical families is less than five minutes.

The HazMat Simultest Kit includes the Accuro bellows pump, air current kit, 1 meter extension hose with adapter, 3 each of Simultaneous Test Sets I, 3 each of Simultaneous Test Set II & 4 each of Simultaneous Test Set III, Accuro spare parts kit, simultaneous test set opener and laminated instruction cards that have full color graphics making interpretation of the tubes quick and easy. A rugged Pelican carrying case protect the kit contents.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
HazMat Simultest Kit
4056098
HazMat Simultest Kit without Accuro Pump
4056447
Simultest Extension Hose, includes 1M hose, adapter & opener
6400561
Simultest Set Opener
6400095
Laminated Instruction Card for Set I & II
4056092
Laminated Instruction Card for Set III
4056091
Tube Warmer
8316130
Hazmat Simultest Training CD
4056561

Spare Tube Ordering Information

Description
Catalog No.
Simultaneous Test Set I, Inorganic fumes includes Acid Gases, e.g. Hydrochloric Acid, Basic Gases, e.g. Ammonia, Carbon Monoxide, Hydrocyanic Acid and Nitrous Gases, e.g. Nitrogen Dioxide
8101735
Simultaneous Test Set II, Inorganic fumes includes Phosphine, Chlorine, Hydrogen Sulfide, Phosgene and Sulfur Dioxide
8101736
Simultaneous Test Set III, Organic Vapors includes Alcohols, e.g. Methanol, Aliphatic Hydrocarbons, e.g. n-Hexane, Aromatics, e.g. Toluene, Chlorinated Hydrocarbons, e.g. Perchloroethylene and Ketones, e.g. Acetone
8101770

Downloads

Hazmat Simultest Kit Literature

HazMat Tube Kit from Draeger Safety

The HazMat Kit is designed to aid in the initial assessment of potentially hazardous situations. The detector tubes included in the kit have been selected to utilize a systematic sampling matrix. Using the Polytest Tube as a starting point, the sampling matrix provides a systematic test sequence to obtain information about the chemical group to which an unknown substance may belong. The HazMat Kit can also be used for providing quantitative measurement of specific gases and vapors.

Evaluation of test results can be performed on-site, without delay.

Housed in a durable, lightweight case, the HazMat Kit includes the Draeger Accuro Pump with an integrated stroke counter and end of stroke indicator, 3 meter extension hose for testing inaccessible areas and an Air Current Kit for determining wind direction and velocity. Other contents include spare parts for pump maintenance and 17 types of detector tubes. The components fit