Chip Measurement System


Chip Measurement System

The CMS combines substance specific measuring Chips with an electronic based Analyzer for an easy to use spot-measurement system.

4
Yes
None
1
60
Search...
/gas-detection-instruments/detector-tubes/chip-measurement-system/
Thumbnail
Sort By:

Categories:

Tags:

Manufacturer:

Model:

Short Description:

' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series D12 gas transmitter product line has been expanded. Now available in this versatile package is an LEL transmitter utilizing an Infrared sensor that resists the poisoning problems inherent in catalytic bead sensors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ATI's Series PQ45 is the answer to the need for a rugged field deployed package capable of measuring and recording water quality data in a variety of operating environments.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Allegro's Air Filtration Panels convert shop air used for pneumatic tools and equipment to clean breathable air.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Area monitoring reinvented. That's what Draeger's X-zone 5500 brings to a worksite: a safer, more effective way to monitor for hazardous gases. In combination with the Draeger X-am 5000, 5100 or 5600 gas detection instruments, the X-zone 5500 can be used for the measurement of up to six gases and extends the range of your portable gas detection technology.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Breathe cool, stay safe: Draeger X-plore 1750 and 1760 is Draeger's new generation particle filtering face piece respirators, coming with distinct improvements in comfort and protection.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Combining versatility, ease of use and the latest breathing apparatus design, Draeger's PAS Micro is among the most technologically advanced, short duration emergency escape units available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Draeger's PAS Colt combines versatility, ease of use and the latest in breathing apparatus design. It is among the most technologically advanced, short duration emergency escape unit available.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

ER2000 Escape Respirator is a hood style full face respirator that provides respiratory protection from Nuclear, Biological and Chemical (NBC) warfare agents as well as Toxic Industrial Materials (TIM's).

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

FMC 2000 is a multi-channel controller with built in modem designed for integration with Rae Systems' wireless mesh network products. It is simple to install and operate, versatile, and dependable.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

For qualitative fit testing of air purifying respirators this Smoke Test Kit offers everything needed for meeting OSHA's protocol for fit testing with smoke.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Perfect for storing APR's cartridges and other respirator accessories such as fit testing kits, storage bags and cleaning supplies.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' Hand pump if for use with Rae's line of gas detection tubes.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' MultiRae Lite is a perfect wireless monitoring solution for personal protection. It can monitor up to six gases and thrives in confined space entry situations. This tool comes in either with an internal pump or diffusion monitor and is compatible with more than 30 sensor options allowing it to fully meet the monitoring requirements of any application.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' large selection of colorimetric gas detection tubes offer quick, on the spot measurements of a wide range of toxic and combustible gases and vapors.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

Rae Systems' ppbRae 3000 is a state of the art VOC gas detector for monitoring at the parts per billion (ppb) level. This device uses a new generation of photo ionization detector (PID) and features both temperature and humidity compensation for improved accuracy. It includes built in correction factors for over 200 compounds and is suitable for use in any hazardous environment.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Casella dBadge2 Noise Dosimeter keeps all the great attributes of the original dBadge but adds incredible features you won't want to do without!

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Draeger single cartridge system keeps cartridges and filters out of the wearer's line of vision without sacrificing service life or breathing comfort. the threaded adapter on the cartridges makes change out simple, quick and sure.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The GfG G460 combustible gas detector is the world's most advanced multi-sensor atmospheric monitor. The durable G460 continuously measures and displays readings for up to six gases at the same time.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae 2000 is no longer available. The MiniRae 3000+ has replaced the MiniRae 2000. The MiniRae 3000+ is Rae Systems most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector's (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The MiniRae Lite from Rae Systems is the most reliable handheld portable volatile organic compound (VOC) monitor on the market. Its photo ionization detector's (PID) range of 0 to 5,000 ppm makes it an ideal instrument for application ranging from environmental to construction.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Rae Systems MultiRae Pro is the industry's first wireless multi threat detection tool that combines continuous monitoring capabilities for gamma radiation, volatile organic compounds (VOCs), toxic, combustible gases and oxygen with Man Down Alarm functionality in one highly portable instrument.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The ToxiRae Pro is the world's first wireless personal monitor for toxic gases and oxygen. The Rae Systems ToxiRae Pro takes worker protection to the next level by providing safety professionals wireless access to real time instrument readings and alarm status (including man down alarm) from any location for better visibility and faster response.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The use of ozone gas is increasing rapidly in a wide variety of applications, such as water treatment, odor control and food processing. ATI's Model A23-14 is a portable generator designed to produce an ozone gas concentration below 1 ppm.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This Point of Attachment (POA) Air Control System connects to any breathing air source. It's housed in a Pelican carry case that can be wall mounted and includes an adjustable pressure regulator, pressure gauge and a pressure relief valve.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This heat stress meter features bright multi-color LCD backlights corresponding to OSHA's heat stress alert levels.

' class='jquery-prod-cf-value' />
' onclick='UPCP_DisplayPage("1"); UPCPHighlight(this, "Grey");' id='cf-4-

This unique sound meter enables remote sound level readings using a detachable probe. It features an RS232 computer interface, AC output and a coiled probe that extends to 9'.

' class='jquery-prod-cf-value' />
Chip Measurement System (CMS) from Draeger

The Draeger CMS is ready for use after only a brief instruction. It makes no difference which gas or vapor you wish to measure – the instrument is used in the same way every time. The operation is guided by a menu on the display and a single button/switch. The display can be backlit. After an automatic system self-test, the analyzer is powered up and the measurement system is immediately ready for operation. Simply insert the chip, perform the measurement and read the measurement result displayed as a concentration on the screen. At the end of the measurement, the chip is automatically ejected from the instrument, and the analyzer shuts down. An audible signal sounds after each operating step. Power is supplied by 4 standard and easily replaceable batteries which are especially suited to the analyzer’s requirement. The battery capacity allows for more then 7 hours of measurement and is display on the screen.

The principle of mass current measurement ensures that the instrument remains unaffected by fluctuations in air pressure. Because the chips are calibrated before leaving the factory, there is no need for the user to calibrate the CMS. Any possible temperature and humidity effects are checked during factory calibration. The analyzer is explosion protected and certified in accordance with UL, UL/CAS and Cenelec. In addition, the system is protected against dust and splash water in accordance with IP54 and is resistant to electromagnetic waves.

To allow measurement at places which are difficult to access, a remote system is available. This comprises of an additional pump and extension hose is is connected to the back of the analyzer. Because the remote system is activated by its own switch, the system can remain attached to the analyzer. A telescopic probe can also be attached to the remote system.

A kit for emergency response is now available. It includes an analyzer, remote system, telescopic probe, 10 chips, flashlight/lantern, notepad and a chip case. Note: Chips marked with a (*) are included with this kit.

Specifications

Measurement & Resolution Depends on chip type used
Typical Measurement Time 30 seconds to 5 minutes in range of the limit values, depends on chip type and concentration of hazardous substance
Temperature, Operation 32-104°F
Humidity 0-95%
System Diagnosis Automatic with micro controller for all system components
Display LCD, alphanumeric with backlighting
Operating Time About 45 minutes
Power Supply 4 x 1.5V alkaline batteries
Protection Class IP54
Weight 26 ounces
Dimensions 8.5″ x 4″ x 2.5″
Approvals  UL: Class 1 Div 1, Groups A, B, C, D, Temp Code T4, 2P91

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
CMS Analyzer Set, includes analyzer, allen wrench and batteries
6405300
CMS Analyzer Set with Remote System includes pump, 3M extension hose with adapter, float probe, screwdriver, allen wrench & batteries
8317700
Remote System for measurement of inaccessible place, includes 3M of hose with adapter, screwdriver & float probe
6405060
CMS Emergency Response Kit includes analyzer, remote system, telescopic probe, 10 chips (*) and carrying case
4055711
CMS Emergency Response Kit without Chips, includes analyzer, remote systems, telescopic probe and carrying case
4055976
CMS Indoor Air Quality Kit, includes analyzer, batteries, nylon transport case and 1 each of Carbon Dioxide, Carbon Monoxide, Formaldehyde and Ozone Chips
4056455
Telescopic Probe with FKM Sampling Hose, remote system required
8316530
CMS Sampling Hose with Adapter and Float Probe, remote system required, 3M
8317614
CMS Sampling Hose with Adapter and Float Probe, remote systems required, 10M 8317613
CMS Extension Hose Adapter
8319269
Training Chip
6406290
Soft Side Case for analyzer and chips
4594631
Molded Plastic Transport Case
4056442
CMS Emergency Response Case with foam inserts, holds 14-16 chips
4055979
CMS Handbook
9092086
CMS Training CD
4056637

Ordering Information – Chips

Chip
Measuring Range
Catalog No.
Acetic Acid
2.0-50.0 ppm
6406330
Acetone
40.0-600 ppm
6406470
Ammonia
0.20-5.0 ppm
6406550
Ammonia
2.0-50.0 ppm
6406130
Ammonia*
10.0-150 ppm
6406020
Ammonia
100-2,000 ppm
Benzene
50 – 2,500 ppb
6406600†
Benzene(**)*
0.20-10.0 ppm
6406030†
Benzene(**)
0.50-10.0 ppm
6406160†
Benzene
10.0-250 ppm
6406280
Butadiene
1.0-25.0 ppm
6406460
Carbon Dioxide
200-3,000 ppm
6406190
Carbon Dioxide*
1,000-25,000 ppm
6406070
Carbon Dioxide
1.0-20% vol
6406210
Carbon Monoxide*
5.0-150 ppm
6406080
Chlorine*
0.20-10.0 ppm
6406010
Ethanol
100-2,500 ppm
6406370
Ethylene Oxide
0.40-5.0 ppm
6406580
Formaldehyde
0.20-5.0 ppm
6406540
Hydrochloric Acid*
1.0-25.0 ppm
6406090
Hydrochloric Acid
20.0-500 ppm
6406140
Hydrogen Cyanide††
2.0-50.0 ppm
6406100
Hydrogen Peroxide††
0.20-2.0 ppm
6406440
Hydrogen Sulfide
0.20-5.0 ppm
6406520
Hydrogen Sulfide*
2.0-50.0 ppm
6406050
Hydrogen Sulfide
20.0-500 ppm
6406150
Hydrogen Sulfide
100-2,500 ppm
6406220
Iso-Propanol
40.0-1,000 ppm
6406390
Mercaptan
0.25-6.0 ppm
6406360
Methanol
20.0-500 ppm
6406380
MTBE
10.0-200 ppm
6406530
Methylene Chloride††
20.0-400 ppm
6406510
Nitrogen Dioxide*
0.50-25.0 ppm
6406120
Nitrous Fumes*
0.50-15.0 ppm
6406060
Nitrous Fumes
10.0-200 ppm
6406240
Oxygen
1.0-30.0% Vol
6406490
Ozone††
25.0-1,000 ppb
6406430
Perchloroethylene*††
5.0-500 ppm
6406040
Petroleum Hydrocarbons
20.0-500 ppm
6406200
Petroleum Hydrocarbons
100-3,000 ppm
6406270
Phosgene
0.05-2.0 ppm
6406340
Phosphine
0.10-2.5 ppm
6406400
Phosphine
1.0-25.0 ppm
6406410
Phosphine
20.0-500 ppm
6406420
Phosphine
200-5,000 ppm
6406500
Propane
100-2,000 ppm
6406310
Styrene
2.0-40.0 ppm
6406560
Sulfur Dioxide
0.40-10.0 ppm
6406110
Sulfur Dioxide
5.0-150 ppm
6406180
Toluene
10.0-300 ppm
6406250†
Training Chip
6406290
Trichloroethylene††
5.0-100 ppm
6406320
Vinyl Chloride
0.30-10.0 ppm
6406170
Vinyl Chloride
10.0-250 ppm
6406230
Water Vapor
0.40-10.0 mg/L
6406450
Xylene
10.0-300 ppm
6406260†

†Chips with cold storage requirement; to be stored at or below 50°F, do not freeze.

††Chips with a 6-12 month shelf life.

(**)Please Note: The two Benzene chips in the CMS program have nearly the same measurement range. The primary difference is the humidity limits. The Benzene 0.5-10 ppm chip is designed for high humidity environments. Please refer to the following table.

Maximum Humidity,
Benzene 0.2-10 ppm
Temperature °F
Maximum Humidity, Benzene 0.5-10 ppm
100%
32
100%
100%
50
100%
100%
68
100%
99%
86
100%
76%
95
100%
60%
104
80%

Performance Data

Measuring Range & Resolution Depends on the chip type
Typical Measuring Time 1-2 minutes in the range of the limit values, dependent on the chip type and the concentration of the hazardous substance
Contamination Effects Not possible
Calibration Not necessary
Operational Temperature 34 to 104°F (0 to 40°C)
Storage Temperature; Analyzer -4 to 140°F (-20 to 60°C)
Storage Temperature; Chips <77°F (<25°C)
Atmospheric Pressure 700 to 1,100 HpA (or Mbar)
Humidity 0 to 95% relative, not condensed
Determination of the Measurement Value Optics & light transfer system reflective measurement
System Diagnostics Self-performing, microprocessor controlled for all components of the system
Display LCD, 2 x 16 alphanumeric digits with backlight
Menu Languages English, German, French, Spanish
Operational Capacity Approximately 450 minutes on one set of batteries
Power Source 4 x 1.5V (AA) alkaline batteries
Weight 1.6 pounds (730g)
Dimensions 8″ x 3.6″ x 1.7″
Approvals UL Class 1, Div. 1, Groups A, B, C, D, Temp Code T4
Protection Class Dust & water spray protection according to IP54
Chip Measurement System (CMS) from Draeger
The Draeger CMS is ready for use after only a brief instruction. It makes no difference which gas or vapor you wish to measure – the instrument is used in the same way every time. The operation is guided by a menu on the display and a single button/switch. The display can be backlit. After an automatic system self-test, the analyzer is powered up and the measurement system is immediately ready for operation. Simply insert the chip, perform the measurement and read the measurement result displayed as a concentration on the screen. At the end of the measurement, the chip is automatically ejected from the instrument, and the analyzer shuts down. An audible signal sounds after each operating step. Power is supplied by 4 standard and easily replaceable batteries which are especially suited to the analyzer’s requirement. The battery capacity allows for more then 7 hours of measurement and is display on the screen. The principle of mass current measurement ensures that the instrument remains unaffected by fluctuations in air pressure. Because the chips are calibrated before leaving the factory, there is no need for the user to calibrate the CMS. Any possible temperature and humidity effects are checked during factory calibration. The analyzer is explosion protected and certified in accordance with UL, UL/CAS and Cenelec. In addition, the system is protected against dust and splash water in accordance with IP54 and is resistant to electromagnetic waves. To allow measurement at places which are difficult to access, a remote system is available. This comprises of an additional pump and extension hose is is connected to the back of the analyzer. Because the remote system is activated by its own switch, the system can remain attached to the analyzer. A telescopic probe can also be attached to the remote system. A kit for emergency response is now available. It includes an analyzer, remote system, telescopic probe, 10 chips, flashlight/lantern, notepad and a chip case. Note: Chips marked with a (*) are included with this kit. Specifications Measurement & Resolution Depends on chip type used Typical Measurement Time 30 seconds to 5 minutes in range of the limit values, depends on chip type and concentration of hazardous substance Temperature, Operation 32-104°F Humidity 0-95% System Diagnosis Automatic with micro controller for all system components Display LCD, alphanumeric with backlighting Operating Time About 45 minutes Power Supply 4 x 1.5V alkaline batteries Protection Class IP54 Weight 26 ounces Dimensions 8.5″ x 4″ x 2.5″ Approvals  UL: Class 1 Div 1, Groups A, B, C, D, Temp Code T4, 2P91 Ordering Information For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com. Description Catalog No. CMS Analyzer Set, includes analyzer, allen wrench and batteries 6405300 CMS Analyzer Set with Remote System includes pump, 3M extension hose with adapter, float probe, screwdriver, allen wrench & batteries 8317700 Remote System for measurement of inaccessible place, includes 3M of hose with adapter, screwdriver & float probe 6405060 CMS Emergency Response Kit includes analyzer, remote system, telescopic probe, 10 chips (*) and carrying case 4055711 CMS Emergency Response Kit without Chips, includes analyzer, remote systems, telescopic probe and carrying case 4055976 CMS Indoor Air Quality Kit, includes analyzer, batteries, nylon transport case and 1 each of Carbon Dioxide, Carbon Monoxide, Formaldehyde and Ozone Chips 4056455 Telescopic Probe with FKM Sampling Hose, remote system required 8316530 CMS Sampling Hose with Adapter and Float Probe, remote system required, 3M 8317614 CMS Sampling Hose with Adapter and Float Probe, remote systems required, 10M 8317613 CMS Extension Hose Adapter 8319269 Training Chip 6406290 Soft Side Case for analyzer and chips 4594631 Molded Plastic Transport Case 4056442 CMS Emergency Response Case with foam inserts, holds 14-16 chips 4055979 CMS Handbook 9092086 CMS Training CD 4056637 Ordering Information – Chips Chip Measuring Range Catalog No. Acetic Acid 2.0-50.0 ppm 6406330 Acetone 40.0-600 ppm 6406470 Ammonia 0.20-5.0 ppm 6406550 Ammonia 2.0-50.0 ppm 6406130 Ammonia* 10.0-150 ppm 6406020 Ammonia 100-2,000 ppm 6406570 Benzene 50 – 2,500 ppb 6406600† Benzene(**)* 0.20-10.0 ppm 6406030† Benzene(**) 0.50-10.0 ppm 6406160† Benzene 10.0-250 ppm 6406280 Butadiene 1.0-25.0 ppm 6406460 Carbon Dioxide 200-3,000 ppm 6406190 Carbon Dioxide* 1,000-25,000 ppm 6406070 Carbon Dioxide 1.0-20% vol 6406210 Carbon Monoxide* 5.0-150 ppm 6406080 Chlorine* 0.20-10.0 ppm 6406010 Ethanol 100-2,500 ppm 6406370 Ethylene Oxide 0.40-5.0 ppm 6406580 Formaldehyde 0.20-5.0 ppm 6406540 Hydrochloric Acid* 1.0-25.0 ppm 6406090 Hydrochloric Acid 20.0-500 ppm 6406140 Hydrogen Cyanide†† 2.0-50.0 ppm 6406100 Hydrogen Peroxide†† 0.20-2.0 ppm 6406440 Hydrogen Sulfide 0.20-5.0 ppm 6406520 Hydrogen Sulfide* 2.0-50.0 ppm 6406050 Hydrogen Sulfide 20.0-500 ppm 6406150 Hydrogen Sulfide 100-2,500 ppm 6406220 Iso-Propanol 40.0-1,000 ppm 6406390 Mercaptan 0.25-6.0 ppm 6406360 Methanol 20.0-500 ppm 6406380 MTBE 10.0-200 ppm 6406530 Methylene Chloride†† 20.0-400 ppm 6406510 Nitrogen Dioxide* 0.50-25.0 ppm 6406120 Nitrous Fumes* 0.50-15.0 ppm 6406060 Nitrous Fumes 10.0-200 ppm 6406240 Oxygen 1.0-30.0% Vol 6406490 Ozone†† 25.0-1,000 ppb 6406430 Perchloroethylene*†† 5.0-500 ppm 6406040 Petroleum Hydrocarbons 20.0-500 ppm 6406200 Petroleum Hydrocarbons 100-3,000 ppm 6406270 Phosgene 0.05-2.0 ppm 6406340 Phosphine 0.10-2.5 ppm 6406400 Phosphine 1.0-25.0 ppm 6406410 Phosphine 20.0-500 ppm 6406420 Phosphine 200-5,000 ppm 6406500 Propane 100-2,000 ppm 6406310 Styrene 2.0-40.0 ppm 6406560 Sulfur Dioxide 0.40-10.0 ppm 6406110 Sulfur Dioxide 5.0-150 ppm 6406180 Toluene 10.0-300 ppm 6406250† Training Chip – 6406290 Trichloroethylene†† 5.0-100 ppm 6406320 Vinyl Chloride 0.30-10.0 ppm 6406170 Vinyl Chloride 10.0-250 ppm 6406230 Water Vapor 0.40-10.0 mg/L 6406450 Xylene 10.0-300 ppm 6406260† †Chips with cold storage requirement; to be stored at or below 50°F, do not freeze. ††Chips with a 6-12 month shelf life. (**)Please Note: The two Benzene chips in the CMS program have nearly the same measurement range. The primary difference is the humidity limits. The Benzene 0.5-10 ppm chip is designed for high humidity environments. Please refer to the following table. Maximum Humidity, Benzene 0.2-10 ppm Temperature °F Maximum Humidity, Benzene 0.5-10 ppm 100% 32 100% 100% 50 100% 100% 68 100% 99% 86 100% 76% 95 100% 60% 104 80% Performance Data Measuring Range & Resolution Depends on the chip type Typical Measuring Time 1-2 minutes in the range of the limit values, dependent on the chip type and the concentration of the hazardous substance Contamination Effects Not possible Calibration Not necessary Operational Temperature 34 to 104°F (0 to 40°C) Storage Temperature; Analyzer -4 to 140°F (-20 to 60°C) Storage Temperature; Chips <77°F (<25°C) Atmospheric Pressure 700 to 1,100 HpA (or Mbar) Humidity 0 to 95% relative, not condensed Determination of the Measurement Value Optics & light transfer system reflective measurement System Diagnostics Self-performing, microprocessor controlled for all components of the system Display LCD, 2 x 16 alphanumeric digits with backlight Menu Languages English, German, French, Spanish Operational Capacity Approximately 450 minutes on one set of batteries Power Source 4 x 1.5V (AA) alkaline batteries Weight 1.6 pounds (730g) Dimensions 8″ x 3.6″ x 1.7″ Approvals UL Class 1, Div. 1, Groups A, B, C, D, Temp Code T4 Protection Class Dust & water spray protection according to IP54
Manufacturer: Draeger Inc
Brand: Chip Measurement System
Model: CMS
Short Description:

The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip - start measurement-read measurement result on the LCD display. The Draeger CMS combines the advantages of Draeger Tubes with those of an optoelectronic analysis system. Two components define the system: the analyzer and the substance specific chip.